INSERT INSTRUCTIONS

The Command Access MLRK1 is a field installable motorized latch-retraction kit for:

  • MRLK1-HAG – Hager 45/4600 series devices
  • MRLK1-IDC – IDC 8000 series devices
  • MRLK1-PDQ – PDQ 6200 series devices
  • MRLK1-SQ – Stanley QED 1/2000 series devices
  • MRLK1-LAW – Lawrence 8000 series devices
  • MRLK1-LSDA1 – LSDA 9000 R/V series devices

Kit Includes

A. 1- Motor Mount w/MM5
accessories
B. 1-50944 – Molex Pigtail

C. 2-40320 – M4 x 6MM Phillips Screws

D. 1-51235 Spacer

Tools Required
Cordless Drill or Phillips Screwdriver

SPECIFICATIONS

  • Input Voltage: 24VDC +/- 10%
  • AVERAGE LATCH RETRACTION CURRENT: 900 mA
  • Average holding current: 215 ma
  • Wire gauge: Minimum 18 gauge
  • Direct wire run – no relays or access control units in-between power supply & module Recommend

Recommended Power Supplies: Use a power limited class 2 power supply
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you plan on using a non-Command power supply it must be a filtered & regulated linear power supply

Technical Information

Installation Instruction
QR Code

SETTING PUSH TO SET (PTS
IMPORTANT INFO
MAKE SURE TO SET PTS BEFORE FINISHING INSTALLATION

Step 1 – To enter PTS mode: Depress MM5 button & apply power. The device will emit 1 SHORT beep. The device is now in PTS mode.
Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3 – Continue to keep pad depressed, the device will emit 1 LONG Beep.After the beep has stopped, release the pad and now the adjustment is complete. test the new location, If not to your liking repeat the 3 steps
MM5 SWITCHES
POWER

PROGRAMMING

MM5

Troubleshooting & Diagnostics

Beeps Explanation Solution
2 Beeps Over Voltage > 30V unit will shut down. Check voltage & adjust to 24

V
3 Beeps| Under Voltage| < 20V unit will shut down. Check voltage & adjust to 24 V
4 Beeps| Failed Sensor| Verify all 3 sensor wires are installed correctly. Replace sensor if problem persists by contacting office.
5 Beeps| Retraction or dogging failure| After 1st fail: 5 beeps then immediately attempts to retract again. After 2nd fail: 5 beeps with pause in- between for 30 seconds then device attempts to retract again. After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract. To Reset: Depress bar for 5 seconds at any time

I n s ta l l at i o n I n s t r u c t i o n s

  1. Remove Head Cover from device.
    Installation Instruction

  2. Remove (2) Screws securing Housing to 2. Baserail.
    Installation Instruction

  3. Slide off Housing to expose Pushpad & 3. Baserail Assembly
    Installation Instruction

  4. Install Spacer onto connecting rod in front of the back activating bracket to increase the return spring tension. Make sure Spacer is facing the correct direction
    Installation Instruction

  5. If your device has Mechanical Dogging, flip Baserail over & remove (2) screws securing dogging to Baserail.
    Installation Instruction

  6. Push Down on Push Pad to extend connecting Rod’s Dogging Hole.
    Installation Instruction

  7. Slide Motor Kit’s Attaching Arm into Dogging Hole. Make Sure the motor kit mounting bracket is on TOP of Baserail
    Installation Instruction

  8. Flip Baserail/Pushpad over, holding motor kit in place so it stays attached. Secure Motor Kit with (2) M4 Screw provided.

  9. Slide Baserail motor side 1st back into the exit device Housing. Make sure the Motor & baserail go into the proper channels.

  10. Re-install (2) Screws securing Housing to Baserail.

  11. Set the “Push to Set Adjustment” following the steps below.
    Installation Instruction

S etting PUSH TO SET (PTS)
Important Info
Make sure to set PTS before finishing installation
MM5 SWITCHES
POWER

PROGRAMMING

MM5

Step 1 – To enter PTS mode: Depress MM5 button & apply power. The device will emit 1 SHORT beep. The device is now in PTS mode.
Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
Step 3 – Continue to keep pad depressed, the device will emit 1 LONG Beep. After the beep has stopped, release the pad and now the adjustment is complete. test the new location, If not to your liking repeat the 3 steps.