ACURITE 01118 Weather Station with Temperature, Humidity and Forecaster Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
Weather Station
model 01118
Questions? Contact Customer Support at 877-221-1252 or visit www.AcuRite.com.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display with Fold-Out Stand
- Outdoor Sensor
- Instruction Manual
- Power Adapter
Features & Benefits
OUTDOOR SENSOR
-
Integrated Hanger
For easy placement. -
Wireless Signal Indicator
Flashes when data is being sent to the display. -
Battery Compartment
-
A-B-C Switch
ID code that must match display’s A-B-C switch to ensure units synchronize. -
Battery Compartment Cover
FRONT OF DISPLAY
-
Outdoor Sensor Signal Strength
-
Sensor Low Battery Indicator
-
Current Outdoor Temperature
The arrow icon indicates the direction temperature is trending. -
Current Barometric Pressure
The arrow icon indicates the direction the pressure is trending. -
Current Indoor Temperature
-
Clock
-
∧ and ∨ Buttons
For setup preferences. -
°F/°C Butto n
For selecting temperature units. -
SET Button
For setup preferences. -
Button
For momentary backlight and dimmer settings. -
Date
-
Current Indoor Humidity
-
12 to 24 Hour Weather Forecast
Self-calibrating forecasting pulls data from the outdoor sensor to generate your personal forecast. -
Learning Mode Icon
Disappears after weather forecast self-calibration is complete. -
Current Outdoor Humidity
The arrow icon indicates the direction humidity is trending. -
Icon
Indicates display is in auto-dimming brightness mode (see page 7).
BACK OF DISPLAY
-
Integrated Hang Hole
For easy wall mounting. -
RESET Button
For full reset to factory defaults. -
Backup Battery Compartment
-
Fold-out Tabletop Stand
-
Power Adapter
-
Plug-in for Power Adapter
-
A-B-C Switch
ID code that must match sensor’s A-B-C switch to ensure units synchronize. -
Battery Compartment Cover
(not shown)
SETUP
Sensor Setup
-
Set the A-B-C Switch
The A-B-C switch is located inside the battery compartment. It can be set to A, B or C. However, you must select the same letter choices for both the sensor and the display in order for the units to synchronize. -
Install or Replace Batteries
AcuRite recommends high quality alkaline or lithium batteries for the best product performance. Heavy-duty or rechargeable batteries are not recommended.
The sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4ºF / -20ºC.
1. Slide off the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment.
2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover.
Display Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C.
You must select the same letter choices for both the display and the sensor in order for the units to synchronize. -
Install or Replace Backup
Batteries (optional)
1. Remove the battery compartment cover.
2. Insert 3 x AAA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/–) diagram in the battery compartment.
3. Replace the battery cover. -
Plug-in Power Adapter
For the best performance, plug in the power adapter as the main power source for this product.
IMPORTANT: Batteries are a backup power source to preserve records in the event of a power outage. The power adapter is recommended as the primary power source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device
prior to battery installation. Remove batteries from equipment that will not
be used for an extended period of time. Follow the polarity (+/-) diagram in
the battery compartment. Promptly remove dead batteries from the device.
Dispose of used batteries properly. Only batteries of the same or equivalent
type as recommended are to be used. DO NOT incinerate used batteries. DO NOT
dispose of batteries in free, as batteries may explode or leak. DO NOT mix old
and new batteries or types of batteries (alkaline/standard). DO NOT use
rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT
short-circuit the supply terminals.
Set the Time, Date & Units
Press and release the “SET” button, located on the front of the display, to
enter SET MODE. Once in set mode, the preference you are currently setting
will blink on the display.
To adjust the currently selected (flashing) item, press and release the ∧
and ∨ buttons (press and HOLD to fast adjust).To save your adjustments,
press and release the “SET” button again to adjust the next preference. The
preference set order is as follows:
AUTO CHANGE for DST? (Daylight Saving Time Y or N)
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
BAROMETRIC PRESSURE UNITS (hPa or inHg)
If you live in an area that observes Daylight Saving Time, DST should be set to Y, even if it is not currently Daylight Saving Time.
You will automatically exit the SETUP MODE if no buttons are pressed for 10
seconds. Enter setup mode at any time by pressing the “SET” button.
Select Degrees Fahrenheit or Celsius
To select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units,
press the “ºF/ºC” button located on the front of the display.
Display Backlight Settings
This weather station’s color display features three different lighting
settings:
High (100%) brightness, Medium (60%) brightness, and Low (30%) brightness.
When the display is powered with the power adapter, the backlight remains on
at 100% brightness. Press the button once to dim to 60% brightness; press
again to dim to 30%, press a third time to enter AUTO-DIM mode. “ ” will
appear above the current outdoor humidity reading.
AUTO DIM MODE: Automatically adjusts display brightness based on time of
day.
6:00 a.m. – 9:00 p.m. = 100% brightness
9:01 p.m. – 5:59 a.m.= 30% brightness
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display and the outdoor sensor is critical to the
accuracy and performance of this product.
Display Placement
Place the display in a dry area free of dirt and dust. Display stands upright
for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensors must be placed outside to observe outdoor conditions.
The sensor is water-resistant and is designed for general outdoor use,
however, to extend its life place the sensor in an area protected from direct
weather elements.
Hang the sensor using the integrated hang holes or hanger, or by using string
(not included) to hang it from a suitable location, like a well-covered tree
branch. The best location is 4 to 8 feet (1 to 2 meters) above the ground with
permanent shade and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- Display and outdoor sensors must be within 330 ft (100 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
The sensor will now synchronize with the display. It may take a few minutes
for synchronization to complete. Please refer to the troubleshooting section
of this manual if anything appears to be functioning improperly.
OPERATION
Using the Weather Station
Learning Mode
Self-calibrating forecasting uses a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the Learning Mode icon disappears from the display screen. At
this point, the self-calibrated pressure is tuned in to your location and the
unit is ready for superior weather prediction.
Weather Forecast
AcuRite’s patented self-calibrating forecasting provides your personal
forecast of weather conditions for the next 12 to 24 hours by collecting data
from the sensor in your backyard. It generates a forecast with pinpoint
accuracy – personalized for your exact location.
View the complete list of icons at www.AcuRite.com/acurite-
icons
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This
weather station displays the current pressure with an arrow icon to indicate
the direction the pressure is trending (FALLING, STEADY, or RISING).
Troubleshooting
Problem | Possible Solution |
---|
No outdoor sensor reception
no bars| If the wireless signal indicator shows no bars:
•Relocate the display and/or the outdoor sensor. The units must be within 330
ft (100 m) of each other.
•Make sure both units are placed at least 3 feet (.9 m) away from electronics
that may interfere with the wireless communication (such as TVs, microwaves,
computers, etc.).
•Use standard alkaline batteries (or lithium batteries in the sensor when the
temperature is below -4°F/-20°C). Do not use heavy-duty or rechargeable
batteries.
NOTE: It may take a few minutes for the display and sensor to synchronize
after batteries are replaced.
Outdoor temperature is flashing or showing dashes| Flashing of the outdoor
temperature is generally an indication of wireless interference.
1. Bring both the sensor and display indoors and remove batteries/power
adapter from each.
2. Make sure the A-BC switches on both units match.
3. Reinstall batteries in the outdoor sensor.
4. Reinstall batteries/power adapter in the display.
5. Let the units sit within a couple of feet of each other for a few minutes
to gain a strong connection.
Inaccurate forecast| •Weather Forecast icon predicts conditions for the next
12 to 24 hours, not current conditions.
•Has the Learning Mode icon disappeared from the display? Learning Mode must
complete before forecast and pressure will be accurate.
•Allow the unit to run continuously for 33 days. Battery removal or resetting
the display will restart Learning Mode. After 14 days, the forecast should be
fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity| •Make sure both the display and sensor
are placed out of direct sunlight and away from any heat sources or vents (see
page 8).
•Make sure both units are positioned away from moisture sources (see page 8).
Display screen not working| •Check that the power adapter is plugged into the
display and an electrical outlet.
•Reset the display by pressing the reset button, located on the bad( of the
display. The date and time will need to be entered after a reset.
If your AcuRite product does not operate properly after trying the
troubleshooting steps, visit www.AcuRite.com or call
877-221-1252 for assistance.
Care and Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt, and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Calibration
The indoor/outdoor temperature and humidity readings, and barometric pressure
can be calibrated on the display unit to improve accuracy. Calibration can
improve accuracy when sensor placement or environmental factors impact the
data accuracy.
- To access calibration mode, press AND HOLD the “ ∧ ” or SET,” and “ V ” buttons simultaneously for at least 5 seconds.
- To adjust the currently selected (flashing) item, press and release the “ ∧ ” or “ V ” buttons to calibrate the data value higher or lower than the actual reading.
- To save your adjustments, press and release the “SET” button to adjust the next preference. The “ ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)
To change from AUTO to MANUAL pressure mode and vice versa, press
AND HOLD the “SET” button for 10 seconds. “pressure” will disappear below the
barometric pressure to indicate that manual mode has been activated.
Press and HOLD the “SET” button for 10 seconds to return to AUTO mode.
After 10 seconds of inactivity, the display will save the adjustments and exit
calibration mode. Note: Calibrations will be erased if the display is reset or
if batteries are removed and the power adapter is unplugged.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGE| 1% to 99% RH
WIRELESS RANGE| 330 ft/100 m depending on home construction materials
OPERATING FREQUENCY| 433 MHz
POWER| Display: 5V, 100mA power adapter 3 x AAA alkaline batteries (optional)
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING| Outdoor: 16 second updates
Indoor: 60-second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur n a particular installation. If his equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increasetheseparationbetween the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
Visit us at www.AcuRite.com
Limited 1-Year Warranty
AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For
purchases of AcuRite products, AcuRite provides the benefits and services set
forth herein. For purchases of Chaney products, Chaneprovides the benefits and
services set forth herein.
We warrant that all products we manufacture under this warranty are of good
material and workmanship and, when properly installed and operated, will be
free of defects for a
period of one year from the date of purchase.
Any product which, under normal use and service, is proven to breach the
warranty contained herein within ONE YEAR from the date of sale will, upon
examination by us, and at ur sole option, be repaired or replaced by us.
Transportation costs and charges for returned goods shall be paid for by the
purchaser. We hereby disclaim all responsibility for such transportation costs
and charges. This warranty will not be breached, and we will give no credit
for products that have received normal wear and tear not affecting the
functionality of the product, been damaged (including by acts of nature),
tampered, abused, improperly installed, or repaired or altered by others than
our authorized representatives. Remedy for breach of this warranty is limited
to repair or replacement of the defective item(s). If we determine that repair
or replacement is not feasible, we may, at our option, refund the amount of
the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
We expressly disclaim all liability for special, consequential, or incidental
damages, whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply
to you. We further disclaim liability from personal injury relating to our
products to the extent permitted by law. By acceptance of any of our products,
the purchaser assumes all liability for the consequences arising from their
use or misuse. No person, firm or corporation is authorized to bind us to any
other obligation or liability in connection with the sale of our products.
Furthermore, no person, firm, or corporation is authorized to modify or waive
the terms of this warranty unless done in writing and signed by a duly
authorized agent of ours. In no case shall our liability for any claim
relating to our products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy apply only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United
States and the State of Wisconsin. Any dispute relating to this Policy shall
be brought exclusively the federal or state courts having jurisdiction in
Walworth County, Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark
of the
Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and
copyrights are the property of their respective owners.
AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.
01118 INST 082917
Printed in China
Documents / Resources
|
ACURITE 01118 Weather Station with Temperature, Humidity and
Forecaster
[pdf] Instruction Manual
01118, Weather Station with Temperature Humidity and Forecaster
---|---
References
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- Icon Definitions and Terminology | AcuRite
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>