- INSERT INSTRUCTIONS
- Kit Includes
- Tools Required
- SPECIFICATIONS
- Technical Information
- Setting PUSH TO SET (PTS)
- Troubleshooting & Diagnostics
- Installation Instructions
- Setting PUSH TO SET (PTS)
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COMMAND ACCESS TECHNOLOGIES MLRK1-HAG Motorized Latch Retraction Kit
INSERT INSTRUCTIONS
The Command Access MLRK1 is a field installable motorized latch-retraction kit for:
- MRLK1-HAG – Hager 45/4600 series devices
- MRLK1-IDC – IDC 8000 series devices
- MRLK1-PDQ – PDQ 6200 series devices
- MRLK1-SQ – Stanley QED 1/2000 series devices
- MRLK1-LAW – Lawrence 8000 series devices
- MRLK1-LSDA1 – LSDA 9000 R/V series devices
Kit Includes
- 1- Motor Mount w/MM5
- 1- 50944 – Molex Pigtail
- 1- 50030 – 6’ Lead w/ VD Connector
- 2- 40320 – M4 x 6MM Phillips Screws
- 1- 51235 Spacer
Tools Required
- Cordless Drill or Phillips Screwdriver
SPECIFICATIONS
- Input Voltage: 24VDC +/- 10%
- AVERAGE LATCH RETRACTION CURRENT: 900 mA
- Average holding current: 215 ma
- Wire gauge: Minimum 18 gauge
- Direct wire run – no relays or access control units in-between power supply & module
Optional built-in rex
- SPDT – Rated .5a @24V
- green= Common (C)
- Blue = normally open (NO)
- grey = normally closed (NC)
Recommended Power Supplies: Use a power limited class 2 power supply
All Command Access exit devices & field installable kits have been thoroughly
cycle tested with Command Access power supplies at our factory. If you plan on
using a non-Command power supply it must be a filtered & regulated linear
power supply.
Technical Information
Setting PUSH TO SET (PTS)
Important Info
Make sure to set PTS before finishing installation
- Step 1 – To enter PTS mode: Depress MM5 button & apply power. The device will emit 1 SHORT beep. The device is now in PTS mode.
- Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
- Step 3 – Continue to keep pad depressed, the device will emit 1 LONG Beep. After the beep has stopped, release the pad and now the adjustment is complete. test the new location, If not to your liking repeat the 3 steps.
Troubleshooting & Diagnostics
Beeps | Explanation | Solution |
---|---|---|
2 Beeps | Over Voltage | > 30V unit will shut down. Check voltage & adjust |
to 24 V.
3 Beeps| Under Voltage| < 20V unit will shut down. Check voltage &
adjust to 24 V.
4 Beeps| Failed Sensor| Verify all 3 sensor wires are installed
correctly. Replace sensor if problem persists by contacting office.
5 Beeps| ****
Retraction or dogging failure
| After 1st fail: 5 beeps then immediately attempts to retract again.
After 2nd fail: 5 beeps with pause in-between for 30 seconds then device
attempts to retract again.
After 3rd fail: 5 beeps every 7 minutes, device will not attempt to retract.
To Reset: Depress bar for 5 seconds at any time.
Installation Instructions
-
Remove Head Cover from device.
-
Remove (2) Screws securing Housing to 2. Baserail.
-
Slide off Housing to expose Pushpad & 3. Baserail Assembly.
-
Install Spacer onto connecting rod in front of the back activating bracket to increase the return spring tension. Make sure Spacer is facing the correct direction.
-
If your device has Mechanical Dogging, flip Baserail over & remove (2) screws securing dogging to Baserail.
-
Push Down on Push Pad to extend connecting Rod’s Dogging Hole.
-
Slide Motor Kit’s Attaching Arm into Dogging Hole. Make Sure the motor kit mounting bracket is on TOP of Baserail.
-
Flip Baserail/Pushpad over, holding motor kit in place so it stays attached. Secure Motor Kit with (2) M4 Screw provided.
-
Slide Baserail motor side 1st back into the exit device Housing. Make sure the Motor & baserail go into the proper channels.
-
Re-install (2) Screws securing Housing to Baserail.
-
Set the “Push to Set Adjustment” following the steps below.
Setting PUSH TO SET (PTS)
Important Info
Make sure to set PTS before finishing installation
- Step 1 – To enter PTS mode: Depress MM5 button & apply power. The device will emit 1 SHORT beep. The device is now in PTS mode.
- Step 2 – While depressing the push pad, apply power. (i.e. presenting the credential to the reader).
- Step 3 – Continue to keep pad depressed, the device will emit 1 LONG Beep. After the beep has stopped, release the pad and now the adjustment is complete. test the new location, If not to your liking repeat the 3 steps.
US customer support
1-888-622-2377
www.commandaccess.com
CANADA customer support
1-855-823-3002
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>