COMMAND ACCESS “DL20” Door Loops
Mounting Instructions
- Locate the centerline of the door loop on the underside of the Exit Device Housing 4” from the soffit of the frame and 1” from the face of the door
- Locate the centerline of the door loop for the face of frame 2” down from the edge of the Exit Device
- Drill pilot holes (#24 drill) to mount the base and a 5/8” hole for wire conduit.
- Mount base using #10 SMS.
- Thread electrical wires through the door loop.
- Install covers with #8 SMS screws
NOTES:
Maximum electrical wires: 7 ea. 18 awg, 10 ea. 22 awg Door Loop flexible
conduit can be field cut
Door Loop Base Dimensions