CASPR TECHNOLOGIES CASPR COMPACT Portable Air and Surface Purification System Owner’s Manual

May 15, 2024
CASPR TECHNOLOGIES

CASPR TECHNOLOGIES CASPR COMPACT Portable Air and Surface Purification

System

CASPR-TECHNOLOGIES-CASPR-COMPACT-Portable-Air-and-Surface-Purification-
System-PRODUCT

Specifications

  • Model: CASPR COMPACT
  • Effective Range: 4-7 feet
  • Power Source: Standard wall outlet
  • Remote Control: Battery-operated
  • Modes: Standard, High, Away

Product Usage Instructions

Initial Setup

  1. Place the CASPR COMPACT unit 4-7 feet off the ground with at least 6 inches of clearance behind for airflow.
  2. Position the unit towards the center of the area to be protected.
  3. Ideally, place the unit across the room from an AC intake or return vent for optimal air circulation.
  4. Plug the power cable into a standard wall outlet and connect the other end to the rear of the unit.
  5. Insert the battery into the remote control.
  6. Power on the unit using either the remote control or the power button on the display screen.

Modes of Operation

  • Standard Mode: The default mode for occupied rooms. Fan speed can be adjusted using the unit or remote control.
  • High Mode: This mode does not produce ozone and functions similarly to Standard Mode.
  • Away Mode: Intended for use when away from the space, but since the unit does not produce ozone, it operates like Standard Mode.

FAQ

Q: Where can I purchase replacement parts for my CASPR COMPACT unit?

  • A: Replacement parts can be obtained from authorized distributors or directly from CASPR Technologies at www.casprtech.com.

Q: What should I do if I have questions about my unit’s operation?

  • A: For any operational inquiries, please reach out to your distributor or contact CASPR Technologies directly for assistance.
  • CAUTION: Read the manual carefully for proper procedures and operations

Congratulations!

  • On your decision to protect the people you care about with CASPR.
  • Your COMPACT unit can provide years of trouble-free disinfection and protection. Some parts of your CASPR COMPACT will need to be replaced periodically.
  • Replacement parts can be purchased from your authorized distributor or directly from CASPR Technologies at www.casprtech.com

Initial set up

  1. For your most ideal effectiveness, place CASPR COMPACT unit 4-7 feet off the ground ensuring there is a minimum of 6 inches behind the unit to allow for proper airflow.
  2. Face the unit towards the center of the area you are protecting.
  3. Ideally, your placement of the unit would be across the room from an AC intake or return vent. (The vent takes air OUT of your room and back up to the AC unit) This allows your normal airflow to circulate the disinfecting oxidizing molecules across the entire room. The best practice would be to NOT place your unit directly under or next to the intake or return air vent.
  4. Plug the power cable into any standard wall outlet and plug the other end of the power cable into the rear of the COMPACT unit.
  5. Insert the battery inside the remote control.
  6. Power on the unit by either using the remote control or manually pushing the power button on the left side of the display screen.
  7. STANDARD MODE: You will know your unit is running in standard mode when the display screen is lit up and you see either PCO or NCC (depending on what date you purchased your unit) This is your standard 24/7 mode for occupied rooms. Fan speed can be set higher or lower by the up or down arrows on the unit or remote control.
  8. HIGH MODE: Your unit has the ozone-producing plate removed before shipping. This mode will not produce any ozone.
  9. The High Mode on your unit will have the same effect as your Standard Mode.
    • Note: When the purification plate has been removed your unit will remain in Standard PCO/NCC Mode regardless of what mode is displayed on screen and can always be used in occupied spaces.
    • Any questions please contact your distributor or the CASPR company directly.
  10. AWAY MODE: The Away Mode was designed to produce a small amount of ozone and to be used when you are AWAY from space. HOWEVER, your unit has the ozone-producing plate removed. This Away mode will therefore not produce any ozone.
  11. The Away Mode on your unit will have the same effect as your Standard Mode.
  12. Since your unit has the ozone-producing plates removed, ANY mode your unit is on will be in effect the same as the Standard Mode.
    • SLEEP MODE: This mode is found on the remote control only and simply dims the front screen at nighttime if the unit is in your bedroom. This does not affect the disinfection effectiveness or functionality of the unit.

Warnings

  • Review this list before using or performing any maintenance or cleaning of your unit.
  • WARNING: Never operate the unit near a heat source, open flame, or flammable/combustible fluids.
  • WARNING: Do not operate the unit unless all parts (including the Cell, Purification Plate, Rear Filter Assembly, and Rear Cover) are properly installed.
  • CAUTION: Directly viewing the lamp inside the unit for an extended period may result in eye damage.
  • CAUTION: The unit should be powered OFF and the Power Cord should be disconnected when Cleaning/Disassembling/ Reassembling/Servicing.
  • Note: When the purification plate has been removed your unit will remain in the Standard
  • PCO/NCC Mode regardless of what mode is displayed on screen can always be used in occupied spaces. Any questions please contact your distributor or the CASPR company directly.

Additional Information

  • Each CASPR COMPACT can effectively treat 1,500 square feet of space if there is air circulation in the space. Ensure doors remain open in rooms you are trying to disinfect.
  • A best practice is to face your COMPACT unit towards the largest open space you are disinfecting so it can efficiently process and circulate the air in the area. Unlike the friendly ghosts, CASPR cannot penetrate or go through walls.
  • Never place an operating unit on the floor unless you are specifically trying to disinfect an area on the floor. The goal is to disinfect and circulate the air you breathe which is obviously in the space 4-8 feet above the floor.
  • Your CASPR COMPACT comes with a remote control, and one CR2025 battery, for easier operation when the unit is placed in a location that is not easily accessible by manually pushing the buttons.

Routine Maintenance

  • Good news…You have very little maintenance with your new CASPR unit. Every 60-90 days check to see if you need to clean or dust the front grill.
  • If the front grill is dusty, it is likely, the rear Filter Assembly also needs to be cleaned.
  • A vacuum, compressed air, or a small clean dry paintbrush all work well to remove dust.
  • This is a WASHABLE and REUSABLE filter. In a high-dust environment, you may need to clean the filter monthly. In a very low-dust environment, you might clean it every 90 days or so.
  • The NCC CELL should be replaced once every two years.

Removing and Cleaning the Filter Assembly

  1. Turn off the unit by pressing the Power button.
  2. Unplug the unit from the power source and then remove the power cord from the back of the unit.
  3. Unscrew and remove the Rear Cover screw located above the Power Cord Port on the rear of the unit. If your unit does not have a screw, then move to the next step.
  4. Place one hand on the right and left side of the Rear Cover, slide the rear cover upwards, and lift it away from the machine.
  5. Wipe the rear cover with a damp cloth and set it to the side.
  6. Grasp the sides of the filter, lift slightly, and pull the filter away from the unit.
  7. Typically, you should only need to vacuum (brush attachment works best) the dirt from the filter. If the filter is still dirty internally once you have tried vacuuming and brushing, you should thoroughly rinse the filter with warm water. Always shake excess water from the filter and LET IT DRY completely before reattaching the filter to the rear of the unit.

Reattaching the Filter

  1. Gently lay the filter back onto the machine with the diamond pattern facing the rear of the unit and the honeycomb pattern facing the front of the unit.
  2. Replace the Rear Cover by sliding it from the top of the unit towards the bottom to secure the filter in place. You will know it is in place when you hear a “Click”
  3. Replace and gently tighten the screw on the Rear Cover if your unit has a screw, and plug the unit back into the power source. You are good to go!

Replacing the NCC Cell (every 2 years)

  1. Turn off the unit by pressing the Power button.
  2. Unplug the unit from the power source and then remove the power cord from the back of the unit.
  3. Unscrew and remove the Rear Cover screw located above the Power Cord Port on the rear of the unit.
  4. Place one hand on the right and left side of the Cover, slide the rear cover upwards towards the top of the unit, and lift it away.
  5. Remove the filter assembly.
  6. Unscrew the cell nuts.
  7. Unplug the cell power cable.CASPR-TECHNOLOGIES-CASPR-COMPACT-Portable-Air-and-Surface-Purification-System-FIG-8
  8. Pull the NCC cell away from the unit and attach the new NCC cell.
  9. Reinsert the two screws to secure the new cells. assembly.
  10. Reconnect the new power cable.
  11. Replace the Rear Cover by sliding it from the top of the unit towards the bottom to secure the filter in place. You will know it is in place when you hear a “Click”
  12. Replace and gently tighten the screw on the Rear Cover and plug the unit back into the power source. Do not over-tighten. You are good to go!

Removing and Cleaning the Front Grille

  1. Locate the Front Grille Screw on the front of the machine above the CASPR logo.
  2. Using your screwdriver, carefully remove the Front Grille Screw and place the screw where you will easily find it later.
  3. Remove the Front Grille by pushing up from the bottom of the Front Grille with your fingers. Be careful to ensure the Ionization Needle (in the top center of the front of the unit) is not damaged.
  4. Clean the Front Grille using (compressed air, vacuum cleaner, damp cloth, or warm soapy water) and set the Front Grille aside.
  5. If the Ionization Needle is visibly dusty, gently clean it with a cotton swab and clear alcohol-based cleaner or rubbing alcohol.

Reattaching the Front Grille

  1. Align the Front Grille to the front of the unit, being careful not to damage the Ionization Needle at the top center of the unit.
  2. Insert and gently tighten the screw.
  3. You are good to go!

Troubleshooting

Has your unit failed to turn on?

  1. Verify that the Power Plug is plugged into an operational wall outlet.
  2. Ensure that the Power Cord is fully inserted (leaving less than a 1/8”) into the Power Adapter.
  3. Ensure that the Power Adapter Plug is fully seated in the round Power Cord Port on the back of the unit. Remove and reinstall to verify.
  4. Verify the Power Button has been activated on the Control Panel.
  5. If the Power Button on the Control Panel fails, try using the Power Button on your Remote Control. If the Control Panel fails, contact your distributor or CASPR Technologies (www.casprtech.com).
  6. If none of the above items resolve the issue you may need to contact your distributor or CASPR technologies and request a new purification plate.

Note: Your unit does not include purification plates. These versions will remain in Normal PCO/NCC Mode regardless of what mode is displayed on the screen. If you don’t have a purification plate in your unit then it cannot produce ozone in any mode.

The Cell Does Not Light Up

  1. Ensure the Cell Power Connector is properly seated in the Cell Power Connector Outlet.
    • a) Follow the instructions for removing the Rear Cover and Filter Assembly.
    • b) Check to see if the Cell Power Connector is properly inserted in the Cell Power Connector Outlet. To ensure the proper connection, gently push until the tabs at the top and bottom of the Cell Power Connector snap into place, securing it to the Cell Power Connector Outlet.
  2. If the Cell still fails to operate, it needs to be replaced. Contact your distributor or CASPR (www.casprtech.com).

Warranty Information

  • LIMITED 3-YEAR WARRANTY ON CASPR TECHNOLOGIES UNITS AND 1-YEAR WARRANTY ON CASPR TECHNOLOGIES REPLACEMENT PARTS
  • Customers should not repackage and ship the CASPR Compact unit due to the possibility of irreparable damage.
  • For warranty service, please contact your CASPR TECHNOLOGIES Distributor for the address of the nearest service center, email [email protected] call Customer Service at 844-717-8819.

WHAT IS COVERED BY THIS WARRANTY?

  • We warrant the CASPR Compact to the Customer, subject to the conditions below, against defects in workmanship or material, provided that the products are returned to a service location within three (3) years from the date of purchase.

INSTALLATION AND MAINTENANCE REQUIREMENTS

  • This warranty is expressly conditioned upon proper installation, operation, cleaning, and maintenance, all by the Owner’s Manual.
  • Failure to meet any of these requirements will void this warranty. Servicing of your CASPR Compact by parties other than our authorized representatives and/or using parts other than genuine parts will also void this warranty.

HOW TO OBTAIN WARRANTY SERVICE

  • Customer must contact their CASPR Technologies Distributor and provide proof of purchase within the above periods.
  • We will repair replace and return the product, without charge and within a reasonable period, subject to the conditions herein, if its examination shall disclose any part to be defective in workmanship or material.
  • If we, at our discretion, are unable to repair the product after a reasonable number of attempts, we will provide either a refund of the purchase price or a replacement unit, at the company’s option.

WHAT IS NOT COVERED BY THIS WARRANTY

  • Ordinary wear and tear shall not be considered a defect in workmanship or material.
  • These warranties do not apply to filters nor for loss or damage caused by accident, fire, abuse, misuse, improper installation, leaking, modification, misapplication, or by any repairs other than those provided by our authorized Service Center.
  • This warranty is non-transferable.

MISSING SERIAL NUMBERS AND UNAUTHORIZED CHANNELS

  • If a valid serial number is missing from the product, the warranty will be voided. CASPR Technologies products are authorized for sale through CASPR Technologies Distributors only.
  • Warranties are voided if a product is purchased through unauthorized channels; this includes websites that are not authorized to use CASPR Technologies’ trademarked names, images, and logos as well as Internet auction sites (e.g. eBay and Craigslist).
  • To confirm warranty coverage before purchasing a product, contact CASPR Technologies at 844-717-8819 with the serial number located on the back of the unit.
  • EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN, WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND. ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
    LIMITATION OF LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES WE SHALL NOT, IN ANY CASE, BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM BREACH OF EXPRESSED OR IMPLIED WARRANTIES, CONDITIONS, GUARANTEES OR REPRESENTATIONS, BREACH OF CONTRACT, NEGLIGENCE, OR ANY OTHER LEGAL THEORY. Such excluded damages include but are not limited to, loss of profits or revenue, and loss of the use of the products, and any loss caused by leaks or other water damage.

FOR U.S. APPLICATION ONLY

  • This warranty gives you specific legal rights, and you may also have other rights which vary from state
    to state. Some states do not allow limitations on warranties or remedies for breaches. In such states, the above limitations may not apply to you.

FOR CANADIAN APPLICATION ONLY

  • Exclusion of Subsequent Owners: Except as otherwise required by applicable legislation, this warranty is not transferable. This warranty gives you specific legal rights and you may also have other rights which vary from province to province. Some provinces and territories do not allow limitations on warranties or remedies for breach. In such provinces or territories, the above limitations may not apply to you. If any provision of this warranty or part thereof is held by a court of competent jurisdiction to be invalid, illegal, or unenforceable, the validity, legality, and enforceability of the remaining provisions or parts thereof will not in any way be affected or impaired within the jurisdiction of that court. This entire warranty shall continue to be valid, legal and enforceable in any jurisdiction where a similar determination has not been made.
    This warranty is provided by CASPR Technologies, Inc.  4505 Excel Parkway,

    600 Addison, TX 75001

SERVICE

  • Every effort is made to ensure customers receive an up-to-date instructions manual on the use of our products; however, from time to time, modifications to our products may without notice make the information contained herein subject to alteration. For the latest information, please visit our website.
  • This warranty remains active for units sold without purification plates if removed by the manufacturer.

Diagrams

CASPR-TECHNOLOGIES-CASPR-COMPACT-Portable-Air-and-Surface-Purification-
System-FIG-10 CASPR-TECHNOLOGIES-CASPR-COMPACT-Portable-Air-and-Surface-
Purification-System-FIG-11

(Controls)

CASPR-TECHNOLOGIES-CASPR-COMPACT-Portable-Air-and-Surface-Purification-
System-FIG-12

Specifications

UNIT

  • Size: 13” high x 8.75” wide x 10.75” deep Weight: 10.2 lb.
  • Decibel (dba): 61 / Coverage: 1500 ft2

POWER CORD

  • Fuyuang Switching Power Supply
    Model Number: FY3803000

  • Input: 100-240VAC 50/60Hz 2.5A Output: 38VDC 3A

  • See the power supply label for certifications and warnings.

CELL

  • Normal Mode Output

PURIFICATION PLATE

  • Your unit does not contain a purification plate.

IONIZATION NEEDLE

  • 24 to 30 KV, 20-30 Khz Ion Generation Pulsator 6 KV DC Needle Ion Generator CASPR Technologies declines all responsibility for all damages arising from improper use of the unit or in case of tampering with the unit.
  • WWW.CASPRGROUP.COM

Documents / Resources

| CASPR TECHNOLOGIES CASPR COMPACT Portable Air and Surface Purification System [pdf] Owner's Manual
CASPR COMPACT Portable Air and Surface Purification System, CASPR COMPACT, Portable Air and Surface Purification System, Air and Surface Purification System, Surface Purification System, Purification System, System
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CASPR TECHNOLOGIES User Manuals

Related Manuals