CASPR TECHNOLOGIES CASPR Pro 400 HVAC Air and Surface Purifier Owner’s Manual
- June 17, 2024
- CASPR TECHNOLOGIES
Table of Contents
- CASPR TECHNOLOGIES CASPR Pro 400 HVAC Air and Surface Purifier
- Product Usage Instructions
- IMPORTANT SAFETY INSTRUCTIONS
- Specifications
- Product Contents
- Installation Hardware
- Electrical Requirement
- Installation Requirement
- Orientation and Airflow
- Installation Instructions
- Alternative Cutting Method
- Hardwire Instructions
- Indicator Lights
- Maintenance
- Changing the NCC Cell
- Warranty Information
- Troubleshooting Q&A
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CASPR TECHNOLOGIES CASPR Pro 400 HVAC Air and Surface Purifier
Specifications
Unit | Coverage Size (HxWxD) | Weight | Watts | Amps DC 24V | Amps AC 120V |
---|---|---|---|---|---|
CASPR Pro 400 | 4,000 ft³ | 9.75 x 9.75 x 8 | 3.0 lb | 8 | 0.52 |
CASPR Pro 1000 | 10,000 ft³ | 9.75 x 9.75 x 11 | 3.1 lb | 10 | 0.64 |
CASPR Pro 2500 | 25,000 ft³ | 9.75 x 9.75 x 16.75 | 3.3 lb | 18 | 1.0 |
CASPR Pro 5000 | 50,000 ft³ | 10 x 11.3 x 16.75 | 5.0 lb | 36 | 2.0 |
Product Contents
- NCC Cell Mounting Bracket
- Ballast Housing
- Power supply (Hardwired)
- Power supply (Plug-in)
- Installation Hardware
- (8) #8 3/4 Hex Self-tapping Screws
- (4) Flange Nuts
- (2 or 4) Cell Mounting Screws (2 screws per NCC Cell)
Replacement Parts
The NCC Cell and bulb should be replaced every 18-24 months.
Please contact your distributor for new replacements.
- CASPR Pro 400 NCC Cell Part Number: CELL-HV-5-001-AP
- CASPR Pro 1000 NCC Cell Part Number: CELL-HV-9-001-AP
- CASPR Pro 2500 and 5000 NCC Cell Part Number:CELL-HV-14-001-AP
Recommended Installation Tools
- A – 4 Hole Saw Bit
- B – 3/8 Drill Bit
- C – Drill/Power Driver
Product Usage Instructions
Safety Instructions:
WARNING!
- UV light in operation. Disconnect unit from power supply before servicing. Failure to follow warnings may result in severe eye damage.
- Unit should be mounted at least 24 inches from the heat exchanger or heating element. Placing the photocatalytic cell too close to the heating element can cause the photocatalytic matrix to combust.
To reduce the risk of electric shock, this equipment may have a grounding type plug that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the plug does not fit into the outlet, contact an HVAC professional to install the proper outlet. Do not alter the plug in any way.
Installation Instructions:
- Identify a suitable location in the central HVAC duct system for mounting the CASPR PRO unit.
- Ensure proper clearance from heat sources as per safety instructions.
- Mount the NCC Cell using the provided mounting bracket and screws.
- Connect the power supply following the installation guidelines provided.
- Secure all connections and ensure the unit is properly mounted and fixed in place.
Maintenance Instructions:
Regularly check and replace the NCC Cell and bulb every 18-24 Nmonths to
ensure optimal performance of the disinfection system.
Frequently Asked Questions (FAQ)
Q: How often should I replace the NCC Cell and bulb?
A: The NCC Cell and bulb should be replaced every 18-24 months for
effective operation of the CASPR PRO unit.
Q: Where can I purchase genuine CASPR Technologies replacement parts?
A: Genuine CASPR Technologies replacement parts are available from your
CASPR Technologies Distributor. Contact them for purchasing information.
PRo Owner’s Manual
The information in this manual is applicable to these HVAC units:
CASPR Pro 400 | CASPR Pro 1000 | CASPR Pro 2500 | CASPR Pro 5000
CAUTION: Read manual carefully for proper procedures and operation.
Congratulations on your purchase of a CASPR Technologies enhanced air and
surface disinfection system. This unit is designed to be mounted into central
HVAC duct systems.
Please read and follow all safety warnings and service procedures outlined in
this manual. Use only genuine CASPR Technologies replacement parts available
from your CASPR Technologies Distributor.
If you have any questions concerning this or any CASPR Technologies product,
contact your CASPR Technologies Distributor.
Principles of Operation
CASPR PRO uses Natural Catalytic Conversion (NCC) to generate safe, low levels
of hydrogen peroxide. NCC technology replicates natural purifying processes by
using a high intensity light to activate a proprietary metal catalytic
coating, converting water vapor into hydrogen peroxide. Hydrogen peroxide acts
as an oxidizer inactivating surface and air pathogens. It can compromise
cellular integrity by disrupting cell walls, or internal molecular structures,
rendering contaminants harmless.
To learn more about this and other CASPR Technologies products, please visit
our website at www.CASPRtech.com.
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be taken.
READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT
WARNING!
To reduce the risk of fire, electrical shock, or injury:
-
Use only as described in this manual.
-
Do not attempt to repair or adjust any of the electrical or mechanical functions.
Contact Customer Service for service information. -
Do not use outdoors or on wet surfaces.
-
Do not allow to be used as a toy. Do not allow children around the unit.
-
Do not handle with wet hands.
-
Do not touch NCC bulb with bare hands.
Specifications
Unit| Coverage| **Size (HxWxD)*| Weight| Watts| Amps
DC 24V| Amps AC 120V**
---|---|---|---|---|---|---
CASPR Pro 400| 4,000 ft3| 9.75” x 9.75x 8”| 3.0 lb| 8| 0.52| 0.28
CASPR Pro 1000| 10,000 ft3| 9.75” x 9.75” x 11”| 3.1 lb| 10| 0.64| 0.30
CASPR Pro 2500| 25,000 ft3| 9.75” x 9.75” x 16.75”| 3.3 lb| 18| 1.0| 0.44
CASPR Pro 5000| 50,000 ft3| 10” x 11.3” x 16.75”| 5.0 lb| 36| 2.0| 0.74
Product Contents
Installation Hardware
- (8) #8 3/4 Hex Self-tapping Screws
- (4) Flange Nuts
- (2 or 4) Cell Mounting Screws (2 screws per NCC Cell)
Replacement Parts
The NCC Cell and bulb should be replaced every 18-24 months. Please contact
your distributor for new replacements.
- CASPR Pro 400 NCC Cell Part Number: CELL-HV-5-001-AP
- CASPR Pro 1000 NCC Cell Part Number: CELL-HV-9-001-AP
- CASPR Pro 2500 and 5000 NCC Cell Part Number: CELL-HV-14-001-AP
Recommended Installation Tools
- A – 4” Hole Saw Bit
- B – 3/8” Drill Bit
- C – Drill/Power Driver
- D – Utility Knife
- E – Tin Snips
- F – Phillips Head Screwdriver
Electrical Requirement
All CASPR Pro duct mounted units run on DC 24V. Each unit comes with a power
adapter that will take AC 100-240V. We recommend locating the unit within 6
ft. of a standard 120V Grounded outlet to plug in directly. Long term use on
an extension cord is not recommended due to safety considerations.
If an outlet is not available within 6 feet of the instillation location, you
may hardwire the unit into the HVAC system using a licensed HVAC professional.
Hard-Wiring Requirement
Permanent wiring of the unit into your HVAC system may be completed using a
hardwire assembly (sold separately) and should be done by a licensed HVAC
Installer or Electrical Contractor only.
-
For 110V or 220V Applications:
Black = L1, White = Neutral, Green = Ground -
For International Applications:
Brown = L1, Blue = L2, Green/Yellow = Ground
If DC 24V is available, splice the wire between the brick and the cell housing
to wire directly to the unit circumventing the power brick.
If the voltage is higher than AC 120-240V, you will need a transformer that
converts your supply voltage to DC 24V eliminating the power brick.
When hardwiring any of these units please be mindful of the Maximum Amp draw
that your power supply transformer can handle to prevent damage (Equation:
Power Supply Transformer Amps / CASPR Volts = Maximum Amp Load).
Installation Requirement
-
Unit should be installed downstream of the air handler in the HVAC system.*
**Additional HVAC units may be installed in the Return Plenum for added protection and to keep the internal parts clean. -
The duct work around the installation area should be cleaned and dry to insure proper adhesion of the gasket materials and any tape used.
-
One-two 4” circular openings will need to be cut into the existing duct work to install the unit properly. (2-for CASPR Pro 5000; 1-CASPR Pro 400, 1000, 2500).
Orientation and Airflow
When installing the CASPR Pro 5000, make sure the airflow moves through the
NCC cells as indicated by the blue arrow.
Make sure, when installing several units at once, that they are staggered to
minimize overlap of NCC cells and maximize airflow.
When installing the CASPR Pro 400, 1000, and 2500 make sure the airflow moves
through the NCC cells as indicated by the blue arrow.
Make sure, when installing several units at once, that they are staggered to
minimize overlap of NCC cells and maximize airflow.
Installation Instructions
Diagrams are representative of the CASPR Pro 400, 1000, and 2500. The steps are the same for the CASPR Pro 5000 with slight variations in orientation and number of holes. Please refer to the airflow and orientation section above for proper installation of all models.
- Find a suitable location to mount your Unit.
- If necessary, cut away insulation for your plate to adhere to the duct.
- Using the Adhesive Mounting Bracket,trace the hole location onto the duct. Keep in mind the CASPR Pro 5000 orientation before cutting (Refer to orientation and airflow above).
- Use the Hole Saw and Drill to cut out the marked hole.
Alternative Cutting Method
-
Using the Adhesive Mounting Bracket, trace the hole location onto the duct.
Keep in mind the CASPR Pro 5000 orientation before cutting (Refer to orientation and airflow above). -
Drill holes around the outside edges of the previously marked hole but inside the outer holes of the Adhesive Mounting Bracket.
-
Use the Tin Snips to cut out the space around the marked hole.
-
Remove the plastic backing on your Adhesive Mounting Bracket.
-
Press the Adhesive Mounting Bracket onto the duct. Secure with the (8 Self-Tapping Screws.
-
Remove the packing foam from the NCC Cell
DO NOT TOUCH BULB WITH BARE HANDS -
Connect the Cell to the Ballast Housing using the (2) Cell Mounting Screws provided. Repeat this step if you have a double cell unit.
-
Place the unit and cell through the opening and align the four studs with the four holes in the Ballast Housing.
Secure the unit with the (4) Flange Nuts until it is flush with the duct.
MAKE SURE THE AIRFLOW MOVES THROUGH THE NCC CELL (Refer to orientation and airflow above). -
Plug the Power Cable into the receptacle or have a Licensed Electrician or HVAC Installer hard wire the unit directly into the HVAC system.
Hardwire Instructions
If you plan to Hardwire your CASPR Pro unit directly into the electrical supply you may do so using the hardwire power assembly (sold separately) which accepts AC 120-277V (1.8 A) and outputs DC 24V (2.5 A).
- Place the hardwire assembly at the bottom of the CASPR Unit power supply and attach as demonstrated in the figures below.
- Once the assembly is connected to the unit, fasten the two screws to secure the assembly and the CASPR device together.
- Run an 18-gauge 2-wire cord through the wire outlet (left image below) and to connect the power supply to the transformer (right image below).
Here, red represents AC/L and black represent AC/N. Note that the male connector is already wired into the transformer.
Once the unit is connected to the proper power supply and your unit is running you have successfully connected the hardwired power supply.
Indicator Lights
- Unit Power – Red light is ON.
- Cell Power – Red light is ON.
- Red light ON – Bulbs are on.
- Red light OFF – bulb has burned out and needs to be replaced. Double units have one light for each lamp.
NOTE: THIS MODEL IS NOT WIFI ENABLED;
The Wi-Fi indicator light will not function
Maintenance
Your CASPR Pro unit requires no periodic maintenance beyond normal replacement
of the NCC cells and bulbs every 18-24 months. We recommend the replacement of
the NCC cells and bulbs, even if the bulb appears to be operating normally.
The bulb operation indicator on the face of the unit will glow when the bulb
is in use. If the indicator does not glow and the unit has power, the NCC cell
and bulb should be replaced.
Disposal of the NCC Cell
Please do not throw the used NCC Cells or bulbs in the garbage.
The high intensity bulb used in the CASPR Pro unit contains a very small
amount of mercury. Contact your local Waste Management Center for a proper
disposal procedure.
Changing the NCC Cell
- Remove the Power Cable from the receptacle or ensure the unit isn’t powered.
- Remove the (4) Flange Nuts from the Unit Cover and Remove the Unit Cover and NCC Cell.
- Remove the (2) Screws holding the NCC Cell in place and remove the NCC Cell from the Unit Cover.
- Remove the packing foam from the new NCC Cell
- Exchange the Old NCC Cell with the new NCC Cell and replace the (2) Screws that hold it in place.
- Replace the Cover and NCC Cell in the duct and secure with the (4) Flange Nuts. MAKE SURE THE AIRFLOW MOVES THROUGH THE NCC CELL (Refer to orientation and airflow above).
- Place the Power Cable back into the receptacle or repower your unit.
Warranty Information
NDS Sales LLC d/b/a CASPR Technologies (as “Seller”) offers the following
Express Limited Warranty to a buying customer (a “Buyer”) of a CASPR product
(the “Product”):
Seller warrants to Buyer that (a) the Product will be free from defects caused
by faulty workmanship or materials for three years from date of purchase when
operated under normal conditions and in accordance with Seller’s recommended
use (the “Product Warranty Period),” and that (b) the Components (comprised of
a bulb and a cell) will be free from defects caused by faulty workmanship or
materials for one year from date of purchase when operated under normal
conditions and in accordance with Seller’s recommended use (the “Components
Warranty Period).”
SELLER EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED.
Should Buyer discover a covered defect within the Product Warranty Period or
the Components Warranty Period, Seller will repair or replace (at Seller’s
cost) the Product and/or the Components. Buyer’s sole and exclusive remedy for
Product or Components defects is mlimited to repair or replacement.
To confirm coverage or to schedule repair or replacement under this Express
Limited Warranty, Buyer should contact Seller at
www.casprtech.com/warranty and provide
the serial number located on the Product and proof of purchase. Absence of a
serial number or proof of purchase may void the Express Limited Warranty.
This Express Limited Warranty does not extend to or cover Product damage
caused by accident, fire, flooding, exposure to temperature extremes, abuse,
misuse, improper or unauthorized installation, modification, misapplication,
or repairs performed by persons other than Seller. Repairs performed by
persons other than Seller or Seller’s authorized representative will void the
Express Limited Warranty.
This Express Limited Warranty does not extend to or cover incidental or
consequential damages incurred by Buyer arising from, related to, or in
connection with, any Product or Components defects, including but not limited
to downtime costs, loss of use, loss of revenue, and/or loss of profits.
SALES THROUGH DISTRIBUTOR OR RESELLER
To the extent the Product is purchased by Buyer from an authorized CASPR
distributor or reseller, this Express Limited Warranty passes through to
Buyer.
FOR U.S. APPLICATION ONLY
Product warranties are governed by state and federal laws and may vary from
state to state. This Express Limited Warranty provides Buyer with specific
assurances regarding repair or replacement of the Product. Other warranties
are expressly negated.
FOR CANADIAN APPLICATION ONLY
Canadian, provincial, and territorial sales laws may govern implied
warranties. This Express Limited Warranty provides Buyer with specific
assurances regarding repair or replacement of the Product. Other warranties
are expressly negated. Should there be a difference between this Express
Limited Warranty and Canadian law regarding implied warranties, Canadian law
will control.
Troubleshooting Q&A
How big is the cut hole?
You must cut a 4” diameter hole.
What power does it run on? Voltage
You may use an AC 120VAC With transformer or a DC/AC 24V Direct. Remember that the wire must be cut and spliced in order to properly connect to the device Please see hard wiring requirements.
How do I know that it is working?
The Indicator Lights, on the cell housing, will be on red indicating that the ballast and NCC cell have power and are on. Please see Indicator Lights section above for more information.
What should I do if there is no power to the unit?
Check each connection point to ensure it is properly connected, if this does not work, please contact your distributor.
How often does the bulb need to be changed?
The NCC cells and bulbs need to be replaced once every 18-24 months.
How does it mount? Adhesive or Screws
It mounts using the self-tapping screws NOT the adhesive.