cameo CL200G2 SPOT WHITE 200 W COB-LED Temperature User Manual

June 5, 2024
cameo

cameo CL200G2 SPOT WHITE 200 W COB-LED Temperature User Manual

cameo CL200G2 SPOT WHITE 200 W COB-LED Temperature.jpg

CL 200 G2

YOU‘VE MADE THE RIGHT CHOICE!
We have designed this product to operate reliably over many years. Please read this User‘s Manual carefully, so that you can begin making optimum use of your Cameo Light product quickly. Learn more about Cameo Light on our website WWW.CAMEOLIGHT.COM.

PREVENTIVE MEASURES

  1. Please read these instructions carefully.

  2. Keep all information and instructions in a safe place.

  3. Follow the instructions.

  4. Observe all safety warnings. Never remove safety warnings or other information from the equipment.

  5. Use the equipment only in the intended manner and for the intended purpose.

  6. Use only sufficiently stable and compatible stands and/or mounts (for fixed installations). Make certain that wall mounts are properly installed and
    secured. Make certain that the equipment is installed securely and cannot fall down.

  7. During installation, observe the applicable safety regulations for your country.

  8. Never install and operate the equipment near radiators, heat registers, ovens or other sources of heat. Make certain that the equipment is always
    installed so that is cooled sufficiently and cannot overheat.

  9. Never place sources of ignition, e.g., burning candles, on the equipment.

  10. Ventilation slits must not be blocked.

  11. Keep a minimum distance of 20 cm around and above the device.

  12. Do not use this equipment in the immediate vicinity of water (does not apply to special outdoor equipment – in this case, observe the special instructions noted below. Do not expose this equipment to flammable materials, fluids or gases. Avoid direct sunlight!

  13. Make certain that dripping or splashed water cannot enter the equipment. Do not place containers filled with liquids, such as vases or drinking vessels, on the equipment.

  14. Make certain that objects cannot fall into the device.

  15. Use this equipment only with the accessories recommended and intended by the manufacturer.

  16. Do not open or modify this equipment.

  17. After connecting the equipment, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.

  18. During transport, make certain that the equipment cannot fall down and possibly cause property damage and personal injuries.

  19. If your equipment is no longer functioning properly, if fluids or objects have gotten inside the equipment or if it has been damaged in another way, switch it off immediately and unplug it from the mains outlet (if it is a powered device). This equipment may only be repaired by authorized, qualified personnel.

  20. Clean the equipment using a dry cloth.

  21. Comply with all applicable disposal laws in your country. During disposal of packaging, please separate plastic and paper/cardboard.

  22. Plastic bags must be kept out of reach of children.

  23. Please note that changes or modifications not expressly approved by the party responsible for compliance could void the user´s authority to operate the equipment.
    FOR EQUIPMENT THAT CONNECTS TO THE POWER MAINS:

  24. CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connected to an outlet with a protective
    ground. Never deactivate the protective ground of a power cord.

  25. If the equipment has been exposed to strong fluctuations in temperature (for example, after transport), do not switch it on immediately. Moisture and condensation could damage the equipment. Do not switch on the equipment until it has reached room temperature.

  26. Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician.

  27. Do not step on the power cord. Make certain that the power cable does not become kinked, especially at the mains outlet and/or power adapter and the equipment connector.

  28. When connecting the equipment, make certain that the power cord or power adapter is always freely accessible. Always disconnect the equipment from the power supply if the equipment is not in use or if you want to clean the equipment. Always unplug the power cord and power adapter from the power outlet at the plug or adapter and not by pulling on the cord. Never touch the power cord and power adapter with wet hands.

  29. Whenever possible, avoid switching the equipment on and off in quick succession because otherwise this can shorten the useful life of the equipment.

  30. IMPORTANT INFORMATION: Replace fuses only with fuses of the same type and rating. If a fuse blows repeatedly, please contact an authorised service centre.

  31. To disconnect the equipment from the power mains completely, unplug the power cord or power adapter from the power outlet.

  32. If your device is equipped with a Volex power connector, the mating Volex equipment connector must be unlocked before it can be removed. However, this also means that the equipment can slide and fall down if the power cable is pulled, which can lead to personal injuries and/or other damage. For this reason, always be careful when laying cables.

  33. Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.

  34. The device must only be installed in a voltage-free condition (disconnect the mains plug from the mains).

  35. Dust and other debris inside the unit may cause damage. The unit should be regularly serviced or cleaned (no guarantee) depending on ambient conditions (dust etc., nicotine, fog) by qualified personnel to prevent overheating and malfunction.

  36. Please keep a distance of at least 0.5 m to any combustible materials.

  37. Power cables to power multiple devices must have a cross-section of at least 1.5 mm². Within the EU, the cables must correspond to H05VV-F, or similar. Suitable cables are offered by Adam Hall. With these cables, you can connect multiple devices via the power OUT connection to the power IN connection of an additional device. Make sure that the total current consumption of all connected devices does not exceed the specified value on all connected devices (label on the device). Make sure to keep power cable connections as short as possible.

Caution - Risk of Electric Shock CAUTION:
To reduce the risk of electric shock, do not remove cover (or back). There are no user serviceable parts inside. Maintenance and repairs should be exclusively carried out by qualified service personnel.

FIG 3 Symbols.JPG

CAUTION! HIGH VOLUMES IN AUDIO PRODUCTS!
This device is meant for professional use. Therefore, commercial use of this equipment is subject to the respectively applicable national accident prevention rules and regulations. As a manufacturer, Adam Hall is obligated to notify you formally about the existence of potential
health risks.

Hearing damage due to high volume and prolonged exposure: When in use, this product is capable of producing high sound-pressure levels (SPL) that can lead to irreversible hearing damage in performers, employees, and audience members. For this reason, avoid prolonged
exposure to volumes in excess of 90 dB.

INTRODUCTION

LED SPOTLIGHT
CLCL200G2

CONTROL FUNCTIONS:
1-channel, 2-channel 1, 2-channel 2, 3-channel, 4-channel DMX control
Master/slave mode
Standalone functions

FEATURES:
DMX-512 control. 200 W high-intensity cold white/warm white COB LED. Stroboscope. 4 dimmer curves. Color temperature settings from 7800 K to 3200 K. 3-pin DMX connections. Stand or mounting bracket. Flap included. Operating voltage 100–240 V AC. Power consumption 200 W.

CONNECTIONS, OPERATING AND DISPLAY ELEMENTS

FIG 4 CONNECTIONS, OPERATING AND DISPLAY ELEMENTS.JPG

  1. POWER IN
    Blue power input socket for power supply to the device. A suitable power cable is included.

  2. POWER OUT
    White power output socket for the power supply of additional CAMEO spotlights. Ensure that the total current consumption of all connected devices does not exceed the value specified on the device in amperes (A).

  3. FUSE
    Fuse holder. Fuse F3AL/250 V (5 x 20 mm). IMPORTANT: Replace the fuse only with a fuse of the same type and value. In the event of repeated fuse failure, please contact an authorised service centre.

  4. DMX IN
    Male 3-pin XLR socket for connection to a DMX control device (e.g. DMX console).

  5. DMX OUT
    Female 3-pin XLR socket for sending the DMX control signal.

  6. LC DISPLAY
    The illuminated LC display shows the operating mode and other system information.

  7. OPERATING KEYS
    MODE – press MODE to access the selection menu for system settings. Press repeatedly to return to the main display. ENTER – press ENTER to access the menu levels so as to be able to change settings and access the sub-menus. Confirm changed settings by pressing ENTER. UP and DOWN – select individual menu items in the selection menu (DMX address, operating mode etc.) and in the sub-menus. Allow changes to be made to a menu item setting such as the DMX address as required.

  8. EYELET FOR SECURING CABLE
    Overhead installation may only be carried out by qualified personnel. A suitable safety cable must be fitted to the spotlight’s securing lug to ensure that it does not fall down.

OPERATION

As soon as the spotlight is correctly connected to the power supply, the following will be displayed in succession: “Welcome to Cameo”, the model name and the software version. After this process, the spotlight is ready for operation and starts in the previously selected mode. If the
DMX operating mode is activated and there is no DMX signal at the DMX input, the display will start to flash after a few seconds. After approximately 1 minute of inactivity, the display will automatically show the currently active operating mode.

SET DMX START ADDRESS (DMX Addr)
Press the MODE button repeatedly until “Menu” appears in the top line of the display. If necessary, select the menu item “Menu DMX Addr” using UP and DOWN and press ENTER. Now select the desired DMX start address using UP and DOWN, and press ENTER to confirm.

FIG 5  SET DMX START ADDRESS.JPG

SET OPERATING MODE (Mode)
Press the MODE button repeatedly until “Menu” appears in the top line of the display. If necessary, select the menu item “Menu Mode” using UP and DOWN and then press ENTER. Now select the desired operating mode using UP and DOWN and confirm with ENTER (see tables, note sub-menus). The comprehensive DMX tables can be found in these instructions under “DMX CONTROL”.

FIG 6 Operating Modes.JPG

FIG 7 Operating Modes.JPG

SYSTEM SETTINGS (settings)

To access system settings, press the MODE button repeatedly until “Menu” appears in the top line of the display. Now select the menu item “Menu Settings” using UP and DOWN and press ENTER. Select the desired sub-menu item using UP and DOWN once again, and confirm with
ENTER (see tables, note sub-menus). Now change the settings as required using UP and DOWN and confirm the changes with ENTER.

FIG 8 Operating Modes.JPG

FIG 9 Operating Modes.JPG

Dimmer curves

FIG 10 Dimmer curves.JPG

SYSTEM INFORMATION (System)

In order to view system information, press the MODE button repeatedly until “Menu” appears in the top line of the display. If necessary, select the menu item “Menu System” using UP and DOWN and press ENTER. Use UP and DOWN to select the desired sub-menu item, and press ENTER to display the relevant information.

FIG 11 SYSTEM INFORMATION.JPG

RESET
To restore the spotlight’s factory settings, keep the MODE button pressed down for approx. 5 seconds.

SET-UP AND INSTALLATION

The integrated double bracket allows the lamp to be positioned in a suitable location on a level surface. Installation on a traverse is possible using a suitable traverse clamp (not supplied). Ensure firm connection to the mounting bracket and secure the spotlight to the securing lug (A)
with a suitable safety cable.

Important: Overhead installation may only be carried out by qualified personnel.

FIG 12 SET-UP AND INSTALLATION.jpg

FLAP

In order to mount the flap included, remove the four screws from the lens attachment frame (see arrows in the figure below), place the flap on the frame and screw it into place using the screws previously removed. The flap can also be attached on the spotlight at a 90° rotation.

FIG 13 FLAP.jpg

DMX TECHNOLOGY

DMX-512

DMX (Digital Multiplex) is the designation for a universal transmission protocol for communications between corresponding devices and controllers. A DMX controller sends
DMX data to the connected DMX device(s). The DMX data is always transmitted as a serial
data stream that is forwarded from one connected device to the next via the “DMX IN” and
“DMX OUT” connectors (XLR plug-type connectors) that are found on every DMX- capable
device, provided the maximum number of devices does not exceed 32 units. The last device
in the chain needs to be equipped with a terminator (terminating resistor).

DMX CONNECTION
DMX is the common “language” via which a very wide range of types and models of equipment from various manufacturers can be connected with one another and controlled via a central controller, provided that all of the devices and the controller are DMX compatible. For optimum data transmission, it is necessary to keep the connecting cables between the individual devices as short as possible. The order in which the devices are integrated in the DMX network has no influence on the addresses. Thus the device with the DMX address 1 can be located at any position in the (serial) DMX chain: at the beginning, at the end or somewhere in the middle.
If the DMX address 1 is assigned to a device, the controller “knows” that it should send all data allocated to address 1 to this device regardless of its position in the DMX network.

SERIAL CONNECTION OF MULTIPLE LIGHTS

  1. Connect the male XLR connector (3-pin or 5-pin) of the DMX cable to the DMX output (female XLR socket) of the first DMX device
    (e.g. DMX-Controller).

  2. Connect the female 3-pin XLR connector of the DMX cable connected to the first projector to the DMX input (male 3-pin socket) of the next DMX device. In the same way, connect the DMX output of this device to the DMX input of the next device and repeat until all devices have been connected. Please note that as a rule, DMX devices are connected in series and connections cannot be shared without active splitters. The maximum number of DMX devices in a DMX chain should not exceed 32 units.

The Adam Hall 3 STAR, 4 STAR, and 5 STAR product ranges include an extensive selection of suitable cables.

DMX CABLES
When fabricating your own cables, always observe the illustrations on this page. Never connect the shielding of the cable to the ground contact of the plug, and always make certain that the shielding does not come into contact with the housing of the XLR plug. If the shielding
is connected to the ground, this can lead to short-circuiting and system malfunctions.

Pin Assignment

DMX cable with 3-pin XLR connectors:

FIG 15 Pin Assignment.JPG

DMX cable with 5-pin XLR connectors (pin 4 and 5 are not used):

DMX TERMINATORS (TERMINATING RESISTORS)
To prevent system errors, the last device in a DMX chain needs to be equipped with a terminating resistor (120 ohm, 1/4 Watt).
3-pin XLR connector with a terminating resistor: K3DMXT3
5-pin XLR connector with a terminating resistor: K3DMXT5

FIG 17 Pin Assignment.JPG

DMX ADAPTER
The combination of DMX devices with 3-pin connectors and DMX devices with 5-pin connectors in a DMX chain is possible with suitable adapters.

FIG 18 Pin Assignment.JPG

TECHNICAL DATA

FIG 19 TECHNICAL DATA

FIG 20 TECHNICAL DATA.JPG

FIG 21 TECHNICAL DATA.JPG

MANUFACTURER´S DECLARATIONS

MANUFACTURER‘S WARRANTY & LIMITATIONS OF LIABILITY
You can find our current warranty conditions and limitations of liability at: https://cdn-shop.adamhall.com/media/pdf/Manufacturers-Declarations- CAMEO_DE_EN_ES_FR.pdf. To request warranty service for a product, please contact Adam Hall GmbH, Adam-Hall-Str. 1,
61267 Neu Anspach / Email: Info@adamhall.com / +49 (0)6081 / 9419-0.

CORRECT DISPOSAL OF THIS PRODUCT
(valid in the European Union and other European countries with a differentiated waste collection system) This symbol on the product, or on its documents indicates that the device may not be treated as household waste. This is to avoid environmental damage or personal injury due to uncontrolled waste disposal. Please dispose of this product separately from other waste and have it recycled to promote sustainable economic activity. Household users should contact either the retailer where they purchased this product, or their local government office, for details on where and how they can recycle this item in an environmentally friendly manner. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial waste for disposal.

CE Compliance
Adam Hall GmbH states that this product meets the following guidelines (where applicable):
R&TTE (1999/5/EC) or RED (2014/53/EU) from June 2017
Low voltage directive (2014/35/EU)
EMV directive (2014/30/EU)
RoHS (2011/65/EU)
The complete declaration of conformity can be found at www.adamhall.com.
Furthermore, you may also direct your enquiry to info@adamhall.com.

DMX CONTROL

FIG 22 DMX CONTROL.JPG

FIG 23 DMX CONTROL.JPG

CAMEOLIGHT.COM

Adam Hall GmbH | Adam-Hall-Str. 1 | 61267 Neu-Anspach | Germany
Tel. +49(0)6081/9419-0 | Fax +49(0)6081/9419-1000