MOEN F9810 Standard Carbon Replacement Filtration System Installation Guide

May 15, 2024
Moen

INS12268C – 07/23
INSTALLATION GUIDE
F9810 and F9820 Filtration System

F9810 Standard Carbon Replacement Filtration System

Image is for reference only (Style varies by model)
Record Purchased Model Number: (Save instruction sheet for future reference)
Register Online: www.moen.com/product-registration

PLEASE CONTACT MOEN FIRST
For Installation Help, Missing or Replacement Parts (USA) 1-800-BUY-MOEN (1-800-289-6636) www.moen.com
(Canada) 1-800-465-6130 www.moen.ca
(Costa Este) 011 52 800-718-4345 www.moen.com.mx

HELPFUL TOOLS
For safety and ease of faucet replacement, Moen recommends the use of these helpful tools.

Required for Optional Hardwire Installation

Parts List

MOEN F9810 Standard Carbon Replacement Filtration System - Parts
List

A. Manifold Cap
B. Manifold
C. Filter Housing Tool
D. Filter
E. Protective Cap| F. Housing Cap
G. Housing Waterway
H. Filter Housing
I. Filter Life Label Sheet
J. 2 AAA Batteries
---|---

Do not install filtration unit in applications where failure or leakage would cause damage.
System to be supplied only with cold water.
Do not install in area where solvents or sprays can reach filter. Crazing and failure may result.
Do not install outdoors in direct sunlight.
If system experiances pressure surges, install a pressure regulator before the filter to keep pressure below 80 psi maximum.
Because of filter housing’s limited life and to prevent costly repairs or possible water damage from leaks or flooding, the housing MUST be replaced every three years from date of install.

System installation must comply with all state and local laws, regulations and plumbing codes.

Turn off cold water supply.

Activate filtered water flow (method will vary based on faucet style). Allow sufficient time for faucet to drain any remaining water.

1. Rotate the installed Filter Housing Unit (H) to ensure the unlocked mark aligns with the manifold (B).
2. Remove Sump Assembly from the Mounting Manifold by gently dislodging the product.

Remove Filter Housing (H) from Housing Cap (F) by using the Filter Housing Tool (C).

Remove Housing waterway (G) and Filter (D) from Filter housing (H).
Discard and throw away old filter unit.

Unwrap new Filter (D) and install with Housing Waterway (G) into Filter Housing (H).

1. Lower Housing Cap (F) onto Housing Waterway (G).
2. Screw Housing Cap (F) onto Filter Housing (H). If Housing Cap gets stuck during rotation, pull up on Housing Waterway and continue to rotate cap.

Tighten Housing Cap (F) to Filter Housing (H) with Filter Housing Tool (C).

1. Install Sump Assembly into Mounting Manifold by inserting the product up and turning 1/4 to secure.
2. Ensure locked icon on the filter housing aligns with the mark on the manifold.

Remove Manifold Cap (A) from Manifold (B) by gently unscrewing the cap.

Remove battery box cover and remove existing 2 AAA batteries from the Manifold Cap (A).

1. For F9810 model, ensure that the timer duration switch is set to “6 months”. For F9820 ensure that the timer duration switch is set to “12 months”.
2. Install 2 AAA batteries (J) into the Manifold Cap (A).
3. Slide battery box cover into place.

After batteries are installed, attached LEDs will blink for 20 seconds to show that the batteries were properly installed. If it does not flash, remove batteries and reinstall as shown in Step 11.

Install Manifold Cap (A) into Manifold (B) by placing Cap on top of Manifold and gently turning until secure.

Turn on cold water supply. Let water run for 10 minutes for flushing of any debris.

Installation complete. Image may vary based on your faucet style.

Performance Data Sheet: F9800 with F9820 Advanced Filter and F9810 Basic Filter

Flow Rate: 1.6 gpm (6.06 Lpm)
Capacity: F9820: 845 gal (3,199 L) F9810: 500 gal (1,893 L)
Temperature : 35-100°F (2-38°C)
Pressure: 30-80 psi (207-552 kPA)
Filtration Function : Chemical-Mechanical

This system has been tested according to NSF/ANSI 42, 53, and 401 for the reduction of substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42, 53, and 401.
NOTE: While the testing was performed under standard laboratory conditions, actual performance may vary. Contaminant reduction testing is conducted at regular intervals by certifying agency to maintain certification. Not all water will contain contaminants listed. Compounds certified under NSF/ANSI 401 have been deemed as incidental contaminants / emerging compounds. Incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. Filter is only to be used with cold water. System and installation must comply with all state and local laws and regulation. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Please refer to Installation Guide for general operation, maintenance requirements, and the manufacturer’s warranty. It is essential that the manufacturer’s recommended installation, maintenance, and filter replacement requirements be carried out for the product to perform as advertised. If this device is not maintained and operated as specified, there is a risk of exposure to contaminants.
Please visit www.moen.com to view the full Performance Data Sheet.

F9800 with F9820 Advanced filter and F9800 with F9810 Basic filter is certified by IAPMO R&T against NSF/ANSI 42, 53 and 401 for the claims enumerated on the Performance Data Sheet and at www.IAPMO.org, to NSF/ANSI 372 for Low Lead Content and CSA B483.1.

Performance Data Sheet: F9800 with F9820 Advanced Filter and F9810 Basic Filter

Substance| Influent Challenge Concentration| Min. Allowable % Reduction OR Max. Allowable Product Water Concentration
---|---|---
NSF/ANSI 42
Chlorine| 2.0 mg| ≥50% reduction
Particulates (0.5 to <1um) – Class 1| at least 10,000 particulates/ml| ≥85% reduction
NSF/ANSI 53
Asbestos (fibers/L)| 10^7 – 10^8 fibers/L| >99% reduction
Chloroform (VOC surrogate chemical)| 0.300 mg/L +/- 10%| 0.015 mg/L
Cysts (applicable for F9820 only)| at least 50,000/L| >99.95% reduction
Lead  (pH 6.5)| 0.15 mg/L +/- 10%| 0.005 mg/L
Lead   (pH 8.5)| 0.15 mg/L +/- 10%| 0.005 mg/L
MTBE  (applicable for F9820 only)| 0.015 mg/L +/- 20%| 0.005 mg/L
Mercury (pH 6.5)| 0.006 mg/L +/- 10%| 0.002 mg/L
Mercury  (pH 8.5)| 0.006 mg/L +/- 10%| 0.002 mg/L
PFOA/PFOS (applicable for F9820 only)| 0.0015 mg/L +/- 20%| 0.00007 mg/L
Turbidity| 11 +/- 1 NTU| 0.5 NTU
NSF/ANSI 401
Antenolol| 200 ng/L +/- 40%| 30 ng/L
Bisphenol A| 2,000 ng/L +/- 40%| 300 ng/L
Carbamazepine| 1,400 ng/L +/- 40%| 200 ng/L
DEET| 1,400 ng/L +/- 40%| 200 ng/L
Estrone| 140 ng/L +/- 40%| 20 ng/L
Ibuprofen| 400 ng/L +/- 40%| 60 ng/L
Linuron| 140 ng/L +/- 20%| 20 ng/L
Mepromabate| 400 ng/L +/- 40%| 60 ng/L
Metolachlor| 1,400 ng/L +/- 40%| 200 ng/L
Naproxen| 140 ng/L +/- 40%| 20 ng/L
Nonylphenol| 1,400 ng/L +/- 40%| 200 ng/L
Phenytoin| 200 ng/L +/- 40%| 30 ng/L
TCPP| 5,000 ng/L +/- 20%| 700 ng/L
TCPP| 5,000 ng/L +/- 20%| 700 ng/L
Trimethoprim| 140 ng/L +/- 40%| 20 ng/L

Organic Chemicals Included by Surrogate Testing

Chemical| Drinking Water Regulatory Level (MCL/MAC) (mg/L)| Influent Challenge Concentration(mg/L)| Chemical Reduction Percent| Max. Allowable Product
Water Concentration (mg/L)
---|---|---|---|---
Alachlor| 0.002| 0.05| > 98| 0.001 3
Atrazine| 0.003| 0.1| > 97| 0.003 3
Benzene| 0.005| 0.081| > 99| 0.001 3
Carbofuran| 0.04| 0.19| > 99| 0.001 3
Carbon Tetrachloride| 0.005| 0.078| 98| 0.0018 4
Chlorobenzene| 0.1| 0.077| > 99| 0.001 3
Chloropicrin| –| 0.015| 99| 0.0002 3
2,4-D| 0.07| 0.11| 98| 0.0017 4
Dibromo chloropropane (DBCP)| 0.0002| 0.052| > 99| 0.00002 3
O-Dichlorobenzene| 0.6| 0.08| > 99| 0.001 3
P-Dichlorobenzene| 0.075| 0.04| > 98| 0.001 3
1,2-Dichloroethane| 0.005| 0.088| 95 5| 0.0048 5
1,1-Dichloroethylene| 0.007| 0.083| > 99| 0.001 3
cis-1,2-Dichloroethylene| 0.07| 0.17| > 99| 0.0005 3
trans-1,2-Dichloroethylene| 0.1| 0.086| > 99| 0.001 3
1,2-Dichloropropane| 0.005| 0.08| > 99| 0.001 3
cis-1,3-Dichloropropylene| –| 0.079| > 99| 0.001 3
Dinoseb| 0.007| 0.17| 99| 0.0002 4
Endrin| 0.002| 0.053| 99| 0.00059 4
Ethylbenzene| 0.7| 0.088| > 99| 0.001 3
Ethylene Dibromide (EDB)| 0.00005| 0.044| > 99| 0.00002 3
Haloacetonitriles (HAN)| –


–| 0.022
0.024
0.0096
0.015| 98
98
98
98| 0.0005 3
0.0006 3
0.0002 3
0.0003 3
Haloketones (HK)
1,1-Dichloro-2-Propanone
1,1,1-Trichloro-2-Propanone| –
–| 0.0072
0.0082| 99
96| 0.0001 3
0.0003 3
Chemical| Drinking Water Regulatory Level
(MCL/MAC) (mg/L)| Influent Challenge Concentration(mg/L)| Chemical Reduction Percent| Max. Allowable Product
Water Concentration (mg/L)
---|---|---|---|---
Heptachlor (H-34, Heptox)| 0.0004| 0.025| > 99| 0.00001
Heptachlor Epoxide| 0.0002| 0.0107 6| 98| 0.0002 6
Hexachlorobutadiene| –| 0.044| > 98| 0.001 3
Hexachlorocyclopentadiene| 0.05| 0.06| > 99| 0.000002 3
Lindane| 0.0002| 0.055| > 99| 0.00001 3
Methoxychlor| 0.04| 0.05| > 99| 0.0001 3
Pentachlorophenol| 0.001| 0.096| > 99| 0.001 3
Simazine| 0.004| 0.12| > 97| 0.004 3
Styrene| 0.1| 0.15| > 99| 0.0005 3
1,1,2,2-Tetrachloroethane| –| 0.081| > 99| 0.001 3
Tetrachloroethylene| 0.005| 0.081| > 99| 0.001 3
Toluene| 1| 0.078| > 99| 0.001 3
2,4,5-TP (Silvex)| 0.05| 0.27| 99| 0.0016 4
Tribromoacetic Acid| –| 0.042| > 98| 0.001 3
1,2,4-Trichlorobenzene| 0.07| 0.16| > 99| 0.0005 3
1,1,1-Trichloroethane| 0.2| 0.084| 95| 0.0046 4
1,1,2-Trichloroethane| 0.005| 0.15| > 99| 0.0005 3
Trichloroethylene| 0.005| 0.18| > 99| 0.0010 3
Trihalomethanes (includes):| 0.08| 0.3| 95| 0.015
Xylenes (Total)| 10| 0.07| > 99| 0.001 3

  1. These harmonized values were agreed upon by representatives of US EPA and Health Canada for the purpose of evaluating products to the requirements of this Standard.
  2. Influent challenge levels are average influent concentrations determined in surrogate qualification testing.
  3. Maximum product water level was not observed but was set at the detection limit of analysis.
  4. Maximum product water level is set at a value determined in surrogate qualification testing.
  5. Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing.
  6. The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. This data was used to calculate an upper occurrence concentration that would produce a maximum product water level at the MCL.

For Purchases Made in Iowa: This form must be signed and dated by the buyer and seller prior to the consummation of this sale. This form should be retained on file by the seller for a minimum of 2 years.

Buyer Name………………….
Date…………………………….

Seller Name………………….
Date…………………………….

Moen Limited Lifetime Warranty

Moen products have been manufactured under the highest standards of quality and workmanship. Moen warrants to the original consumer purchaser for as long as the original consumer purchaser owns their home (the “Warranty Period” for homeowners), that this product will be leak- and drip-free during normal use and all parts and finishes of this product will be free from defects in material and manufacturing workmanship. All other purchasers (including purchasers for industrial, commercial and business use) are
warranted for a period of 5 years from the original date of purchase (the “Warranty Period” for non-homeowners).
If this product should ever develop a leak or drip during the Warranty Period, Moen will FREE OF CHARGE provide the parts necessary to put the product back in good working condition and will replace FREE OF CHARGE any part or finish that proves defective in material and manufacturing workmanship, under normal installation, use and service. Replacement parts may be obtained by calling 1-800-289-6636 (Canada 1-800-465-6130), or by writing to the address shown. Proof of purchase (original sales receipt) from the original consumer purchaser must accompany all warranty claims. Defects or damage caused by the use of other than genuine Moen parts is not covered by this warranty. This warranty is applicable only to products purchased after December, 1995 and shall be effective from the date of purchase as shown on purchaser’s receipt.
This warranty is extensive in that it covers replacement of all defective parts and finishes. However, damage due to installation error, product abuse, product misuse, or use of cleaners containing abrasives, alcohol or other organic solvents, whether performed by a contractor, service company, or yourself, are excluded from this warranty.
Moen will not be responsible for labor charges and/ or damage incurred in installation, repair or replacement, nor for any indirect, incidental or consequential damages, losses, injury or costs of any nature relating to this product. Except as provided by law, this warranty is in lieu of and excludes all other warranties, conditions and guarantees, whether expressed or implied, statutory or otherwise, including without restriction those of merchantability or of fitness for use.
Some states, provinces and nations do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state, province to province, nation to nation. Moen will advise you of the procedure to follow in making warranty claims. Simply write to Moen Incorporated using the address below. Explain the defect and include proof of purchase and your name, address, area code and telephone number.

Moen Incorporated
25300 Al Moen Drive
North Olmsted, Ohio 44070-8022
U.S.A.

INS12268C – 07/23

07/12/2023 INS12268C 500000577870
Released (10

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Moen User Manuals