iPOWER GXS5000D Dual Fuel Portable Generator
Product Information
Specifications
- Model: GXS5000D
- Model No.: 2232008
- Fuel Type: Gasoline, Propane/LPG
- Oil Type: Engine oil (specified)
- Starting Method: Dial switch knob
- Power Output: Check operator’s manual
Product Usage Instructions
Wheel Kit Installation
Follow these steps to install the wheel kit:
- Slide the axle pin through the wheel, flat washer, and mount point on the frame.
- Secure with cotter pin and assemble Cap to Wheel.
- Attach the support leg to the generator frame using the provided bolts and nuts.
Fuel and Oil
Ensure proper fuel and oil levels:
- Use clean, fresh regular unleaded gasoline with a minimum of 87 octane.
- Pour engine oil into the engine using a funnel and fill to the upper mark of the oil dipstick.
Safety Precautions
Before starting the generator:
- Adjust the shock-absorbing seat for proper clearance.
- Avoid indoor use to prevent carbon monoxide poisoning.
- Remove support brackets before operation to prevent damage.
Starting the Generator
To start the generator:
- Turn the starting dial switch knob to the ON position.
- Plug in items to be powered using grounded extension cords.
FAQ
-
Q: What fuel type should I use?
A: Use clean, fresh regular unleaded gasoline with a minimum of 87 octane. -
Q: Can I use the generator indoors?
A: No, using the generator indoors can result in carbon monoxide poisoning. Only operate it outdoors and far away from windows, doors, and vents. -
Q: How do I start the generator?
A: Turn the starting dial switch knob to the ON position and plug in items to be powered using grounded extension cords.
Generator Quick Start Guide
Unpack Generator: Remove generator, accessories, inserts and Literature
from carton. If any item is missing or damaged, contact our product service
department at 855-888-3598.
Included Items
WARNING
This Quick Reference Guide is not substitute for reading the operator’s
manual. To reduce the risk of injury or death, user must read and understand
the operator’s manual before using this product. All pages references to the
operator’s manual.
Operation
- Install the wheel kit
- Slide the axle pin(B) through the wheel(C), flat washer(D) and mount point on the frame(E). Secure them with cotter pin(F),then assemble Cap(A) to Wheel(C).
- Attach the support leg(H) to the generator frame with flange bolt(G)(M8X16) and flange lock nut(I)(M8).
- Add Lubricant and Fuel
- Use a funnel to pour provided engine oil into engine. Fill to the upper mark of the oil dipstick H.
- Use clean / fresh regular UNLEADED gasoline with a minimum 87 octane.
- Use Propane/LPG hose with regulator to connect propane/LPG tank and generator.
- Adjust Shock-absorbing Seat
- Before operating the generator, the shock-absorbing seat (cushion) must be adjusted for proper clearance. Loosen the lock nut and adjust the shock-absorbing seat so there is a 3mm gap between the top of the M seat and the bottom of the motor bracket. Re-tighten the lock nut.
- Removal of Shipping Support Brackets
- Remove the bolt (E) with double open wrench (8mm-10mm) (B).
- Remove the bolt (F) and nut (C) with double open wrench (13mm-15mm) (A) and double open wrench (8mm-10mm) (B). CAUTION Failure to remove the support brackets, can result in damage to your generator, possible personal injury and avoid your warranty.
- Start Generator
Move generator outside to a flat, level surface, away from doors, windows and vents.
Danger
- Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
- NEVER use inside a home or garage, EVEN IF doors and windows are open.
- Only use OUTSIDE and far away from windows, doors and vents.
- Avoid other generator hazards. READ MANUAL BEFORE USE.
WARNING Do not overload generator or electrical cords. Consult operation manual.
Select the Fuel Source (Gasoline)
- Make certain the propane tank is fully closed.
- Add gasoline to the fuel tank.
- Turn the starting dial switch to the position.
- Start / Empezar / Commencer
- Move the choke lever to the “START” position.
- Pull recoil starter slowly until resistance is felt, then pull rapidly.
- Move the choke lever to the “RUN” position.
- Plug in items to be powered, using only grounded extension cords.
Select the Fuel Source (Propane/LPG)
-
Connect the LPG gas hose to the propane fuel source.
-
Fully open the Propane/LPG cylinder knob.
-
Turn the starting dial switch knob to the position.
-
Start / Empezar / Commencer
- Move the choke lever to the “START” position.
- Pull recoil starter slowly until resistance is felt, then pull rapidly.
- Move the choke lever to the “RUN” position.
-
Plug in items to be powered, using only grounded extension cords.
Shutdown and Storage
- Remove any load from the generator.
- Turn the fuel switch to the “OFF” position.
- Turn the fuel valve knob to the OFF position
Changing Fuels
- Disconnect all electrical loads from the generator.
- Stop the engine (generator).
- Gasoline to propane/LPG
- Propane/LPG to Gasoline
- Fully open the Propane/LPG cylinder knob.
- Turn the starting dial switch knob to the position.
- Make certain the propane tank is fully closed.
- Turn the starting dial switch to the position.
- Start the engine (generator).
If generator is to be stored for longer than 30 days, refer to The operator’s manual for further Instruction.