Product Information

  • The XOS2300iD is a portable generator designed for outdoor use to provide power for various devices and appliances.
  • It features a recoil starter for easy ignition and can run on gasoline or propane/LPG fuel sources.
  • The generator is equipped with safety features to protect users from hazards, including carbon monoxide poisoning.

Product Usage Instructions

Preparing the Generator

  • Fill the oil dipstick to the upper mark.
  • Make sure the maintenance cover is in place.
  • Ensure the propane tank is fully closed.

Fueling the Generator

  • Add gasoline to the fuel tank.
  • Turn the fuel cap vent lever to the ON position if using gasoline.
  • Connect the LPG gas hose to the propane fuel source if using propane/LPG.

Starting the Generator

  • Plug-in items are to be powered using grounded extension cords.
  • Turn the starting dial switch to the ON position.
  • Pull the recoil starter slowly until resistance is felt, then pull rapidly.

Stopping the Generator:

  • Turn the starting dial switch to the engine stop position when the engine needs to be stopped.

Changing Fuels:

  • To switch from gasoline to propane/LPG, follow the provided instructions in the manual.

FAQ

Q: Can I use the generator indoors?

A: No, using the generator indoors can be fatal due to carbon monoxide emissions. Always operate the generator outdoors in a well-ventilated area.

Q: What should I do if I encounter difficulties starting the generator?

A: Refer to the operator’s manual for troubleshooting tips. If issues persist, contact customer support at 855-888-3598 or email support@a-ipower.com.

  • Unpack Generator: Remove the generator, accessories, inserts, and Literature from the carton.
  • If any item is missing or damaged, contact our product service department at 855-888-3598.

Included Items

A-iPower-801004-Inverter-Dual-Fuel-Generator-FIG-1

  • WARNING This Quick Reference Guide is not a substitute for reading the operator’s manual.
  • To reduce the risk of injury or death, the user must read and understand the operator’s manual before using this product. All pages reference to the operator’s manual.

Add Lubricant and Fuel

  • Loosen the maintenance cover knobs to remove the cover.
  • Use a funnel to pour 10W-30 engine oil into the engine.
  • Fill to the upper mark of the oil dipstick H.A-iPower-801004-Inverter-Dual-Fuel-Generator-FIG-2
  • Use clean/fresh regular UNLEADED gasoline with a minimum of 87 octane.
  • Use a Propane/LPG hose with the regulator to connect the propane/LPG tank and generator.

Start Generator

Move the generator outside to a flat, level surface, away from doors, windows, and vents.

Danger

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.A-iPower-801004
-Inverter-Dual-Fuel-Generator-FIG-3

  • NEVER use inside a home or garage, EVEN IF doors and windows are open.
  • Only use OUTSIDE and far away from windows, doors, and vents.
  • Avoid other generator hazards. READ THE MANUAL BEFORE USE.
  • WARNING Do not overload the generator or electrical cords. Consult the operation manual.

Select the Fuel Source (Gasoline)

  1. Add gasoline to the fuel tank.
  2. Turn the fuel cap vent lever to the “ON” position.
  3. Make certain the propane tank is fully closed.
  4. Turn the starting dial switch to the ON position.A-iPower-801004-Inverter-Dual-Fuel-Generator-FIG-5
  5. Pull the recoil starter slowly until resistance is felt, then pull rapidly.
  6. Turn the starting dial switch to the RUN position.
  7. Plug in items to be powered, using only grounded extension cords.

Note: For restarting a warm engine, turn the starting dial switch directly to the “RUN” position.

Select the Fuel Source (Propane/LPG)

  1. Connect the LPG gas hose to the propane fuel source.
  2. Fully open the Propane/LPG cylinder knob
  3. Turn the starting dial switch to the ON position.
    • Note: For restarting a warm engine, turn the starting dial switch directly to the “RUN position.
  4. Pull the recoil starter twice.
  5. Turn the starting dial switch to the RUN position.
  6. Pull the recoil starter slowly until resistance is felt, then pull rapidly.
  7. Plug in items to be powered, using only grounded extension cords.A-iPower-801004-Inverter-Dual-Fuel-Generator-FIG-11

For Cold Weather Starting

  • While you must run your generator outside, you may keep the generator in a covered area to protect the generator and its battery from cold weather.
  • Use proper oil for the temperature expected. Lighter-weight oil (less viscosity) such as synthetic 5W-30 is recommended for cold weather applications.
  • Disengage all possible external loads.
  • Use fresh winter-grade fuel. Winter grade fuel has higher volatility to improve starting.
  • Dual fuel and tri-fuel models: It would be easier to start the engine with gasoline compared to propane (or natural gas) in cold weather.
  • It is recommended to start your engine on gasoline and then switch to propane (or natural gas) if it is hard to start your dual-fuel (or tri-fuel) generator with propane (or natural gas).

Shutdown and Storage

  • Remove any load from the generator.

Short term storage

  • Turn the starting dial switch to the engine stop position.

Long term storage

  • Turn the starting dial switch to the fuel-off position.
  • Turn the starting dial switch to the engine stop position when the engine stops.
  • Turn the fuel valve knob to the OFF position
  • Turn the fuel cap vent lever to the “OFF” position.

Changing Fuels

  • Disconnect all electrical loads from the generator.

Gasoline to propane/LPG

Propane/LPG to Gasoline

  • Connect the LPG gas hose to the propane fuel source.
  • Fully open the Propane/LPG cylinder knob.
  • Make certain the propane tank is fully closed.
  • If the generator is to be stored for longer than 30 days, refer to the operator’s manual for further Instructions.
  • Questions? Call 855-888-3598 or email support@a-ipower.com

Documents / Resources

| A-iPower 801004 Inverter Dual Fuel Generator [pdf] User Guide
801004 Inverter Dual Fuel Generator, 801004, Inverter Dual Fuel Generator, Dual Fuel Generator, Fuel Generator, Generator
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals