Attention: Before using the product, please read these instructions for use carefully.
Always use the latest version. You can find it on our website.

SAFETY INSTRUCTIONS

Please observe the general safety instructions enclosed with the product, these can also be found at service brennenstuhl com The light source is not replaceable, if it loses its function, the complete luminaire must be disposed of.
The outer flexible cable of this luminaire cannot be replaced; if the cable is damaged, the luminaire must be disposed of.
To avoid the risk of strangulation, the flexible cables connected to this luminaire must be fixed to the wall, provided the cables are within reach of the arms.

TECHNICAL DATA

Protection class: I CH version
Rated voltage: 220 – 240 V~, 50/60 Hz Connection cable:
Degree of protection: IP 65 Plug:
Temperature range: – 15 °C to + 40 °C

Compatible connection cables:
Protective sheath
Wire| Ø 7.0 – 9.7 mm
Ø 0.7 – 1.5 mm| |
Type| Motion detector| Nominal power (W)| Max. current (A)| Power factor| Max. proj. area (cm ² )| Dimensions (mm)| Dimensions protection cover (mm)| Weight (kg)
---|---|---|---|---|---|---|---|---
JARO 1060/ JARO 1063| | 10| 0.08| >0.5| 134.5| 119x78x113| 98.8×77.8×4| 0.26
JARO 1060 P/
JARO 1063 P| X| 10| 0.08| >0.5| 177.4| 157x78x113| 98.8×77.8×4| 0.34
JARO 3060/ JARO 3063| | 20| 0.13| >0.7| 204| 136×75.4×150| 133.6×100.6×4| 0.40
JARO 3060 P/
JARO 3063 P| X| 20| 0.13| >0.7| 271.5| 181×75.4×150| 133.6×100.6×4| 0.49
JARO 4060 / JARO 4062/ JARO 4063| | 30| 0.14| >0.9| 318.3| 167.5x82x190| 173.4×133.4×4| 0.65
JARO 4060 P/
JARO 4063 P| X| 30| 0.14| >0.9| 407.6| 214.5x82x190| 173.4×133.4×4| 0.74
JARO 7060 / JARO 7062/ JARO 7063| | 50| 0.24| >0.9| 415.8| 189×84.4×220| 202x154x4| 0.92
JARO 7060 P/
JARO 7063 P| X| 50| 0.24| >0.9| 519.2| 236×84.4×220| 202x154x4| 1.00
JARO 11060 /
JARO 11062 CH| | 80| 0.40| >0.9| 755.2| 256x75x295| 261.2×196.2×4| 1.80
JARO 11060 P| X| 80| 0.40| >0.9| 843.7| 286x75x295| 261.2×196.2×4| 1.89
JARO 14060 /
JARO 14062/ JARO 14063| | 100| 0.49| >0.9| 805.2| 264x75x305| 271.2×206.2×4| 1.94
JARO 20060 /
JARO 20062 /
JARO 20062 4K/
JARO 20063| | 150| 0.74| >0.9| 1108.6| 298x76x372| 340x240x4| 2.78
JARO 27060 /
JARO 27062 CH/
JARO 27062 4K| | 200| 0.98| >0.9| 1321.8| 328x76x403| 375x270x4| 3.49

This product is suitable for indoor and outdoor lighting purposes.

MOUNTING AND CONNECTION TO POWER SUPPLY

Please refer to the illustrations in the Quick Start Guide.

  1. IMPORTANT! (fig. 1) Always switch off the power supply before installation.

  2. The spotlight is delivered with the bracket mounted. For easy installation, it is a good idea to dismantle the bracket of the spotlight and use it as a template for the drilling distance of the holes (fig. 2).

  3. Use the bracket to mark out the drill holes.
    For versions with motion detector: The spotlight must be mounted at a height of less than 3 m (fig. 3). Recommended mounting height for models with motion detector: 2.5 m.

  4. Spotlights without motion detectors can be placed anywhere, but reduced brightness must be expected at a greater distance from the illuminated area.

  5. To fix the mounting plate to the wall, follow the steps as described in fig. 4 to 6.

  6. Now attach the spotlight to the screwed-on bracket (fig. 7).

  7. The swiss version is delivered with the cable connected. Points 8 to 12 can be skipped here.

  8. To connect the spotlight, unscrew the cable lock (fig. 8).

  9. Pay attention to the length specifications when stripping the cable.
    The cable sheathing should be stripped a maximum of 20 mm, the wire insulation 12 to 14 mm (fig. 9). For safety reasons, the PE line should always be longer than the L and N lines! This is enormously important for the tightness of the spotlight.
    The length of the cable should be long enough to allow you to fix the spotlight in any position. In addition, you should make sure that the cable is not routed towards the spotlight from above. We recommend a small bend so that rainwater does not flow along the cable to the spotlight.

  10. Slide the cable lock onto the cable (fig. 9).

  11. Now connect the spotlight. To do this, insert the stripped strands into the respective marked sockets N, L and earth (fig. 10).
    These are automatically tensioned by a spring, it is not necessary to screw them tight. You can release the stranded wire by pressing the button.

  12. Screw the middle part of the cable closure onto the spotlight and then the closing cap (fig. 11).

  13. Adjust the spotlight to the desired beam angle and fix it in place (fig. 12).

  14. Switch on the power supply again.

  15. The motion detector can be adjusted horizontally by 75° and vertically by 70° to the front / 90° to the rear (fig. 16 and 17).

DESCRIPTION OF FUNCTION

(only for versions with motion detector/ PIR)
This spotlight is equipped with an infrared sensor. It switches on automatically as soon as the sensor detects movement in the surroundings.
If possible, do not point the motion detector at swimming pools, heating vents, air conditioners or objects that are subject to large temperature fluctuations.
Avoid pointing the motion detector at trees or bushes or at places where pets might often be present.
The motion detector can be turned horizontally to the right and left and tilted vertically up and down.
When mounting the spotlight, bear in mind that the motion detector is most sensitive to movements that pass across its field of detection and least sensitive to movements that pass directly towards the unit.
Permanent function
The spotlight can be switched on in permanent mode for approx. 4 hours. After 4 hours, the spotlight automatically switches back to normal mode with motion detector.
The permanent function can be activated by switching on three times within 5 seconds (On / Off / On / Off / On). By switching off/ on again, the spotlight is back in motion detector mode.

SETTING THE MOTION DETECTOR (PIR)

There are three controls on the back of the motion detector, see Quick Start Guide figures 19 to 21.
TIME – Time setting (left):
With this control you can select any switch-on time between approx. 10 seconds and 5 minutes after the last movement has been
detected. Turning the TIME control clockwise decreases the time span, counterclockwise increases it.
SENS – Sensitivity setting (middle):
The sensitivity of the sensor depends on the ambient temperature. The lower the ambient temperature, the greater the sensitivity
of the motion detector.
The sensor is most sensitive when the SENS control is turned fully in the (+) direction.
LUX – Light setting (right):
The light setting determines at which brightness the sensor of the spotlight switches on.
The (+) position indicates that the sensor operates during the day and at night, in the (-) position the sensor only operates at night. To adjust, wait until the desired ambient brightness is reached. Turn the light adjustment control all the way to the (-) symbol. Slowly turn the control towards the symbol (+) until the spotlight turns on by movement.
The spotlight will now switch on from the set brightness when motion is detected.

SCOPE OF DELIVERY

Spotlight, 1x mounting set, 1x cable lock IP68.
SPARE PARTS
Spare parts are available on request.
EU-DECLARATION OF CONFORMITY
UK DECLARATION OF CONFORMITY
The declaration of conformity is deposited with the manufacturer.

DISPOSAL

Dispose of electrical appliances in an environmentally friendly way!
Electrical appliances do not belong in household waste!
According to the European Directive 2012/19/EU on waste electrical and electronic equipment, used electrical equipment must be collected separately and recycled in an environmentally sound manner. You can find out how to dispose of your old appliance from your local authority or city council.
For more information please visit the Service/FAQ section on our homepage, www.brennenstuhl.com.

Hugo Brennenstuhl GmbH & Co KG
Seestraße 1 – 3 · D-72074 Tübingen
H. Brennenstuhl S.A.S.
4 rue de Bruxelles ∙ F-67170 Bernolsheim
lectra technik ag
Blegistrasse 13 ∙ CH-6340 Baar
www.brennenstuhl.com
Brennenstuhl UK Ltd.
No 1 Royal Exchange
London EC3V 3DG, UK
0534228/2623

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

brennenstuhl User Manuals

Related Manuals