LEDALITE ID-39 TruGroove Recessed Drywall Trim

LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-
featured

Product Information

Specifications:

  • Product Name: TruGroove Recessed ID-39 Drywall Trim
  • Fixture Type: Linear
  • Mounting: Standalone or Continuous Run in Drywall Ceiling
  • Light Distribution: Symmetric or Asymmetric
  • Lens Options: Flush Lens, Regressed Lens
  • Components: Drywall trim flange, Exterior lens kits, Mounting Kit (390ZA01), Joint Kits (390JK01, 390JK03), Suspension Cable
  • Tools Required: Phillips screwdriver, 5/16 Nut Driver

Product Usage Instructions

Installation Notes:
Before beginning installation, please read all instructions, including fixture/sensor wiring and mechanical details. Make sure to install the fixture in accordance with local and national building and electric codes. Also, ensure that the fixture is connected to the building ground via the provided ground wire before connecting to the mains power supply. Always disconnect or turn off power before attempting any installation, service, or maintenance.

Prepare Ceiling: Standalone Units

  1. Determine Locations: Identify the desired locations for installing the standalone fixtures.
  2. Ceiling Cut-out Details: Measure and mark the cut-out dimensions on the ceiling based on the fixture length and mounting offset. The cut-out length varies depending on the fixture size (2ft, 4ft, 6ft, etc.), while the cut-out width should fall within the range of minimum 3-7/8 and a maximum 4 inches.
  3. Min Max: Ensure that the cut-out dimensions fall within the specified tolerances.
  4. Fixture Length: For 2ft standalone fixtures, make sure to install end framing members 1 inch beyond the ceiling cut-out.
  5. Power Feed: Determine the location for the power feed, ensuring it is positioned at one of the two locations specified.

Prepare Ceiling: Continuous Runs

  1. Determine Locations: Identify the desired locations for installing the continuous run of fixtures.
  2. Ceiling Cut-out Details: Measure and mark the cut-out dimensions on the ceiling based on the fixture length and mounting offset. The cut-out width should fall within the range of minimum 3-7/8 and maximum 4 inches.
  3. Min Max: Ensure that the cut-out dimensions fall within the specified tolerances.

FAQ:

Q: Can I install the fixture in a residential area?
A: This fixture is designed for commercial environments. If installed in a residential area, it may cause harmful interference to radio communications. In such cases, the user will be required to correct the interference at their own expense.

Q: What tools are required for installation?
A: You will need a Phillips screwdriver and a 5/16 Nut Driver.

Q: Are the joint kits required for installation?
A: Yes, one joint kit is required for each joint. The type of joint kit required depends on whether the flush or regressed lens mounting is used and whether symmetric or asymmetric light distribution is desired.

Installation Instructions

Standalone or Continuous Run in Drywall Ceiling

ATTENTION : Install in accordance with local and national building and electric codes. These instructions review how to install drywall trim versions of TruGroove recessed fixtures. Please refer to layout drawings supplied by Ledalite in conjunction with these installation instructions. The graphics below show the components required

IMPORTANT : Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation

LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(1\)LEDALITE-ID-39 -TruGroove
-Recessed-Drywall -Trim-fig- \(2\)

  • Note : One kit required for each joint. Joint kit determined by flush or regressed lens mounting and symmetric or asymmetric light distribution.

Tools : Phillips screwdriver, 5/16” Nut Driver

ATTENTION : Install in accordance with local and national building and electric codes

TruGroove Drywall Trim Installation Instructions

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Important Notes

  1. Installation Notes

    • ‘C’ Channels (or equivalent) must be properly braced to ensure accuracy of cut-out in drywall.
    • Use appropriate tools to outline specified dimensions of ceiling cut-out to ensure straightness of cutting.
    • Lens will not insert properly if fixture trim has mud or paint build-up.

Warning, Shock Hazard
Fixture must be connected to building ground via the provided ground wire before connecting to mains power supply. Disconnect or turn off power before attempting any installation, service or maintenance.

Avoid The straightness and accuracy of the cut-out in the drywall is crucial in ensuring proper fit for the fixture.

NOTE : TruGroove modules are designed for installation after ceiling construction.

Installation Preparation

Prepare Ceiling: Standalone Units
  1. Determine Locations

    • Determine fixture location and fixture type. Refer to figure A for cut-out length and mount locations. Install mount brackets and suspension cables as shown on page 3.

    • Determine power feed location(s) -refer to figure A. Install power feeds as required and drop below-installed ceiling height.

    • Build ceiling frame around fixture cutout to 3-7/8″ to 4″ width as shown in figure
      Important : The cut-out MUST fall within the specified tolerances.

    • Ceiling Cut-out DetailsLEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig- \(4\) Important: For 2ft standalone fixtures, end framing members must be installed 1” beyond ceiling cut-out.
      ATTENTION : Install in accordance with local and national building and electric codes. Revision C

  2. Determine Locations

    • Determine fixture location and fixture type. Refer to figure B for mount locations and cut-out length. Install mount brackets and suspension cables as shown below.
    • Determine power feed location(s) -refer to layout drawings. Install power feeds as required and drop below installed ceiling height.
    • Build ceiling frame around fixture cut-out to 3-7/8″ to 4″ width as shown in figure B. Refer to layout drawings for ceiling frame length.
      Ceiling Cut-out DetailsLEDALITE-ID-39 -TruGroove -Recessed-Drywall
-Trim-fig- \(5\) For continuous run fixtures, the cut-out in the drywall ceiling should be the same size as the overall fixture run length indicated on the layout drawings +1/4 “.
  3. Mount Kit
    Install mounting brackets, suspension cables and power feed(s) at required locations. Mounting hardware (screws/ fasteners) are supplied by others. Maximum screw size # 10 (.190”).

  4. Install Mounts and Power Cables
    Install a ‘C’ channel perimeter around the ceiling cutout.
    Important : See ceiling cut-out details on page 2 & 3.

  5. Install Drywall Ceiling
    Install drywall ceiling and cut required opening as shown in figure A on page 2 or figure B on page 3.LEDALITE-ID-39 -TruGroove -Recessed-Drywall
-Trim-fig- \(6\) Install fixtures

  6. Prepare Fixtures
    Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings. Match up each fixture based on the spec tag and ID number labelled on each fixture box for the specified run.

  7. Insert Aircraft Cable
    Suspend each module by inserting the aircraft cables through the grippers on top of the housing.

  8. Raise Fixture
    Gradually lift each module to approximately 12 inches below the ceiling .LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(7\)

  9. Remove Cover and Feed through Power Wire
    At the power location(s), remove factory installed wire cover. Feed power wires through. Complete all wiring connections.

  10. Re-install Wire Cover
    Re-install wire cover and slide to lock. Install screw.

  11. Raise and Level Fixtures
    Once the power connections are complete, pull the aircraft cable to raise all modules to just below the ceiling.
    Important : Modules must be level relative to each other if joining of sections is requiredLEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(8\)

  12. Install Joiner Aligners
    At joint location(s), gently tap provided joiner aligners inside one module only. Two joiner aligners are required for each joint.
    Important : To insert aligners, tap gently with a hammer until half is inserted into the joiner channel. Be sure to engage the dimple.

  13. Complete  answering
    Complete module-to-module wiring connections and carefully tuck all wires inside the upper wiring cavity.
    Important : Pay attention that the fixture-to-fixture ground wire is connected.

  14. Join Individual Modules
    Gently slide housing modules together, ensuring joiner aligners are engaged inside the trim in the adjacent module.
    Important : Joiner aligners must be fully inserted to provide proper section alignment.LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(9\)

  15. Install Joiner Brackets
    Install joiner brackets on each side of the housing using supplied hardware. Important: Hand tighten bracket screws while supporting the housing on the opposite side. Gradually alternate sides while tightening.
    Do not over tighten.

  16. Raise Fixture(s) into Ceiling Cut-out
    Important: For continuous row modules, start at one end and gradually raise each module up one inch at a time. Repeat process until housing is fully recessed and housing trim touches drywall ceiling. Do not stress the joint connection by tilting the module, as damage can occur.

  17. Trim Excess Cable
    Trim suspension cable approximately 8 inches below the ceiling level. Tuck all excess cable inside the upper wiring cavity.LEDALITE-ID-39 -TruGroove
-Recessed-Drywall -Trim-fig- \(10\)

  18. Secure Joint Cover

  19. Flush lens and Symmetric
    At joint location(s), secure joint covers using Philips screwdriver and supplied hardware. Ensure cover plates sit flush with bottom reflectors for proper LED board fit.

  20. Secure Joint Cover
    Regressed lens or Asymmetric At joint location(s), secure joint covers using Philips screwdriver and supplied hardware. Ensure cover plates sit flush with bottom reflectors for proper LED board fit.LEDALITE-ID-39 -TruGroove
-Recessed-Drywall -Trim-fig- \(11\)

  21. Flush Lens Installation and Removal

  22. Flush Lens: Snap in lens into fixture.
    Lens Removal: To remove snap-in lens for maintenance purposes, insert a flat, smooth edged object between lens and housing. Twist to release pressure and remove lens.

  23. Regressed Lens Installation
    Regressed Lens:
    Angle lens to insert into fixture. Lay lens on aluminum extrusion flange.
    Ensure lens engages between lens retaining clips to prevent movement of lens .LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(12\)

Sensors in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures. Note:
    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig- \(13\)

Multiple Sensors Controlling Separate Zones in a Row

Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
Notes:

  • * A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
    • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig- \(14\)

Sensor Spacing

  • For correct operation, sensors should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

LEDALITE-ID-39 -TruGroove -Recessed-Drywall -Trim-fig-
\(15\)

Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage:
Note : Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.

Daylight sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (person moving ≤3ft/s or 0.9m/s).
  • Major movement (person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response

© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

  • www.ledalite.com
  • Signify North America Corporation
  • 400 Crossing Bivd, Suite 600
  • Bridgewater. NJ 08807
  • Telephone: 855-486-2216
  • Signify Canada Ltd.
  • 281 Hillmount Road,
  • Markham. ON. Canada L6C 2S3
  • Telephone: 800-668-9008

All trademarks are owned by Signify Holding or their respective owners.
www.signify.com