INTRODUCTION

Thank you for opting for Konner & Sohnen® products. This manual contains a brief description of safety,
setup and use. More information can be found on the official importer’s website in the support section: Ekonner-sohnen.com/manuals
YouCan also go to the support section and download the manual by scanning the QR code or on thewebsite of the official importer of Konner & Sohnen® at www .konner-sohnen.com

Please, read this manual carefully before use!

https://koenner-soehnen.com/de/manuals

The manufacturer of Konner & Sohnen® producs reserves the right to make changes that may not be
reflected in this manual, namely:

  • The manufacturer reserves the right to make changes in the produd design, configuration and construction.
  • The images and drawings in this manual are for reference only and may differ from the actual components and inscriptions on the products.

Contact information that you are free to use in case of any problems can be found at the end of this manual. All information in this manual is correct to the best of our knowledge and belief at the date of its publication. The current list of serice centers can be found on the official importer’s website at www.konner-sohnen.com

ATTENTION – DANGER! Failure to follow the recommendations marked with this sign may lead to serious injury or death of the operator or third parties.
IMPORTANT! A Useful information while operating the machine.

SAFETY INFORMATION

IMPORTANT! Carefully read this manual before starting to work with the generator

WORKING AREA

  • Please don’t use the generator near flammable gases, liquids or dust. When using the generator exhaust system gets very hot. This may cause fire or explosion of these materials.
  • Be sure to follow cleanliness and good lighting in the work area. Clutter and poor lighting may cause an injury.
  • Do not et the presence of unauthorized persons, children or animals when working with generator. If necessary, make sure to fencing the working area.

ELECTRICAL SAFETY

  • The generator produces electricity that may lead to an electric shock while neglecting compliance regulations.
  • In the high humidity level conditions generator exploit is prohibited. Keep the generator in a dry place only.
  • Avoid direct contact with grounded surfaces (pipes, radiators, etc.).
  • Be careful when working with power cables. Immediately replace itin case of damage, as damaged wire increases the risk of electric shock.
  • All connecting the generator to the network must be made by certified electrician in accordance with all electrical rules and regulations.
  • Connect the generator to the protective ground before operation.
  • Do not connect or disconnect a generator to electricity consumers, which are placed in water on a wet or damp soil.
  • Do not touch parts of the generator under voltage.
  • Connect the generator to those customers only which meet the eledrical characteristics and the rated poweer of the generator.
  • Store all electrical equipment dry and clean. Wires with damaged or spoiled insulation should be replaced. You should also replace worn, damaged or rusty contacts.

PERSONAL SAFETY

  • Be careful. Do not operate the generator, if you are tired, under the influence of drugs or alcohol. Inattention may cause a serious injury.
  • Avoid inadvertent start. Make sure to set the switch to Offwhen you turn off the generator.
  • Make sure no outsider objects are on the generator whenitis turned on.
  • Always keep astable position and balance when starting the generator.
  • Do not overload the generator, use it only for the purpose.
  • As exhaust gases contain poisonous carbon dioxide (C0,) and carbon monoxide (CO) gases which are dangerous for lfe, itis strictly forbidden to install the generator in residential buildings, premises connected to residential buildings by a common ventilation system, other rooms from which exhaust gases may enter living premises.

OPERATING AND MAINTAINING THE GENERATOR

  • Before you start checks before operating, make sure that the generator is on a flat level surface and the engine switch is setto OFF.
  • Check the connection of moving fians, no damaged parts that affect the operation of the generator. If the generator is damaged, remove them before using.
  • For repair and maintenance use only recommended oil fuel. Using other lubricants, spare parts and consumables deprives you of warranty apparatus.
  • Servicing the generator should be crried out only by qualified personnel. The current list of service centers you can find at the website of official importer: www.koenner-soehnen.com
  • Keep the generator dry, well ventilated place if you are not usingiit.

ATTENTION DANGER
The generator runs on automative diesel fuel and conform to European quality standards not lower than Euro 5 emission standard. The generator runs on auto motive diesel fuel. Do not use gasoline, kerosene, fuel ol ISOHNEN as fuel. Diesel fuel type should correspond the operating season.
The use of low-grade fuel can lead to a degradation of the manufacturer’s declared specfications or to engine failure. Do not add any chemical additives to diesel fuel and do not mix diesel fuel with used engine oil or fuel oll.

Diesel fuel characteristics Region of use
EN590:96 European Union
BS 2869-A1 or A2 Great Britain

Keep the fuel tank and refueling accessories clean and neat and ensure that no foreign objects / debris get into the fuel tank when refueling the generator. Sulfur content should not exceed 0.5% (less than 0.05% is recommended). Sediment and water content in  fuel should not exceed 0.05%. A cetane number of at least 45 must be ensured. For example, hiodiesel fuel which is known under the B5 brand, is permitted. This type fuel should contain no more than 5% of fatty acid methyl esters (FAME) and 95% of mineral diesel fuel. Read more about the requirements for biodiesel in the full web version: konner- sohnen.com/manuals

SAFETY SYMBOLS. DESCRIPTION OF SAFETY SYMBOLS WHEN OPERATING THE GENERATOR

MAIN OVERVEW

  1. Reinforced steel frame
  2. Fuel level indicator
  3. Fuel tank cap
  4. Control panel
  5. Battery
  6. Wheels
  7. Fuel pump
  8. Antivibration supports.
  9. Transport handle
  10. Engine

IMPROTANT
Manufacturer reserves the right to make changes and/ or improvements in design, components set and technical attributes without notice and without incurring obligation. The pictures in this manual are schematical and may not match the parameters of original product.

PACKAGE INCLUDE:

  • Packaging
  • Generator
  • Owner’s manual
  • 16APlugs- 2 pcs.
  • 32APlug – 1 pc (for model KS 6100iDE ATSR)
  • 63APlug -1 pe (for model KS 9500iDEATSR)
  • Wheels – 2 pes.
  • Wheel axles – 2 pcs.
  • Locking clamps for wheel axle – 2 pcs.
  • Washers for wheel axle – 2 pcs.
  • Handle bars-2 pcs.
  • Antivibration supports – 2 pes.
  • 12V Adapter to USB – 1 pc
  • Remote control (for model KS 9500iDE ATSR)

CONTROL PANEL

  1. Preheater
  2. Grcuit breaker 12V
  3. Gircuit breaker 230V (164)
  4. Multifundional LED display
  5. 1x32AACoutlet
  6. Gircuit breaker 230V
  7. 216AACoutlets
  8. Earthing holt
  9. 12/8.3A DC outlet
  10. Reset bunnn
  11. ATS input
  12. Overload indicator
  13. Ol level indicator
  14. ATS input button
  15. Engine switch(START for model KS 6100iDE ATSR)
  16. 1x63A AC outlet
  17. START/STOP button

TECHNICAL DATA

Model KS 6100iDЕ ATSR KS 9500iDE ATSR
Voltage 230 V 230 V
Max power 5,5 kW 10,0 kW
Nominal power 5,0 kW 9,5 kW
Frequency 50 Hz 50 Hz
Current max 23,9 А 43,5 А
Outlets 2×16А, 1×32A 2×16А, 1×63A
Fuel tank volume 18 l 18 l
**50% power working time*** 19 h 14 h
Multifunctional LED-display voltage, frequency, current, output power,

hour
Noise level (Lwa)| 97 dB| 97 dB
Power output| 12V/8,3А| 12V/8,3А
Engine model| KS 480iD| KS 790iD
Engine type| diesel powered one-cylinder, four-stroke air-cooled
Engine power| 6,5 kW/8,8 hp| 13 kW/17,7 hp
Crank case volume| 1,65 l| 1,8 l
Engine cylinder volume| 456 cm3| 762 cm3
Preheater| +| +
Engine start| manual/electric| electric
Power factor| cosφ 1.0 (230V)| cosφ 1.0 (230V)
Frame diameter| reinforced steel frame 28 mm
Battery| 28 Ah| 36 Ah
Output for ATS| +| +
Dimensions (L×W×H)| 675×525×665 mm| 820×555×745 mm
Net weight| 97 kg| 130 kg
Protection class| IP23M| IP23M
Altitude (MAX)| 1000 m| 1000 m
Acceptable deviation of a current is 10%

“Fuel consumption depends on many factors, such as load, fuel quality, season, altitude, technical condition of the generator.
LwA is guaranteed sound power level. This indicator is measured in the immediate vicinity of the noise maker.
The optimum operating conditions are ambient temperature of 17°C — 25°C, barometric pressure of 0.1 MPa (760 mm Hg), and relative humidity of 50 — 60%. Under such ambient conditions, the generator can guarantee maximum performance in terms of the stated specifications. In case of deviations from the above ambient values, the performance of the generator can be different.
Please note that in order to preserve the lifespan of the generator, continuous loads should not exceed 80% of the rated power.

TERMS OF USE

When starting operating the generator, its recommended to ground it. Before starting the unit, remember that the total power of consumers connected should not exceed the rated capacity of the generator.

TYPES OF CONSUMERS AND INRUSH CURRENT
Consumers (electrical devices connected to the generator) are divided into active and reactive ones. Adive ones are those, which energy is converted into heat (heating devices).
Reactive are all consumers with electric motor. When you run the engine, starting currents occur briefly, the size of which depends on engine design and purpose. Please consider those starting currents when choosing a generator.
Most electric tools have starting current ratio 2-3. This means that when you tumn such tools required generator power have 2-3 times more power load. The biggest factor of inrush current have such consumers as.
compressors, pumps, washing machines.

BEFORE STARTING

The generator is supplied without fuel. Before the operation please fill the fuel. Guidelines for filling are below. Generators are supplied without motor oil. The generator casing may contain residues of oil after tests conducted during production.
Before starting to use the generator, be sure to pour oil. Recommendations on oil and it’s filling process are below. Follow maintenance recommendations during the first month or twenty hours (whichever occurs first) contained in the “Maintenance” section.
CHECK THE FUEL LEVEL

  1. Remove the fuel tank cap and chedk the fuel level.
  2. Fill fuel to the level of the fuel filter and make sure there is no air in the fuel system.
  3. Screw the fuel tank cap back tightly.

CHECKTHE OIL LEVEL

  1. Unscrew the oil level gage and clean it with lean dloth.
  2. Put the oil gage back without screwing it.
  3. Take the oil level gage outand check the oil level according tothe mark on a gage.
  4. Add ol ifit’s level is belowthe mark on a gage.
  5. Screw the oil gage back.

For commissioning models with elektrostart please charge the battery. Please use additional battery charger (notincluded) to charge the battery or let the generator work at least one hour at 50% load at the first start.

IMPORTANT! Diesel fuel type should correspond the operating season.

STARTING TO WORK

Before starting the engine, make sure that the rated power of power consumers matches with the poweer of generator. Do not exceed the nominal power of the generator. Do not connect the device before starting the engine!
ATTENTION – DANGER!
Do ot change the configuration of the amount of fuel or speed controllers this adjustment was mate before the sale). Otherwise, there will be possible changes in the engine work or breakage. Any changes to the design of the generator will void the warranty service!
ATTENTION – DANGER!
Do not let the generator work more than 30 minutes in range from nominal to maximum.

This material is for informational purposes only and is not an instruction how to install or connect equipment to the network. In practice, there are different options for supplying electricity and different rules for its connection. The decision on how to properly connect the equipment in each individual case must be made by a certified electrician who performs the installation and electrical connection of the equipment.
The manufacturer is not responsible for improper connection of equipment, and is not responsible for possible material and physical damage that may occur as a result of improper installation, connection or operation of equipment.
L”EW&HNZO OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD BE MET:

  1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal (operating) power of the device.
  2. After the first 20 operating hours, be sureto change the oil. It s better to drain oil while the engine is stll hot after operation to ensure quick and complete oil draining.
  3. Check and clean the air filter and fuel flter.

MANUAL START (FOR MODEL KS 6100iDE ATSR)

  1. Check the fuel level
  2. Checkthe oil level
  3. Do not connect any load to the generator prior to starting the engine.
  4. Attach the terminals to the battery, ensuring the correct polarity of “positive to positive” and “negative to negative.”
  5. Set the engine emergency shutdown lever (fig 1) in the ON position.
  6. Switch the ATS SWITCH button to the OFF position.
  7. Pull the starter handle until you feel resistance.
  8. There is an upemnghun the top cover of (he‘generamr. Thmufih this opening, press the decompression lever (fig. 2), located at the top of the cylinder head, to reduce cylinder pressure and fadlitate engine starting.
  9. Switch the ENGINE SWITCH button to the RUN position.
  10. Sharply pull the starter handle; the engine will start.
  11. Do not allow the starter handle to snap backinto the engine. To prevent damage of the starter, return itto its initial position gently.
  12. Letthe generator work for 1-2 minutes, then flip the circuit breaker (emergency stop switch) to the ON (UP) position.

ELECTRIC START

  1. Check the fuel level
  2. Checkthe oil level
  3. Do not connect any load to the generator prior to starting the engine.
  4. Attach the terminals to the battery, ensuring the correct polarity of “positive to positive” and “negative to negative.”
  5. Set the engine emergency shutdown lever (fig. 1) to the ON position.
  6. Switch the ATS SWITCH button to the OFF position.
  7. There is an opening on the top cover of the generator. Through this opening press the decompression lever (fig. 2), located at the top of the cylinder head, to reduce glinder pressure and facilitate engine starting.
  8. For the KS 6100iDE ATSR model, move the Engine Switch to the START position and hold it there for a few seconds until the engine starts. Release the button and it will automatically return to the RUN position.
  9. Forthe KS 9500iDE ATSR model, move the Engine Switch to the ON position and press the START button, engine will start.
  10. If the engine does not start after holding the START button for 5 seconds, wait 15 seconds before attempting to start again. Prolonged use of the starting system can deplete the battery.
  11. Let the generator work for 1-2 minutes, then flip the circuit breaker (emergency stop switch) to the ON (UP) position.

IMPORTANT! If engine does not start after three or four attempts, it may mean that the fuel system has some air inside. Remove the air from the fuel system (drain the diesel fuel, with the fuel there will be excess of air).
ATTENTION – DANGER! Do not let the simultaneous connection of two or more devices. Start of many devices requires large power capacity
Devices are to be connected in turns, according to its maximum allowed power. Do not connect the consumers in first 1-2 minutes after the generator start. Do not stop the generator, if there are any devices connected. This may result to generator breakdown.
Before turning the generator on, verify that the connected devices are in working order. If the connected device suddenly stops running — turn the power off by means of an emergenqy switch, disconnect the device and checkit.
IMPORTANT! DISCONNECT ALL DEVICES BEFORE STOPPING THE SEVERATOR Do ot st the senerator with the devic es turned on. This may disable the generator or devices connected o it

STARTING WITH ELECTRIC STARTER IN THE COLD SEASON

  • When the air temperature is lower than +50C itis necessary to use the “Preheater” function when starting.
  • Turn the ENGINE SWITCH button to the ON position (for model KS 9500iDE ATSR) or RUN position (for model KS 6100iDE ATSR) and press the PREHEATER button. While holdingit, press START.

IMPORTANT!   Do not hold the button “Preheater” more than 10 seconds, it may cause the failure of incandescent candles

DURING GENERATOR OPERATION:

  • You can use the generator if the voltmeter shows 230+10% (50 Hz).
  • Watch the voltage meter and in case of excessive indices values, stop the generator operation.
  • Upon accumulator unit recharge, it is mandatory to verify the polarity correctness (+to +, -to- ).
  • Charging device wires have to be at first connected to the accumulator unit and only then – to the generator itself. All “generator to network” connections are to be carried out by a certified electridan. Any mistakes may result in serious equipment damage.
  • Itis forbidden to use 12V voltage simultaneously with 230V.

ENGINE SHUTDOWN PROCEDURE

  1. Disconnect all devices connected to the generator.
  2. Allow the generator to run for 3 minutes without load to cool down.
  3. For the KS 9500iDE ATSR model, press the round START/STOP button and move the ENGINE SWITCH to the OFF position.
  4. Forthe KS 6100IDE ATSR model, move the ENGINE SWITCH to the OFF position.
  5. Set the protective circuit breaker on the panel of the generator to the OFF position.
  6. The engine emergency shutdown lever (see fig. 1) should only be used to stop the engine in cases of extreme necessity.

CCONNECTING DEVICES
Do not let the generator work more than 30 minutes in range from nominal to maximum.
After starting the engine, make sure the voltmeter readings correspond tothe nominal (at50 Hz230V10%).

STARTING THE GENERATOR USING THEATS UNIT
When starting the generator in automatic or manual mode using the ATS unit (automatic transfer switch), the button ENGINE SWITCH on the generator control panel must e in the ON/RUN position.
IMPORTANT! Failure to follow these instructions may lead to damage A of the rotor and stator windings, the ATS unit.

TECHNICAL MAINTENANCE WORKS

Works, spedified in “Technical maintenance” section, are to be regularly performed. If the the generator user has no possibility to perform regular maintenance independently, itis necessary to address the official service centerto registrate an order for such works performance.
IMPORTANT!   In case of any damages, occurred due to non-performance of regular maintenance works, the manufacturer bears no responsibility for such damages.

SUCH DAMAGES ARE ALSO:

  • Damages occurred as a result of using non original spare parts;
  • Corrosion damages and other results of improper equipment storage;
  • Damages occures asa result of maintenance performance by inexperienced and unauthorized specialists.

MANUAL COMPLIANCE
Technical maintenance, operation and Kénner & Séhnen® generator storage are to be performed according tothis manual recommendations. Manufacturer bears no responsibility for damages and losses, caused by incompliance to safety requirements and technical maintenance rules.

FIRST OF ALL THIS APPLIES TO:

  • use of lubricants, gasoline and motor oils, forbidden by the manufacturer;
  • device technical alterations;
  • equipment operations againstits intended use;
  • indirect damages, caused by operating faulty equipment;

This manual compliance! You can find a st of service center addresses on the website of exclusive importer: www.konner-sohnen.com 

TECHNICAL MAINTENANCE WORKS

**Node| ****Service type| ****Every start| ****Commissioning (first 20 hours)| ****Each 3 months or after 50 working hrs| ****Each 6 months or after 100 working hrs**
---|---|---|---|---|---


Motor oil

| Check the level| | | |
Replace| |
| ****|


Air filter

| Check/Clean out| | | |
Replace| | | | **
Oil filter| Clean out| | **| ****|


Fuel tank

| Check the level| | | |
Check/Clean out| |
| | ****


Fuel filter

| Check/Clean out| | | |
Replace| | | | ****

RECOMMENDED OILS

Motor oil has a serious impact on performance characteristics and is a major attribute, defining its service life. Use oils designed for four-stroke cyde vehicle engines SAE 10W-30, SAE 10W-40, since such ol contain dearningadditives, which comply or even exceed SE standards accordingto AP dlassification (or equivalent).
Motor oils with other viscosity levels, may be used only if the average air temperature in your region does not exceed the limits of the temperature range, speified in the table. Oil viscosity according to SAE standards or service category, are specified on the AP capacity sticker.

ENGINE OIL REPLACEMENT OR ADDING
Upon ol level decrease it is necessary to add the required quantity in order to provide the correct generator operation.
It is necessary to check the oil levels according to technical maintenance schedule. When changing the oil, remove the oil filter, flush it with gasoline and install it back.

TO DRAIN THE OIL:

  1. Place adrain ofl holding tank under the engine.
  2. Turn the drain cap, located under the oil-depth gage cap in the engine, by means of a 10mm hexagon spanner.
  3. Wait il the il drains.
  4. Putthe drain cap back and tighten it well.

OIL FILLING:

  1. Make sure that the generator is set on flat level surface.
  2. Unscrew the oil gage cap on the engine.
  3. Bymeans of a funnel, pour the advanced purification engine ail to the crankcase. The funnel is not induded. Oil level after filling has to be close to the upper part of ail filler.

AIR FILTER MAINTENANCE

It s necessary to check the air filter from time to time and dean any contaminations. Regular air filter maintenance is necessary to maintain sufficent carburetor air inflow.
The air filter should be cleaned more often when using ‘generator in dusty conditions.

ATTENTION – DANGER!
Never run the engine with the air filter removed or without the filter. Otherwise dirt and dust lead to rapid breakage of engine parts. Failure in this case will not be repaired.
IMPORTANT!
Air_filter replacement is to be performed each 50-100 hours of the generator operation (every 10 hours in unusually dusty conditions).

FUEL FILTER TECHNICAL MAINTENANCE

There are two kinds of fuel filters in Kénner & Sthnen® diesel generators. They prevent the ingress of contaminants from diesel fuel to the engine.
COARSE CLEANING FUEL FILTER
Remove the filter after the possible hard particles hit every 500 operating hours. Never use water for purification the filter.

  1. Remove the fuel cap.
  2. Remove the fuel filter.
  3. Use diesel fuel to clean the filter.
  4. Putthe filter back to the fuel tank.

THE FUEL FILTER IN THE FUEL SUPPLY PIPELINE

This filter has to be replaced every 100 operating hours. It’s located under the fuel tank on the fuel hose through which fuel enters the engine from the tank. To replace it:

  1. Loosen the metal hose damps, located next to the fuel valve to drain the fuel.
  2. Drain the fuel to some spedial volume.
  3. Loosen metal staples on both sides of the fuel fiter.
  4. Remove the filter.
  5. Install new filter, paying attention to the arrow shown. The filter should be installed i the fuel passage diredtion.
  6. Tighten the bracket on the fuel hose.

ATTENTION – DANGER!
Keep an eye on the position of the fuel flte, it should be located to the maximum upright.

ACCUMULATOR MAINTENANCE

In Konner & Séhnen® models with electric start you should periodically perform battery voltage checks.
The generator battery has a voltage of 12V and if the voltage is lower, you should perform battery charging with the help of an external charger.
To avoid discharging the battery, it is recommended to run the generator at least once a month for 30 minutes. If the generator is not used for a long time, please disconnect the battery from the terminals. The battery that comes with the generator does not require additional maintenance and filling of electrolyte.
The generator battery s not subject to service. ff the generator is not used for a long time, the battery may fail. To prolong battery ife itis recommended to do battery charging with an external device (not included) every three months.
Battery warranted – three months from the date of purchase of the generator.

GENERATOR STORAGE

Storage room has to be dry and free from dust deposits. Storage room also has to be locked away from children.

IMPORTANT!
Warning!
Generator is to remain ready for operation at all times. Therefore in case of device malfunctions, they are to b repaired before dismounting the generator for storage.

LONG-TERM STORAGE
If youdo not plan to use the generator for along time, we recommend:

  • Drain the fuel from the tank.
  • Drainthe oil from the engine.
  • Pull the manual starter until you feel light resistance so that the intake and exhaustvalves are closed.
  • Remove the negative terminal of the battery for the electric start models.
  • (lean generator from dirtand dust.

When starting the generator after long storage, follow all procedures in reverse order.
IMPORTANT! Pay attention to the fact that upon failed attempts to launch the generator by means of an electric start, the accumulator units may turn out de-energized, therefore prior to operation start it may be necessary to perform full accumulator nit charging.

BATTERY AND GENERATOR DISPOSAL

To prevent environment damage generator and battery should be separated from ordinary waste. Please recyde them in the safest way, passing it to special place for disposal.

POSSIBLE FAILURES AND SOLUTIONS

Typical failures Possible reason Solution
Engine does not start Engine starting swich set to OFF position

Set the engine starting switch to ON
No fuel| Add fuel
Low-quality or dirty fuel is in engine| Change the fuel
Low engine power / heavy starting| Dirt in fuel tank| Clean the fuel tank
Air filter is dirty| Change the air filter
Water or air in the fuel line| Pump the fuel line
Engine is overheated| Cooling fins are dirty| Clean the cooling fins
Air filter is dirty| Change the air filter
No voltage while engine is working| Circuit breaker is active| Turn on the circuit breaker
Connected cables are corrupted| Check the cables; if using extension cord, change it
Plugged device failure| Try to connect other devices
Connected devices are not working while generator is running| Generator is overloaded| Unplug some devices to reduce load
Short circuit occurred in one of the devices connected| Unplug that device to restore the stability of a system
Air filter is dirty| Change the air filter
Repetitions of an engine are lower than nominal| Contact the service center

AVERAGE POWER USAGE

Device Average power usage, W
Iron 500-1100
Air hair dryer 450-1200
Coffee machine 800-1500
Electric cooking stove 800-1800
Toaster 600-1500
Air heater 1000-2000
Vacuum cleaner 400-1000
Radio 50-250
BBQ Grill electric device 1200-2300
Oven 1000-2000
Refrigerator 100-150
TV set 100-400
Hammer drill 600-1400
Drill 400-800
Freezer 100-400
Grinding machine 300-1100
Circular saw 750-1600
Angle grinder 650-2200
Electro jigsaw 250-700
Electro planer 400-1000
Compressor 750-3000
Water pump 750-3900
Electric sawing machine 1800-4000
Electric lawn 750-3000
Electric powered engines 550-5000
Electric fan 750-1700
High pressure machine 2000-4000
Air conditioner 1000-5000

WARRANTY SERVICE TERMS

The international manufacturer warranty is1 year or 1000 hours (whichever comes first). The warranty period starts from the date of purchase. In cases when warranty period is longer than 1 year according to local legislation please contact your local dealer. The Seller which sells the product is responsible for frammg(he warranty. Please contact the Seller for warranty. Within the warranty period, if the product ails because of defects in the production process, it will be exchanged on the same product or repaired.
The warranty card should be kept throughout the warranty period. In case of warranty card loss, a second one will not be provided. The customer must provide the warranty card and buyer *s check during request for repair or exchange. Otherwise, the warranty service will not be provided. The warranty card, attached to the product during sale, should be correctly and fully completed by the retailer and customer, signed and stamped. In other cases, warranty is not considered as valid.
Provide clean product to the service center. Parts, that must be replaced, are the property of the service center.

EC Declaration of Conformity
Nr. 184

The following products have been tested by us with the listed standards and found in compliance with the European Community Machinery Directive 2006/42/EC, Electromagnetic compatibility Directive (EMC) 2014/30/EC, Noise Directive 2000/14/EC.

Manufacturer: DIMAX INTERNATIONAL GmbH
Address: Flinger Broich 203, 40235 Duesseldorf, Germany
Product: Diesel inverter generator “Kénner & Séhnen”
Type / Model: KS 6100iDE ATSR, KS 9500iDE ATSR
The statement is based on a single evaluation of above mentioned preducts. It does not imply an assessment of the whele preduction and does not permit the use ef the test lab. logo. The manufacturer should ensure that all product in series productien are in conformity with the product sample detalied in this report. The applicant should held the whole technical report at disposal of the cempetent all the right.

Applied EC Directives:   2006/42/EC Machinery Directive
2014/30/EC Electromagnetic compatibility Directive (EMC)
2000/14/EC Noise Directive
(EU) 2016/1628 Non-Road mebile machinery emissions
Applied Standards:
EN ISO 8528-13:2016,
ISO 8528-10:1998
EN ISO 3744:1995,
EN 55@12:2007+A1:2009

Diesel engines KS 480iD, KS 790iD correspend to European Emission Standard Euro V (STAGE V).
This is confirmed by EU TYPE-APPROVAL CERTIFICATE issued by department of transport of Madrid, Spain.
Technical service responsible for carrying out the test -IDIADA.
Date of test reports 22/11/2022

2000/14/EG_2005/88/EG Annex VI
For model KS 6100iDE ATSR Noise measured Lwa = 94 dB (A), guaranteed Lwa = 97 dB (A)
For model KS 9500iDE ATSR Noise measured Lwa = 95 dB (A), guaranteed Lwa = 97 dB (A)

Issued Date: 2024-03-20
Place of issue: Duesseldorf
Director: Fomin P.

International GmbH
Flinger Broich 203 40235 Dusseldorf
USt-ID DE296177274
koenner-soennen.com

We DIMAX INTERNATIONAL GmbH hereby declare that specified above conforms covering European Parliament and Council Directives, 2006/42/EC of 17 May 2006 Machinery Directive, Electromagnetic compatibility Directive (EMC) 2014/30/EC of 26 February 2014, Noise Directive 2000/14/EC of 8 May 2000. The CE mark above can be used under the responsibility of manufacturer. After completion of an EC declaration of Conformity and compliance with all relevant EC directives.

CONTACTS
Deutschland: DIMAX International GmbH Flinger Broich 203 -FortunaPark-40235 Dusseldorf, Deutschland konner-sohnen.com
lhre Bestellungen roers@dimaxgroup.de
Kundendienst, technische Fragen und UnterstOtzung support@dimaxgroup.de
Garantle, Reparatur und Service service@dimaxgroup.de
Sonstlges info@dimaxgroup.de
Polska : DIMAX International Poland Sp.z o.o. Poludniowa 8, 05-830, Stara Wie& Polska, konner-sohnen.com info.pl@dimaxgroup.de
Ykpaina: TOB «TexHo TpdA KC», syn. EnexrporexHitiHa 47, 02222, M. KM113, YKpallia konner-sohnen.com sales@ks- power.com.ua

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals