LEDALITE 4FT Tru Groove Wall Healthcare Instruction Manual
- May 15, 2024
- LEDALITE
Table of Contents
- LEDALITE 4FT Tru Groove Wall Healthcare
- Specifications
- Product Usage Instructions
- FAQ
- System Overview
- Module Lengths
- Tools Required
- Mount Spacing
- INSTALLATION INSTRUCTION
- Sensor in Rows
- Occupancy Sensor Coverage
- Daylight Sensor
- Photosensor spatial response
- ABOUT COMPANY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 8-32 x 3/8” screws (x2)
- 10-32 x 3/4” (x2)
- 10-32 hex lock nut (x2)
LEDALITE 4FT Tru Groove Wall Healthcare
Specifications
- Module Lengths:
- 4ft Module: 48 inches
- 6ft Module: 72 inches
- 8ft Module: 96 inches
- Mount Spacing:
- Use 2 brackets for each 4ft module
- Use 3 brackets for each 6ft and 8ft module
- Wall brackets must be installed a maximum of 12 inches away from fixture ends
- Tools Required : Refer to supplied suspended TruGroove installation instructions for tools required
Product Usage Instructions
-
Arrange boxed fixture on the floor in the specified mounting location and remove fixtures from boxes.
-
Lens Removal:
Remove lens from fixture and set aside using cotton gloves in a clean environment. -
Install Wall Bracket:
- Align the center of the utility box with the center of the wall bracket.
- Determine above finished floor dimension and add 2 for indirect configuration.
-
Utility Box Installation:
- Determine above finished floor dimension and add 3-3/4 for direct/indirect configuration.
- Determine the power location for the 2X4 utility box.
-
Power Cord Installation:
Complete wall power connections and attach the supplied power cord through the power cover. Attach cover to the utility box. -
Fixture Installation:
Hook fixture housing on top of wall bracket and gently rotate downwards while supporting housing. The housing should engage on all wall brackets and lock in position.
FAQ
-
What should I do if I encounter issues during installation?
If you encounter any issues during installation, refer to the detailed instructions provided or contact customer support for assistance. -
Can the TruGroove wall fixtures be connected to create longer runs?
Yes, the TruGroove 4ft, 6ft, and 8ft modules can be joined together to create continuous runs. Follow the instructions provided for connecting multiple fixtures. -
Are there any specific safety precautions to be aware of during installation?
Ensure all mount brackets are secured to wall structure and follow national and local building and electrical codes for safe installation. -
What is the recommended spacing for wall brackets?
Use 2 brackets for each 4ft module and 3 brackets for each 6ft and 8ft module. Wall brackets should be installed a maximum of 12 inches away from fixture ends.
System Overview
These instructions review how to install TruGroove wall fixtures. TruGroove
4ft, 6ft and 8ft modules can be installed as individual standalone units, or
they can be joined together to create continuous runs. Use these in-structions
in addition to supplied TruGroove suspended installation instructions.
IMPORTANT: Read all instructions including fixture/sensor wiring AND
mechanical details before beginning installation. All mount brackets must be
secured to wall structure (studs or cross-braces).
TruGroove Endcap Kit(s)
- TG D/I endcap (x1)
-
8-32 x 3/8” screws (x2)
- Cable strain relief (x1) (Heyco #7418)
- 1/2” Bushing (x1)
- 1/2” Plug (x1)
TruGroove Joint Kit(s)
- Joiner aligner (x2)
- Joiner biscuits (x2)
-
10-32 x 3/4” (x2)
-
10-32 hex lock nut (x2)
- 1/2” Plug (x2)
Module Lengths
TruGroove wall fixtures come in 4ft, 6ft and 8ft modules. Overall module lengths are shown below. Add 0.2” for each endcap for accurate run length.
Tools Required
See supplied suspended TruGroove installation instructions for tools re- quired.
Mount Spacing
TruGroove wall fixture modules are designed to attach to supplied wall brackets. Important: Use 2 brackets for each 4ft module and 3 brackets for each 6ft and 8ft module.
INSTALLATION INSTRUCTION
-
Arrange boxed fixture on floor in specified mounting location, remove fixtures from boxes.
-
Lens Removal
Remove lens from fixture and set aside until fixture installation is complete. Use cotton gloves to handle lenses and keep in a clean environment. -
Install Wall Bracket
Determine above finished floor dimension and add 2” for indirect configuration. Draw center line, level and center wall brackets. Install to structure using appropriate hardware (by others).
Install Wall Bracket
Determine above finished floor dimension and add 3-3/4” for direct/indirect
configuration. Draw center line, level and center wall brackets. Install to
structure using appropriate hardware (by others).
-
Utility Box Installation
Determine power location for 2”X4” utility box (by others). Prior to installation, ensure center of utility box is centered on wall bracket center line as shown. Recommended position of utility box is 6” to 8” away from fixture end. -
Power Cord Installation
Complete wall power connections and attach supplied power cord through power cover. Attach cover to utility box. -
Power Cord Installation
Determine power feed location on fixture. Attach supplied ½” bushing as shown. -
Power Cord Installation
Install supplied ½” plug at opposite end of fixture housing. -
Fixture Installation
Hook fixture housing on top of wall bracket and gently rotate downwards while supporting housing. Housing should engage on all wall brackets and lock in position. -
Power Cord Installation
Feed power cord through ½” bushing installed in step 6. Crimp supplied cable strain relief to secure power cord inside fixture housing. Use Heyco PN0019(R12) crimping tool to ensure proper installation. -
After module 1 is installed, adjust the tilt screw as required to level fixture.
-
Fixture Joining
- To join fixtures, follow attached TruGroove suspended installation instructions. For direct/indirect fixtures, refer to step 8 of supplied direct/indirect installation instructions.
- For indirect fixtures, refer to step 7 of supplied indirect installation instructions.
-
Endcap Attachment
- To attach endcaps, follow attached TruGroove suspended installation instructions. For direct/indirect fixtures, refer to step 13 of supplied direct/indirect installation instructions.
- For indirect fixtures, refer to step 16 of supplied indirect installation instructions.
-
Finishing
- Ensure all fixtures are level and in line with each other.
- If horizontal leveling is required, adjust tilt screw shown in step 10, level fixture and re-tighten screw.
- Check that all joint or endcap screws are installed and all seams are tight.
- Use spare 1/2” plug(s) provided to close any open 1/2” electrical knockout location(s) in top reflector.
- Lock wall bracket screws shown in step 10 to secure fixtures to wall brackets.
- Install lenses (if applicable).
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manu-al, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be re-quired to correct the interference at his own expense.
Sensor in Rows
-
Single Sensor Controlling Whole Row
Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures. Note :
A maximum of 8 drivers can be wired to 8 sensors; confirm fixture driver count with factory. -
Multiple Sensors Controlling Separates Zones in a Row
Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
Notes :- A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
- Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
Sensor Spacing
- For correct operation, sensor should be placed a minimum distance of 8ft apart.
- Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.
Important Consideration When Using Sensor in a Row
- For fixtures with wireless sensors (CS, SB or RA options): DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
- For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
- For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.
Occupancy Sensor Coverage
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.
Daylight Sensor
-
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:
- Minimum distance from the window ≥ 2ft (0.6m).
- Prevent light reflections from outside entering the sensor (for example sunlight re-flection on a car hood) as this will lead to incorrect light regulation.
-
As a guideline the formula 0.72 X H can be used to calculate the minimum distance be-tween the window and sensor whereby H is the height from the bottom of the window to the sensor.
-
The detection area for the movement sensor can be roughly divided into two parts;
- Minor movements (person moving ≤ 3ft/s or 0.9m/s).
- Major movements (person moving ≥ 3ft/s or 0.9m/s).
Photosensor spatial response
ABOUT COMPANY
- © 2019 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the coerright owner.
- Phone: 604.888.6811
- Web: ledalite.com/products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>