LEDALITE TM-11 TruGroove Surface Micro Instruction Manual

May 15, 2024
LEDALITE

LEDALITE TM-11 TruGroove Surface Micro

LEDALITE-TM-11-TruGroove-Surface-Micro-product

Specifications

  • Product Name: TruGroove Surface Micro
  • Module Lengths: 2.0ft, 2.5ft, 3.0ft, 3.5ft, 4.0ft, 5.0ft, 6.0ft, 8.0ft
  • Tools Required: Screwdriver (optional)

FAQ

  • Q: Where can I find the power label location?
  • A: For D/I symmetric and asymmetric fixtures, power labels can be found on light engine pans or under-end louvre modules. For Direct and Surface symmetric and asymmetric fixtures, power labels can be found on the upper pan.
  • Q: What are the dimensions for the Joiner Mounting for the Ceiling Bracket?
  • A: The A/C gripper is adjustable by 0.63 inches (16mm).

System Overview

These instructions review how to install TruGroove surface micro fixtures. Modules can be installed as individual 2ft, 2.5ft, 3ft, 3.5ft, 4ft, 5ft, 6ft or 8ft standalone units, or they can be joined together to create continuous runs.
IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation. All ceiling brackets must be secured to the ceiling structure (studs or cross-braces).
Power feed connections for TruGroove surface micro modules can be made through a recessed 2” X4” utility box (by others) or with a surface-mounted junction box/exposed conduit (by others).

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-1

Module Lengths

  • TruGroove surface micro fixtures come in the module lengths shown.
  • Add 0.25″ for each endcap for accurate run length.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-2

__

Length without endcaps

| feet| 2.0| 2.5| 3.0| 3.5| 4.0| 5.0| 6.0| 8.0
---|---|---|---|---|---|---|---|---|---
Inches| 24.0| 30.0| 36.0| 42.0| 48.0| 60.0| 72.0| 96.0
mm| 610| 762| 914| 1067| 1219| 1524| 1829| 2438

TOOLS REQUIRED

  • 2 Phillips screwdriver

  • Flat-head screwdriver
  • 2 Robertson screwdriver (optional)

  • small ratchet
  • Ø7/8 drill bit

ATTENTION: Install under local and national building and electric codes.

Surface Mount Installation Instructions

  • This equipment has been tested and found to comply with the limits for a Class A digital device, according to part 15 of the FCC Rules.
  • These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warning! Shock Hazard!

IMPORTANT
Disconnect or turn off power before attempting any installation, service or maintenance.

Warning! Shock Hazard!
The fixture must be connected to the building ground via the provided ground wire before re-connecting to a main power supply.

Power Label Location

  • For D/I symmetric and asymmetric fixtures, power labels can be found on light engine pans or under-end louvre modules.
  • For Direct and Surface symmetric and asymmetric fixtures, power labels can be found on an upper pan.

Joiner Mounting Dimensions for Ceiling Bracket

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-5

Installation Notes

  • Arrange boxed fixtures on the floor in specified mounting locations, based on supplied layout drawings. Remove fixtures from boxes.
  • Install all ceiling mounting components and vertical aircraft cables using separate installation instructions for Aircraft Cab le Mounting (supplied).

Lens Removal

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-6

Lens Removal: To remove the snap-in lens for maintenance purposes, insert a flat, smooth-edged object between the lens and housing (avoid screwdrivers). Twist to release pressure and remove the lens.
Note: The optional Drop Lens is shipped separately.

Symmetric Fixture

  • Remove the lens from the fixture and set aside until fixture installation is complete. Use cotton gloves to handle lenses and keep in a clean environment.
  • Remove the 2 screws securing the lower light engine and temporarily support the light engine in position below the fixture.
  • DO NOT ALLOW THE LIGHT ENGINE TO HANG FROM ELECTRICAL WIRES.
  • Save screws for re-installation later.

Asymmetric Fixture

  • Remove the lens and set it aside until fixture installation is complete. Use cotton gloves to handle lenses and keep in a clean environment.
  • Remove the 2 screws securing the lower light engine and temporarily support the light engine in position below the fixture.
  • DO NOT ALLOW THE LIGHT ENGINE TO HANG FROM ELECTRICAL WIRES.
  • Save screws for re-installation later.

Fixture with Louvers

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-9

Remove one louvre from the end of the fixture by pulling gently and temporarily suspending from available holes. The remaining louvers can be pushed to the centre for better access. Remove the screws securing the surface plate. For louver-lens combinations, remove both louvre and lens. Use cotton gloves to handle lenses and keep in a clean environment.
DO NOT ALLOW THE LIGHT ENGINE TO HANG FROM ELECTRICAL WIRES.

Ceiling Bracket Installation

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-10

Determine the location of ceiling brackets. Pull the aircraft cable through the bracket. Centre and install ceiling brackets to the structure (studs or cross-braces) using appropriate hardware (by others).

Recessed Utility Box

  • For a recessed 2” X4” utility box, align and centre with ceiling brackets, and install with a long edge parallel with fixture module length. Ensure the utility box is positioned 3”(centre to centre) away from the ceiling bracket.

Surface Junction Box

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-12

For a surface-mounted junction box, install a junction box as required. For a cleaner install and better alignment with installed fixture modules, centre junction box and conduit exit with the centre line of ceiling brackets. The junction box is required to be 3” (minimum) away from the mounting bracket.

Recessed Power Feed Location

Determine fixture power feed method and location. For a recessed utility box installation, break off power cover tabs using a flat screwdriver at the required end only. Power entry location is available only on one side on module lengths 2’,2.5’3’ and 3.5’.

Fixture suspension

  • Determine the location of ceiling brackets.
  • Use the table on page 1 for the exact dimensions. Centre and install ceiling brackets to the structure (studs or cross braces) using appropriate hardware (by others).

Fixture Installation

  • Insert aircraft cable into the gripper.
  • Repeat on the other end of the fixture.
  • Raise module 1 towards the ceiling, suspending both ends a few inches below ceiling level.

Recessed Power Connection

  • While supporting the module in the air complete power entry wiring connections. Ensure all connections are secure and all wires are neatly tucked inside the fixture wiring cavity.

Surface Power Feed Preparation

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-17

  • For surface junction box installation, power feed to the fixture module is done through the endcap. Use masking tape on all outside surfaces. Align with the centre mark as shown and drill a 7/8” diameter hole.

Surface Power Feed Connection

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-18

  • Prepare power feed by installing the conduit and the connectors (by others) to the drilled endcap. Refer to step 16 for power connections and endcap installation.

Fixture Joining

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-19

  • With module 2 on the ground, tap small joiner aligners inside the top chase. Ensure small joiner aligners are inserted more than halfway inside the fixture housing. Insert large joiner aligners inside the lower case as shown.

Surface Power Feed Connection

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-20

  • Suspend Module 2. Refer to step 7. With module 2 supported complete wiring connection using the provided quick wire connectors. Note: Do not fully raise modules at the moment .

Fixture Joining

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-21

  • Bring modules 1 and 2 together. Engage joiner aligners in module 2 with a housing of module 1.

Fixture Joining

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-22

  • Ensure all connections are secure and all wires are neatly tucked inside the fixture wiring cavity. Slide fixture modules together gently.

Fixture Joining

  • Secure fixture modules together using the two #10-32 machine screws and the two #10-32 nuts supplied. Tighten until joint seam is tight.
  • Note: Do not overtighten.

Fixture Installation

Raise the row of modules to the ceiling simultaneously. Tighten and join again if required. Now the whole row is secured. Push excess aircraft cable through the opening.
IMPORTANT: Do not trim aircraft cable.

Surface power feed

  • For surface-mounted junction box, connect conduit and required connectors (by others) to drilled endcap. Refer to 9a & 9b.

Endcap with Sensor

  • Before installing the endcap, slide the sensor towards the centre of the fixture to gain access. Proceed with endcap installation, step 18.

Drop Lens Endcap Installation

  • Place the drop lens endcap as shown over the emboss of the endcap and proceed with endcap Installation of the endcap, step 18.

Endcap Installation

  • Slide the endcap onto the end of the fixture module and secure from below using two #8-32 X 3/18” screws. Tighten screws until the endcap seam is tight. Note: Do not overtighten.

Corner, Bracket Installation

  • If a corner is required, it is recommended the corner module be installed first. The position of the brackets is critical for installation. Place as dimensioned above.

Closed Pattern Installation

  • If installing a square or rectangular closed pattern, it is recommended to install opposite U-shaped fixture/corner patterns first and complete the installation by bringing U-shaped sections together as shown.

Replace Light Engine

  • Reinstall the lower led pans with the screws provided. Ensure the direction of light is as shown on layout drawings.

Fixture Lens Installation

Install lenses removed in step 1.

Installation Tip: For easier installation, start at a housing end or a joint by placing the lens at an angle and squeezing in slightly from the other side to guide inside the housing.

Fixture Lens Installation

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-33

Once lens is positioned inside the housing, starting on one end or joint, push upwards gently and work outward to complete the run.
Note: Flush lens and drop lens are installed the same way. A flush lens is shown for reference.

Louver Installation

Reinstall surface plates with the screws provided and follow with louvres. Start on one end of the louvre pressing gently on side tabs.

IMPORTANT: For asymmetric louvre fixtures, orientate the arrows on the louvre pan to point at the label on the outside of the housing.

Corner Lens Installation

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-36

Installation Tip: For easier installation of corner lenses, start at the corner and work outward to complete the run. Follow step 22.

Corner Louver Installation

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-37

  • Reinstall the surface corner plates with the screws provided.

Corner Louver Installation

Install filler plate before installing louvres.

Tip: For easier installation, start by squeezing the filler plate in slightly from both sides and guiding inside the housing.

Corner Louver Installation

Installation Tip: For easier installation, start on one end of the louvre pressing gently on side tabs.

  • Ensure all fixtures are level and in line with each other.
  • Check that all joint or endcap screws are installed, and all seams are tight.
  • Install LED Pan.
  • Power fixtures on and check all modules light up.
  • Install lenses.

PRF/ PRA
Interact Pro Foundation/Advance Install & Setup *not for Enterprise or Signify Commissioned projects To configure a lighting system with Interact sensors or RF nodes;

  • Ensure the luminaires are installed and powered on.
  • Download the Interact Pro app from either Apple’s App Store (for iOS) or Google’s Play Store.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-40

  • Register by tapping Request Access on the login screen in the app.
  • Click or scan the QR codes below to view instructions for setup.

Interact Pro Foundation Quick Start Guide

Interact Pro Advanced Quick Start Guide

Interact Pro Documentation

Interact Pro Setup Video

Contact Us 1-800-555-0050

Sensors in Rows

Single Sensor Controlling Whole Row

Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
Note:

  • A maximum of 8 drivers can be wired to one sensor; confirm the fixture driver count with the factory.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-46

Multiple Sensors Controlling Separate Zones in a Row

Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
Notes:

  • A maximum of 8 drivers can be wired to one sensor; confirm the fixture driver count with the factory.
  • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-47

Sensor Spacing

  • For correct operation, sensors should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-48

Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
  • DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
  • Fixture mains wiring should not be connected to a circuit with an external on/off switch.
  • For the best aesthetic condition, place sensors at the ends of the row only so as not to break the continuous lens.
  • For better occupancy coverage in longer rows, sensors may be placed mid-run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, the remote sensor may be used, note the same wiring rules will apply.

Occupancy Sensor Coverage

Note: The longer dimension of the detection area (Y1, Y2) is parallel to the longer dimension of the luminaire.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-49

Daylight sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline, the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-50

The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (a person moving ≤3ft/s or 0.9m/s).
  • Major movement (a person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response

LEDALITE-TM-11-TruGroove-Surface-Micro-fig-51

ATTENTION: Install under local and national building and electric codes.

© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify.

CONTACT

Signify North America Corporation

  • 400 Crossing Blvd, Suite 600
  • Bridgewater, NJ 08807
  • Telephone: 855-486-2216

Signify Canada Ltd

All trademarks are owned by Signify Holding or their respective owners.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEDALITE User Manuals

Related Manuals