LEDALITE ID-23 Tru Groove Recessed Micro Instruction Manual

May 15, 2024
LEDALITE

Linear
ID-23 T-Grid
TruGroove Recessed Micro

ID-23 Tru Groove Recessed Micro

Installation Instructions
Standalone or Continuous Run in T-Grid Ceiling
These instructions review how to install TruGroove recessed micro fixtures in T-Grid ceilings. For continuous run lengths, Please refer to layout drawings supplied by Ledalite in conjunction with these installation instructions. The graphics below show the components required to install a run of TruGroove fixtures in T-Grid ceilings.
IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installationLEDALITE ID 23 Tru Groove
Recessed Micro - Fig i Hanger Kit(s)

  • Bracket (x4)
  • Screws (x8)

NOTE:
One kit required for each module.
Tools required: Phillips screwdriver, 5/16” nut driver.
ii Joint Kit(s)

  • Joiner Aligners (x2)
  • Joiner Brackets (x2)
  • Hex Bolts (x4)
  • Screw(s) ( x1 symmetric, x2 for asymmetric )
  • LED pan connectors (x1)
    NOTE: Image shown is a symmetric connector. Asymmetric has two pieces.

NOTE: One (1) kit required for each module joint in continuous runs
ATTENTION: Install in accordance with local and national building and electric codes.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Important Notes

Warning, Shock Hazard
Fixture must be connected to building ground via the provided ground wire before connecting to mains power supply.
** Disconnect or turn off power before attempting any installation, service or maintenance.
Prepare Fixtures**
Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings.
Remove fixtures from boxes.
Remove plastic from fixtures.
Match up each fixture and lens based on the spec tag and ID number labelled on each fixture box for the specified run.

Install Fixtures

  1. T-Grid Install main tees, 2.88” on center. For continuous row lengths, refer to supplied layout drawings. Add 1/4 “ to the overall housing length indicated on your layout drawings. Position and secure the cross tees.

  2. Install Mounting BracketsLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 1Important: Install T-Grid mounting brackets to requiredheight.

  3. Install Fixture Above T-Bar GridLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 2Install the first fixture (or Standalone Unit) from above the T-Bar Grid.
    ATTENTION: Install in accordance with local and national building and electric codes.

  4. Install Joiner AlignersLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 3In the joining fixtures install the joiner aligners in the trim extrusion just past the halfway point.
    Important: To insert aligners, tap gently with a hammer until middle dimple is fully inserted into the joiner channel. Be sure to engage the dimple as shown.

  5. Complete Wiring and Connect FixturesLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 4Install the joiner fixture into the T-Bar Grid from above. Complete wiring and slide the fixtures together.

  6. Open Slots for Joiner BracketsLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 5Snap off the safety cover on joiner brackets slots with a flat head screw driver. This only needs to be done one sides that require joining.

  7. Install Joiner BracketsLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 6Install supplied joiner brackets with 5/16” nut driver.

  8. Secure Fixture on the GridLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 7Secure the fixture to T-bar grid.
    For continuous runs, finish installing run first and then secure to the T-bar grid.

  9. Install Power DropLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 8Install power drop at desired location. At power location(s), remove factory installed wire cover. Feed power wires through.
    Complete all wiring connections using wire nuts supplied by others.
    9a Install CAT6 Cables for POE OptionLEDALITE ID 23 Tru Groove Recessed
Micro - Fixtures 9Install CAT6 cables and desired location.

  10. Install Wire Access CoverLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 10Install wire access cover to close the fixture.

  11. Install Seismic RestraintsLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 11Install seismic restraints according to local building code requirements.

  12. 12a LED Pan Joiner – SymmetricLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 12Mount the LED pan connector with the supplied screw in the joiner kit.
    Note: This step is not required for louvers.
    12b LED Pan Joiner – AsymmetricLEDALITE ID 23 Tru Groove Recessed Micro -
Fixtures 13Mount the LED Pan connector with the supplied screw in the joiner kit.
    There are two pieces for asymmetric fixtures.
    Note: This step is not required for louvers.

  13. Install Drop Lens EndcapLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 14Push up drop lens endcap flush to bottom of trim while hand tightening with supplied screws.(8-18 x 3/8 Pan)LEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 15

  14. Standalone Units: Lenses are supplied in 2’, 3’, 4’, 5’, 6’ or 8’ lengths.
    Continuous Runs: Lenses are pre-cut to a maximum of 8’ lengths and are specific to run lengths. Consult layout drawings for placement.
    Installed lenses are removed in step 1.
    Installation Tip: For easier installation, start at a housing end or a joint by placing lens at an angle and squeezing in slightly from the other side to guide inside housing.
    Once lens is positioned inside housing, starting on one end or joint, push upwards gently and work outward to complete the run.
    Snap in lens into fixture.
    Note: Flush lens and drop lens are installed the same way. Flush lens is shown for reference.

  15. Fixture Lens Installation

  16. LEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 16Fixture Lens InstallationLEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 17

PRF/PRA Interact Pro Foundation/Advance Install & Setup
*not for Enterp-ise or Sigrify Commissioned projects
To configure a lighting system with Interact sensors or RF nodes;

  • Ensure the luminaires are installed and powered on.
  • Download the Interact Pro app from either Apple’s App Store (for iOS) or Google’s Play Store.

LEDALITE ID 23 Tru Groove Recessed Micro - Fixtures 18

LEDALITE ID 23 Tru Groove Recessed Micro - QR Codehttps://play.google.com/store/apps/details?id=com.philips.li.c4m&hl=nl| LEDALITE ID 23 Tru Groove Recessed Micro - QR Code 1https://itunes.apple.com/nl/app/interact-pro/id1353793570?mt=8
---|---

  • Register by tapping Request access on the login screen in the app.
  • Click or scan the QR codes below to view instructions for setup.

https://sme.interact-lighting.com/web/help/prf-pra/2.3/quick- start/quickstart_foundation.html| https://sme.interact-lighting.com/web/help /prf-pra/2.3/quick-start/quickstart_advanced.html
---|---
https://sme.interact-lighting.com/web/help/prf-pra/2.3/quick- start/quickstart_foundation.html| https://www.youtube.com/playlist?list=PLik6Wr9jZkR6zuAbSDI4rRn8WpZ6M0aST

https://www.usa.lighting.philips.com/support/connect/contact-us

Sensors in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
    Note:
    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.LEDALITE ID 23 Tru Groove Recessed Micro - Sensors in
RowsMultiple Sensors Controlling Separate Zones in a Row

  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes:
    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
    • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).

LEDALITE ID 23 Tru Groove Recessed Micro - Sensors in Rows
1

Sensor Spacing

  • For correct operation, sensors should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

LEDALITE ID 23 Tru Groove Recessed Micro - Sensors in Rows
2 Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
    DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
    Fixture mains wiring should not be connected to a circuit with an external on/off switch.

  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.

  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same wiring rules will apply.

ATTENTION: Install in accordance with national and local building and electrical codes.

Occupancy Sensor Coverage:

Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.
LEDALITE ID 23 Tru Groove Recessed Micro - Occupancy Daylight sensor
The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor. The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (person moving ≤3ft/s or 0.9m/s).
  • Major movement (person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response
LEDALITE ID 23 Tru Groove Recessed Micro - Occupancy 2

© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

Signify North America Corporation
400 Crossing Blvd, Suite 600
Bridgewater, NJ 08807
Telephone: 855-486-2216
Signify Canada Ltd.
281 Hillmount Road.
Markham, ON, Canada L6C 283
Telephone: 800-668-9008
All trademarks are owned by Signify
Holding or their respective owners.
www.ledalite.com
www.signify.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEDALITE User Manuals

Related Manuals