System Overview

These instructions review how to install ModiFly suspended fixtures. ModiFly 2ft, 4ft, 5ft, 6ft, and 8ft modules can be installed as individual standalone units, or they can be joined together to create continuous runs. The graphic below shows the components required to install a typical run of ModiFly suspended fixtures.

IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation.

System Overview

TOOLS REQUIRED: Phillips screwdriver, Flat-head screwdriver, #2 Robertson screwdriver (optional)

Safety

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interreference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warning! Shock Hazard!

IMPORTANT:
Disconnect or turn off power before attempting any installation, service or maintenance.

Warning! Shock Hazard!

Fixture must be connected to building ground via the provided ground wire before re-connecting to mains power supply.

Installation Notes

Arrange boxed fixtures on floor in specified mounting locations, based on supplied layout drawings. Remove fixtures from boxes.
Install all ceiling mounting components and vertical aircraft cables using separate installation instruction for Aircraft Cable Mounting (supplied).

ATTENTION: Install in accordance with local and national building and electric codes.

Module Lengths and Standalone Mounting Points

ModiFly suspended systems come in 2ft, 4ft, 5ft, 6ft and 8ft modules. Standalone mounting points and overall module lengths are shown below.

Module Lengths

Continuous Run

For continuous runs the fixture is mounted from the continuous run joint supplied in the straight joint assembly.

Continuous runs with 8ft modules are designed to mount on grid.

Module Lengths

Fixture Length 2ft 4f 5ft 6f 8ft
CR mounting 25-5/16” 48-7/8” 60-9/16” 72-7/16” 96”

Installation Instructions

  1. Prepare fixtures/install ceiling mounting components

Arrange boxed fixtures on floor in specified mounting locations.
Remove fixtures from boxes. Install all ceiling mounting components and grippers using separate installation instructions for Mounting (supplied).
NOTE: If conditions are dusty/dirty, recommended practice is to leave fixtures in their plastic bags until ready to remove top cap for wiring.

  1. Remove Top Cap

Remove screws along top of fixture with a Phillips or Robertson screwdriver and remove the top cap with the help of a flat head screw driver.
Repeat this for all fixtures prior to mounting.

  1. Feed Wires into Fixture

Feed wires into the fixture on both ends of the fixture. Do this for all fixtures on joining ends.
Note: Not required for wires at the ends of the run.

  1. Mount Joints to Gripper

Insert aircraft cable through the joints and mount them in appropriate locations as supplied by layout drawing.
Mount the joints by feeding the aircraft cable through the gripper at the ceiling.

  1. Insert Aircraft Cable and Mount

Insert aircraft cable into diecast cross plate.
With two people, mount aircraft cable through the gripper as shown in previous step.
For standalone installation skip to step 8.

  1. Mount Fixture to Joint
    Installation Instructions
    Mount the fixture to the continuous run joint. Ensure continuous run joint is seated properly in the fixture. Secure with screw provided in joint kit with a Phillips screw driver.
    IMPORTANT: Do not over-tighten joiner screws. Ledalite recommends tightening by hand.

  2. Continuous Run
    Installation Instructions
    Feed wires from second fixture through the straight joint. Secure with screw provided in joint kit with a Phillips screw driver.
    Make power connections with supplied quick-wire connectors.
    IMPORTANT: Do not over-tighten joiner screws. Ledalite recommends tightening by hand.
    Repeat steps 6 and 7 for each additional fixture in row.

  3. Complete Electrical Connections

NON-POWER LOCATIONS: Cap all wires and tuck into wire cavity.
POWER LOCATIONS: Remove ½” knockouts as required.
Make power drop connection and tuck wires into fixture cavity.

  1. Close with Endcaps

Secure endcaps with screw provided with a Phillips screw driver.
IMPORTANT: Do not over-tighten joiner screws. Ledalite recommends tightening by hand.

  1. Secure Top Cap
    Installation Instructions
    Tuck wires into fixture then replace top caps and secure with screws provided with either a Robertson #2 screwdriver or a Phillips screwdriver.

  2. Leveling and Cleanup

  * Level row by adjustments at the gripper (see step 4).
  * Wipe light guide panel clean if required – ensuring to not introduce scratches.

Sensors in Rows

Single Sensor Controlling Whole Row

  1. Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures.
    Note:

    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
      Sensors in Rows
      Multiple Sensors Controlling Separate Zones in a Row
  2. Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
    Notes:

    • A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
    • Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
      Sensors in Rows

Sensor Spacing

  • For correct operation, sensors should be placed a minimum distance of 8ft apart.
  • Wireless sensors should be placed no further than 40ft apart for good wireless signal connection.

Sensor Spacing

Important Consideration When Using Sensors in a Row

  • For fixtures with wireless sensors (CS, SB or RA options):
    DO NOT connect fixture purple & brown (or purple & grey/pink) control wires to an external dimming switch.
    Fixture mains wiring should not be connected to a circuit with an external on/off switch.

  • For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.

  • For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensor may be used, note the same wiring rules will apply.

ATTENTION: Install in accordance with national and local building and electrical codes.

Occupancy Sensor Coverage:

Note: Longer dimension of detection area (Y1, Y2) is parallel to longer dimension of the luminaire.

Daylight sensor

The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:

  • Minimum distance from the window ≥2ft (0.6m).
  • Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.

As a guideline the formula 0.72 x H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.

The detection area for the movement sensor can be roughly divided into two parts:

  • Minor movement (person moving ≤3ft/s or 0.9m/s).
  • Major movement (person moving ≥3ft/s or 0.9m/s).

Photosensor spatial response

Support

2021 Signify Holding All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract, unless otherwise agreed by Signify.

Signify North America Corporation 400 Crossing Blvd, Suite 600 Bridgewater, NJ 08807
Telephone: 855-486-2216

Signify Canada Ltd. 281 Hillmount Road, Markham, ON, Canada L6C 2S3
Telephone: 800-668-9008

All trademarks are owned by Signify Holding or their respective owners.