| SnowLine 560 II ZLST551Q-12| SnowLine 620 E II ZLST651QE-230V| SnowLine 700
E STG1101QE-02| SnowLine 760 TE STG1376
---|---|---|---|---
| 112933| 112935| 112931| 112930
| Loncin LC165FS| Loncin LC170FDS| Loncin
LC185FDS| Loncin LC190FDS
| 182 cm3| 212 cm3| 375 cm3| 420 cm3
| 4,0 kW / 3600 min-1| 4,4 kW / 3600
min-1| 7,8 kW / 3600 min-1| 9,0 kW / 3600 min-1
| 132 x 56 x 112 cm| 132 x 62 x 112 cm|
134 x 70 x 115 cm| 134 x 76 x 115 cm
| 75 kg| 83 kg| 118 kg| 126 kg
| 560 mm| 620 mm| 700 mm| 760 mm
| 3,4 km/h +/-0,3| 3,4 km/h +/-0,3| 2,7
km/h +/-0,3| 3,0 km/h +/-0,3
| 1,8 km/h +/-0,3| 1,8 km/h +/-0,3| 1,8
km/h +/-0,3| 1,8 km/h +/-0,3
| ah = 4,05 m/s2 K = 1,5 m/s²| ah = 20,4
m/s2 K = 1,5 m/s²| ah = 5,885 m/s2 K = 1,5 m/s²| ah = 3,722 m/s2 K = 1,5 m/s²
| LpA = 86,6 dB(A) K = 3 dB(A)| LpA = 88,9
dB(A) K = 3 dB(A)| LpA = 86,8 dB(A) K = 3 dB(A)| LpA = 90,7 dB(A) K = 3 dB(A)
| LwA = 98 dB(A)| LwA = 102 dB(A)| LwA =
105 dB(A)| LwA = 106 dB(A)
| 33,02 cm / 13”| 33,02 cm / 13”| 38,1 cm
/ 15”| –
TRANSLATION OF ORIGINAL EC/EU DECLARATION OF CONFORMITY
We hereby declare, as the exclusively responsible party, that this product in its marketed form meets the requirements of the harmonised EU directives, EU safety standards and the product-specific standards.
Product
Snow blower, petrol-powered
Serial number
G4021012
Type
Snowline 560 II ZLST551Q-12
Snowline 620 E II ZLST651QE-230V
Snowline 700 E STG1101QE-02
Snowline 760 TE STG1376
Sound power level
EN ISO 3744
measured/guaranteed Snowline 560 II:
97 / 98 dB(A)
Snowline 620 E II:
100 / 102 dB(A)
Snowline 700 E:
105 / 107 dB(A)
Snowline 760 TE:
106 / 108 dB(A)
Manufacturer
AL-KO Geräte GmbH Ichenhauser Str. 14 D-89359 Kötz Germany
EU directives
2006/42/EC
2014/30/EU
2000/14/EC
Conformity evaluation
2000/14/EC Annex V
Duly authorised person for technical file
Andreas Hedrich
Ichenhauser Str. 14
D-89359 Kötz
Germany
Harmonised standards
ISO 8437:1989+A1:1997
EN ISO 12100:2010
EN ISO 14982:2009
EN 55012:2007+A1:2009
EN 61000-6-1:2007
Kötz, 08 May 2019
Peter Kaltenstadler Managing Director
COSTUMER SUPPORT
AL-KO GERÄTE GmbH | Head Quarter | Ichenhauser Str. 14 | 89359 Kötz |
Deutschland
Telefon: (+49)8221/203-0 | Telefax: (+49)8221/203-8199 | www.al-
ko.com
AL-KO Service: www.al-ko.com/service-contacts
References
- Startseite - AL-KO Unternehmensgruppe
- Servicestellen international | AL-KO Gardentech
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>