AL-KO SUB 6500 250W Electric Submersible Water Pump Instructions

October 27, 2023
AL-KO

SUB 6500 250W Electric Submersible Water Pump
Instructions
Garden + lobby
GLALITV FOR LIFE

SUB 6500 250W Electric Submersible Water Pump

SUB 6500 / DRAIN 7000 / 7500
Operating manualAL KO SUB 6500 250W Electric Submersible Water Pump -
SymbolAL KO SUB 6500 250W Electric
Submersible Water Pump - Figure 1

| SUB 6500 (Art.Nr. 112 820)| DRAIN 7000 (Art.Nr. 112 821)
DRAIN 7500 (Art.Nr. 112 822)
---|---|---
| 250 W| DRAIN 7000 350 W
DRAIN 7500 450 W
| 230 V AC/50 Hz| 230 V AC/50 Hz
| X 8| X 8
| 5 m| 5 m
| 6 m| DRAIN 7000 6 m
DRAIN 7500 6 m
| 6500 l/h| DRAIN 7000 7000 l/h
DRAIN 7500 7500 l/h
| 35 °C| 35 °C
| 8 cm| 13 cm
| 2 – 3 mm| 30 mm
| 4,0 kg| 4,4 kg
| 2,5 cm| 3 cm
| on: 38 cm
off: 17 cm| on: 41 cm
off: 20 cm
| 10 m| 10 m

ABOUT THIS HANDBOOK

  • Read this documentation before starting up the machine. This is a precondition for safe working and flawless operation.
  • Observe the safety warnings in this documentation and on the product.
  • This documentation is a permanent integral part of the product described and must be passed on to the new owner if the product is sold.

Explanation of symbols
CAUTION!
Following these safety warnings carefully can prevent personal injury and/or material damage.
**** Special instructions for greater ease of understanding and improved handling.

PRODUCT DESCRIPTION

This documentation describes various different models of immersion pumps. Identify your model using the identification plate.
Product overview

  1. Carrying handle
  2. Connection cable
  3. Float switch cable
  4. Pump housing
  5. Combination adapter
  6. Float switch
  7. Connection elbow
  8. Suction slots

Function
The immersion pump draws the conveying medium through the suction slots directly and feeds it to the pump outlet. It is switched on and off using a float switch.
Designated use
The immersion pump is designed for private use in the house and garden. It must only be operated within the framework of the deployment limitations in accordance with the technical data.
The immersion pump is suitable for:

  • Water removal in the event of a flood
  • Re-pumping and pumping out from vessels (e.g. swimming pools)
  • Water removal from streams and shafts
  • Water removal from drains and trickle shafts.
    ➯ only on DRAIN pump

The immersion pump is only suitable for conveying the following fluids:

  • Clear water, rainwater
  • Chlorine-containing water (e.g. swimming pools)
  • Waste water
  • Dirty water having a suspended matter proportion of max. 5 % and a grain size of max. 30 mm diameter.
    ➯ only on DRAIN pump

Any use not in accordance with this designated use shall be regarded as misuse.
Possible misuse
The immersion pump must not be used continuously. They are not suitable for conveying:

  • Drinking water
  • Salt water
  • Foodstuffs
  • Aggressive media, chemicals
  • Corrosive, flammable, explosive or fuming
  • Fluids fluids that are hotter than 35 °C
  • Water containing sand and abrasive fluids.
    ➯ only on Drain pump

SCOPE OF SUPPLY

Thermal protection
The equipment is fitted with a thermal protection switch which switches the motor off in the event of overheating. After a cooling-down phase of approx. 15 – 20 minutes the pump switches on automatically.
Operate the unit only if the immersion pump is fully immersed.

SAFETY INSTRUCTIONS

CAUTION!
Danger of injury!
Only use the machine and the extension cable if it is in perfect technical condition! Damaged units must not be used. Safety and protective devices must not be deactivated!

  • Children, or people who are not familiar with the operating instructions, are not allowed to use the machine.
  • Never lift, transport or suspend the unit using the connection cable.
  • Unilateral modifications or conversions of the unit are prohibited.

Electrical safety
CAUTION!
Danger when touching voltage conducting parts!
Disconnect the plug from the mains if the extension cable is damaged or severed! We recommend connecting a RCD (residual current operated device) having a nominal residual current of < 30 mA.

  • The house mains voltage must agree with the details quoted in the technical data, do not use any other supply voltage.
  • The unit must only be operated with an electrical installation in accordance with DIN/ VDE 0100, Part 737, 738 and 702 (swimming pools). Protection must be provided by a 10 A line protection switch and a RCCD (residual current operated device) having a nominal residual current of 10/30 mA.
  • Use only extension cables that are suitable for use outdoors – minimum cross-section 1.5 mm² . Cable drums should always be unrolled completely.
  • Damaged or brittle extension cables must not be used.
    ➯ Check the condition of your extension cable each time you start to use the equipment.

ASSEMBLY

Mounting the pressure line
see Fig. A

  1. Screw the connection elbow (7) into the pump outlet.
  2. Screw the combination nipple (5) into the connection elbow.
  3. Fix a hose to the combination nipple.

**** The combination nipple can be trimmed to suit the selected hose connection. Use the largest possible hose diameter.

STARTUP

Safety
CAUTION!
Exclude, by suitable means, that, in the event of a fault in the immersion pump, consequential damage is caused by flooding.

  • Make sure that the immersion pump is standing securely or operate the immersion pump suspended from a rope.
  • Make sure there is adequate clearance under the pump.
  • Never allow the immersion pump to run against a closed off pressure line.
  • When using in shafts, make sure the size is adequate.
  • Always cover the shaft with a secure footplate.

Switching the pump on
see Fig. A
CAUTION!
The immersion pump must not draw in any solid bodies. Sand and other abrasive materials in the conveying medium will destroy the immersion pump.

  1. Unwind the connection cable (2) completely.

  2. Make sure that the electrical plug connection is mounted in the area safe from flooding.

  3. Change the terminal position and adjust the switching points of the float switch (3) individually.

  4. Attach the cable on the float switch to the pump housing securely.
    ➯ Recommended cable length on the float switch approx. 120 mm
    Use a suitable plate to ensure secure mounting of the immersion pump on muddy, sandy or stony ground.

  5. Immerse the immersion pump in the conveying medium slowly. Hold the immersion pump at a slight angle to allow any air to escape.

  6. Insert the mains plug into the plug socket.
    ➯ The immersion pump switches on automatically using the float switch when a specific water level has been reached, and switches off again if the water drops below the switch-off height.

Switching the pump off

  1. Remove the mains plug from the plug socket.

Pumping out to residual water level
CAUTION!
Monitor the pump continuously when pumping out to the residual water level and avoid the pump running dry. Take the pump out of service when the residual water level is reached by pulling out the mains plug.
The float switch must be operated manually to pump to the residual water level:

  1. Remove the mains plug from the plug socket.
  2. Lay the float switch up and fix it in position.
  3. Insert the mains plug into the plug socket. The pump switches on and starts to feed.

**** If the water drops below the residual water level, (under 10/40 mm), the pump will draw air in. In this case, the pump must be vented when the water level rises and before using it again.

MAINTENANCE AND CARE

Cleaning the pump
**** After conveying chlorine-containing swimming pool water or fluids that leave a residue, the pump must be flushed out with clear water.

  1. Clean the suction slots on the suction foot if necessary with clear water.

STORAGE
** In the event of a risk of frost, the system must be drained completely.
DISPOSAL
Do not dispose of old equipment,batteries or accumulators as household waste!**
Product, packaging, and accessories were made with recyclable materials, and should be disposed of accordingly.

HELP IN CASE OF MALFUNCTIONS

CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the electrical system must be rectified by a qualified electrician.

Malfunction Possible cause Solution
Motor does not run Impeller blocked Remove dirt in the suction area.

Clean with a suitable tool through the opening at the back of the motor housing.
Thermal protection switch has switched off.| Wait until the thermal protection switch on the immersion pump switches on again. Take note of the maximum temperature of the conveying medium.
Have the immersion pump inspected.
No mains power.| Check the fuses, have the power supply checked by a qualified electrician.
Float switch does not switch off when the water level rises.| Send the immersion pump to an ALKO service facility.
Pump running but does not feed.| Air in pump housing.| Vent the immersion pump by holding it at an angle.
Blockage on the suction side.| Remove dirt in the suction area.
Pressure line closed off.| Open the pressure lone.
Pressure hose kinked.| Extend the pressure hose.
Feed rate too low| Hose diameter too small.| Use a bigger pressure hose.
Blockage on the suction side.| Remove dirt in the suction area.
Feed head to high.| Observe max. feed head, see technical data!

**** If the faults cannot be rectified, please contact our customer service department.

WARRANTY

If any material or manufacturing defects are found during the statutory customer protection period, we will either repair or replace the equipment, whichever we consider the more appropriate. This statutory period may vary according to the legislation in force in the country where the equipment was purchased.
Our warranty is valid only if:

  • The equipment has been used properly
  • The operating instructions have been followed
  • Genuine replacement parts have been used

The warranty is no longer valid if:

  • The equipment has been tampered with
  • Technical modifications have been made
  • The equipment was not used for its intended purpose

The following are not covered by warranty:

  • Paint damage due to normal wear
  • Wear parts identified by a border [xxx xxx (x)] on the spare parts list
  • Combustion motors (these are covered by a separate warranty from the manufacturer concerned)

The warranty period begins on the purchase by the first end user. Decisive is the date on the receipt. To make a claim under warranty, please take this statement of warranty and proof of purchase to the nearest authorised customer service centre. This warranty does not affect the usual statutory rights of the customer relative to the seller.

EU DECLARATION OF CONFORMITY

We hereby declare that this product, in the version brought into circulation by us, complies with the requirements of the harmonised EU guidelines, EU safety standards and the product-specific standards.

Product
Immersion pump, electrical
Serial number
G3023025| Type
SUB 6500
DRAIN 7000
DRAIN 7500| Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
D-89359 Kötz
---|---|---
Duly authorised person
Anton Eberle
Ichenhausen Str. 14
D-89359 Kötz
Kötz, 25.05.2012

Antonio De Filippo; Managing Director| EU guidelines
2006/95/EU
2004/108/EU
2000/14/EU (13)| Harmonised standards
EN 60335-1; VDE 0700-1:2007-02
EN 60335-2-41; VDE 0700-41:2004-12
EN 60335-2-41/A2; VDE 0700-41/A2:2009-02
EN 55014-1; VDE 0875-14-1:2007-06
EN 55014-1/A1; VDE 0875-14-1/A1:2008-12
EN 55014-2; VDE 0875-14-2:2009-06
EN 61000-3-2; VDE 0838-2:2006-10
EN 61000-3-2/A1; VDE 0838-2/A1:2007-05
EN 61000-3-2/A7; VDE0838-2/A7:2007-06
EN 61000-3-2/A4; VDE 0838-2/A4:2007-06
EN 61000-3-3; VDE 0838-3:2009-06

ETK SUB 6500
Art.-Nr. 112820AL KO SUB 6500 250W Electric Submersible Water Pump -
Figure 2

ETK DRAIN 7000
Art.-Nr. 112821
AL KO SUB 6500 250W Electric Submersible Water Pump -
Figure 3 ETK DRAIN 7500
Art.-Nr. 112822AL KO SUB 6500 250W Electric Submersible Water Pump -
Figure 4

Country Company Telephone Fax
A Al-KO Kober Ges m b H (+43)3578/2515227 (+43)3578/25 15 38
AUS AL-KO International PTY LTD (+61)3/9767-3700 (+61)3/9767-3799
Bl l Eurogarden NV (+32)16/805427 (+32)16/805425
BG Valerii S&M Group SJ (+359) 2 942 34 02 (+359) 2 942 34 10
CH AL-KO Kober AG (+41)56/4183150 (+41) 56/418 3160
CZ AL-KO Kober Sp0l.st.o (+420)382/210381 (+420)382/212782
DK AL-KO Gerate GmbH (+49)8221/203-0 (+49)8221/203-138
DK AL-KO Ginge A/S (+45)9882 1000 (+45)98825454
EST/LT/LV AL-KO Kober SIA (+371) 67409330 (+371) 67807018
F AL-KO S.A.S (+33)3/85-763540 (+33)3/85-763588
GB Rochford Garden Machinery Ltd (+44)1963/828050 (+44)1963/828052
H AU-KO KFT (+36)29/537050 (+36)29/537051
HR Brun.ko.-prom d.0.0 (+385)1 3096 567 (+385)1 3096 567
I AL-KO Kober GmbH / SRL (+39)039/93293 11 (+39)039/9329390
IN AGRO-COMMERCIAL (+91) 3322874206 (+91)3322874139
IQ Gulistan Com (+946) 750 450 80 64
IRL Cyril Johnston & Co. Ltd (+44) 2890813121 (+44)2890914220
LY ASHOFAN FOR AGRICULT ACC (+218)512660209 (+218)512660209
MA BADRA Sarl (+212)022447128 (+212)022447130
MK Techno Geneks (+389) 2 2551801 (+389) 2 2520175
N AL-KO GINGE A/S (+47)64862550 (+47)64862554
NL 0 OE LEEUW GROENTECHNIEK (+31)38/444 6160 (+31)38/444 6358
PL AL-KO Kober z.0.0 (+48)61/816 1925 (+48)61/8161980
RO OMNITECH Technology SL (+4) 021 326 36 72 (+4) 021 326 36 79
RUS 000 AL-KO Kober (+7)499/16887 18 (+7) 499/96600-00
RUS AL-KO St. Petersburg GmbH (+7)812/4461075 (+7)812/4461075
s AL-KO Ginge Svenska AB (+46)(0)31573580 (+46)(0)31575620
SK AL-KO Kober Slovakia Sp0ls.t.0 (+421)2/45994112 (+421)2/45648117
$LO DARKO OPARA SP (+386) 17225858 (+386)17225851
SRB Agromarket do0 (+381)34/30800 (+381)34/30816
TR ZIMAS AS (+90) 232 4580586 +90) 232 4572697
UA TOV AL-KO Kober (+380) 44/4923396 (+380)44/492 3397

AL-KO Geräte GmbH
Headquarter
Ichenhauser Strife 14
89359 Koetz
Germany
Telefon: (+49)8221/203-0
Telefax, (+49)8221/203-138
www.al-ko.com
© 2012 AL-KO KOBER GROUP Kötz, Germany
This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission of the AL-KO KOBER GROUP.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AL-KO User Manuals

Related Manuals