AL-KO RAIN 2500 Submersible Pressure Pump User Manual

June 17, 2024
AL-KO

QUALITY FOR LIFE
Garden + HobbyAL KO RAIN 2500 Submersible Pressure
Pump User Manual

RAIN 2500 Submersible Pressure Pump

AL KO RAIN 2500 Submersible Pressure Pump - SymbolsAL KO RAIN 2500 Submersible Pressure Pump -
Fig

| RAIN 2500
---|---
| 350 W
| 230-240 V~, 50 Hz
| X4
| max. 3 m
| 11 m
| 2500 l/h
| max. 35 °C
| 3/4″
| 4,6 kg

INTRODUCTION

Read these operating instructions carefully before putting the pump into operation.
Compliance with the operating instructions provided by the manufacturer is a prerequisite for safe and proper use of the pump.
Keep these operating instructions in a safe place and pass them on to any person who may be using the pump.
The following symbols are used:
ATTENTION!
This symbol indicates instructions that must be carefully observed to ensure the safety of the user and other persons.
WARNING
This symbol indicates instructions that must be observed to prevent damage to the pump.
NOTE
This symbol indicates any special technical requirements to be observed.

SAFETY NOTES

The pump may only be used in swimming pools, garden ponds and fountains when operated in conjunction with a residual-current device with a residual- current rating of 10/30 mA in accordance with DIN/VDE 0100, Parts 737, 738 and 702. Note that the power point must be protected by a 10 A fuse.
Observe the mains voltage: the information on the nameplate of the pump must be in agreement with the data for the mains power grid.
Extension cables must have a min. crosssection of 3 x 1.5 mm² and be compliant with type H07RN-F as per DIN 57282/57245; mains plug and extension connections must be protected from water splashes. Ensure that extension cables on drums are fully extended.
For safety reasons, the pump must not be operated by:
− persons unfamiliar with the operating instructions.
− children under the age of 16.
The pump may not be used for any other purpose than its designated use. Before using, make sure that:
− the pump, the power cable and the plug are not damaged.
− no persons are touching the water to be drawn off.
Before using, always subject the pump to a visual inspection: a pump which is damaged should not be used. In the event of damage, have the pump checked by AL-KO Service.
The mains power cable must not be used for fastening, lifting or transporting the pump. Do not interrupt the mains supply by unplugging at the power extension cable but rather disconnect at the outlet socket.
Disconnect the plug from the mains power supply before performing any work on the pump or if a fault is detected or occurs. Make sure that the plug is kept dry.
**** The pump may not be changed or modified. AL-KO is not liable for any damage caused if it is due to improper repair or if parts exchanged are not original parts or parts approved by AL-KO and if repairs were not carried out by an AL-KO Service Centre or an authorised specialist.

PROPER USE

Designated use
The pump is designed for use in private households. It may only be operated in applications as set out in the technical data sheet. The pump is exclusively designed for:
− drawing off water collected in rain water tanks and other water containers.
Improper use
The pump must not be used in continuous operation: it must be turned off as soon as there is no more water to be delivered. It should not be used for the delivery of:
− salt water
− waste water
− foodstuffs
− corrosive liquids or chemicals
− inflammable, explosive or volatile liquids
− sandy water or abrasives.
The max. permissible water temperature of 35 °C must not be exceeded.

FUNCTIONAL COMPONENTS

Pump (Fig. A, Fig. C)

  1. Shut-off valve

  2. Washer

  3. Cable attachment clip

  4. Flexible hose

  5. a Telescopic pipe, straight (∅ 20 mm)
    5b Telescopic pipe, straight (∅ 16 mm)

  6. Threaded pipe connection (G 3/4″)

  7. Mains power cable

  8. Carrying handle

  9. Pump

  10. Filter

Thermal protection
The pump comes with a built-in thermal overloadswitch that will switch the pump off if it overheats.After cooling down (ca. 15-20 min.), the pumpwill start again automatically. Do not allow thepump to dry-run: observe the min. water level.

PREPARATION PRIOR TO OPERATION

  1. Screw standpipe (5a) with the gasket (2c) on the connection thread (6).
  2. Screw standpipe (5b) with the gasket (2b) on the standpipe (5a).
  3. Screw flexible hose (4) with the gasket (2b) on the standpipe (5b).
  4. Screw stop-valve (1) with the gasket (2a) on the flexible hose (4).
  5. Attach connection cable (7) with the cable clip (3) according to picture B.
  6. Connect a hose with a standard quickrelease coupling to the shut-off valve (1).
  7. Place the pump into the water.

**** Ensure that the electrical connections for plugs and sockets are made in areas safe from flooding. A rope can be attached to the carrying handle for lowering the pump into deep containers or raising and fastening it.

PUTTING THE PUMP INTO OPERATION

  1. Plug in the mains connector of the pump into a power point. The pump will start to run immediately.
    Do not allow the pump to run longer than 15 minutes against a closed pressure side.

Switching off the pump

  1. Disconnect the pump’s mains plug after use.

MAINTENANCE AND CARE

** Disconnect the plug from the mains power supply before performing any work on the pump and ensure that it cannot be switched on inadvertently.
Cleaning the pump**

  1. After delivering chlorinated water from swimming pools or dirty rain water, the pump must be flushed with clear water after the filter (10) has been cleaned. See fig. C for removal and replacement of filter.

Frost protection
Protect the pump against frost. Store the pump dry if endangered by frost.

FAULT POSSIBLE REMEDY
Pump is running but does not deliver. Air cannot escape because the pressure
line is closed or kinked. Open the shut-off valve or check the hose for a

possible kink and straighten it
Suction foot/filter is blocked.| Clean the suction foot/filter.
Max. delivery height exceeded.| Reduce the delivery height.
Pump does not start or stops suddenly during operation.| Thermal switch has switched the pump off due to overheating.| Unplug the pump from the mains and clean the suction foot/filter. Wait until the pump switches on again automatically. Observe the max. water temperature.
No electrical power.| Check fuses and electrical connections.
Delivery output drops
suddenly.| Suction foot/filter is blocked.| Clean the suction foot/filter.

Translation of original user instructions
RAIN 2500
Art-Nr. 112 410AL KO RAIN 2500 Submersible Pressure Pump - Fig
1 EC declaration of conformity
We hereby declare that this product, in the form in which it is marketed, meets the requirements of the harmonised EU guidelines, EU safety standards, and the product-specific standards.
Product
Submersible pump, electric
Serial number
G3073075
Model
RAIN 2500
Manufacturer
AL-KO Geräte GmbH
Ichenhauser Str. 14
89359 KOETZ
DEUTSCHLAND
EU directives
2006/95/EG
2004/108/EG
Executive Officer
Anton Eberle
Ichenhauser Str. 14
89359 KOETZ
DEUTSCHLAND
Harmonised standards
EN 60335-1; VDE 0700-1:2007-02
EN 60335-2-41; VDE 0700-41:2004-12
EN 60335-2-41/A2; VDE 0700-41/A2:2009-02
EN 55014-1; VDE 0875-14-1:2007-06
EN 55014-1/A1; VDE 0875-14-1/A1:2008-12
EN 55014-2; VDE 0875-14-2:2009-06
EN 61000-3-2; VDE 0838-2:2006-10
EN 61000-3-2/A1; VDE 0838-2/A1:2007-05
EN 61000-3-2/A7; VDE0838-2/A7:2007-06
EN 61000-3-2/A4; VDE 0838-2/A4:2007-06
EN 61000-3-3; VDE 0838-3:2009-06
Kötz, 2010-07-14
Antonio De Filippo, Managing Director
Warranty
If any material or manufacturing defects are found during the statutory customer protection period, we will either repair or replace the equipment, whichever we consider the more appropriate. This statutory period may vary according to the legisla-tion in force in the country where the equipment was purchased.
Our warranty is valid only if:

  • The equipment has been used properly
  • The operating instructions have been followed
  • Genuine replacement parts have been used

The warranty is no longer valid if:

  • The equipment has been tampered with
  • Technical modifications have been made
  • The trimmer was not used for its intended purpose (for exa-mple, used for commercial or communal applications)

The following are not covered by warranty:

  • Paint damage due to normal wear
  • Wear parts identified by a border XXXXXX (X) on the spare parts list
  • Combustion motors – these are covered by a separate warranty from the manufacturer concerned

To make a claim under warranty, please take this statement of warranty and proof of purchase to the nearest authorised customer service centre. This warranty does not affect the usual statutory rights of the customer relative to the seller.

Country Company Telephone Fax
A AL-KO Kober Ges.m.b.H. (+43)35 78/2 51 52 27 (+43)3578/251538
AUS AL-KO International PTY. LTD (+61)3/9767-3700 (+61)3/9767-3799
B / L Eurogarden NV (+32)16/80 54 27 (+32)16/80 54 25
BG Valerii S&M Group SJ (+359) 2 942 34 02 (+359) 2 942 34 10
CH AL-KO Kober AG (+41)56/4183150 (+41)56/4183160
CZ AL-KO Kober Spol.sr.o. (+420)3 82 /21 03 81 (+420)382/212782
D AL-K0 Gerate GmbH (+49)8221/203-0 (+49)82 21/2 03-138
DK AL-KO Ginge A/S (+45)98 8210 00 (+45)98 82 54 54
EST/LT/LV AL-KO Kober SIA (+371) 67409330 (+371) 67807018
F AL-KO S.A.S. (+33)3/85-763540 (+33)3/85-763588
GB Rochford Garden Machinery Ltd. (+44)19 63/82 80 50 (+44)19 63/82 80 52
H AL-KO KFT (+36)29/5370 50 (+36)29/537051
HR Brun.ko.-prom d.o.o. (+385)1 3096 567 (+385)1 3096 567
I AL-KO Kober GmbH / SRL (+39)0 39/9 32 9311 (+39)0 39/9 32 93 90
IN AGRO-COMMERCIAL (+91) 3322874206 (+91)3322874139
10 Gulistan Corn (+946) 750 450 80 64
IRL Cyril Johnston & Co. Ltd. (+44) 2890813121 (+44)2890914220
LY ASHOFAN FOR AGRICULT. ACC. (+218)512660209 (+218)512660209
MA BADRA Sarl (+212)022447128 (+212)022447130
MK Techno Geneks (+389) 2 2551801 (+389) 2 2520175
N AL-K0 GINGE A/S (+47)64 8625 50 (+47)64 86 25 54
NL O.DE LEEUW GROENTECHNIEK (+31)38/444 6160 (+31)38/444 6358
PL AL-KO Kober z.o.o. (+48)61/81619 25 (+48)61/81619 80
RO OMNITECH Technology SRL (+4) 021 326 36 72 (+4) 021 326 36 79
RUS 000  AL-K0 Kober (+7)499/1688718 (+7) 499/96600-00
RUS AL-KO St. Petersburg GmbH (+7)812/4 4610 75 (+7)812/4461075
S AL-KO Ginge Svenska AB (+46)(0)3157 35 80 (+46)(0)31575620
SK AL-KO Kober Slovakia Spol.s.r.o. (+421)2/45994112 (+421)2/45648117
SLO DARKO OPARA S.P. (+386) 17225858 (+386)1 7 22 5 8 5 1
SRB Agromarket doo (+381)34/300765 (+381)34/354327
TR ZIMAS A.S. (+90) 232 4580586 (+90) 232 4572697
UA TOV AL-K0 Kober (+380)44/4 92 33 96 (+380)44/4 92 33 97

AL-KO Geraete GmbH l Head Quarter
Ichenhauser Str. 14
89359 Koetz l Deutschland
Telefon: (+49) 8221/203-0
Telefax: (+49) 8221/203 -138
 www.al-ko.com
https://manual-hub.com/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals