Fiilex V70 LED Viewing Lamp User Manual
- June 17, 2024
- Fiilex
Table of Contents
V70
LED
Viewing Lamp
User Manual
Parts Diagram
A Air Vents
B Lamp Cover
C Lens
D Flexible Arm
E Stand
F Touch Pad
G Base
H DC Plug
Package Contents
V70 LED Desk Lamp
Power Supply
Electrical Specifications
-
V70 LED Desk Lamp
Power Consumption 11-13 W Max
Input Voltage 24 VDC ± 5% -
Power Supply
Input 100-240 VAC 50-60 Hz
Output 24V, 1A max
Operation
- Insert the DC power plug into the lamp and the AC power plug into wall outlet.
- Tap the touch pad to turn V70 on.
- Tap the touch pad again to change color temperatures. V70 is programmed to cycle through 3000K, 4500K and 6000K mode with each tap.
- Hold the touch pad to adjust the intensity of any color temperature. V70 has three dimming steps then turns off for each color temperature. Tap the touch pad again to return the light to the High intensity setting.
Photometeric Specifications
High Intensity
Position | 3000K | 4500K | 6000K |
---|---|---|---|
Center | 1250 lux | 1385 lux | 955 lux |
3.5” | 1130 lux | 1285 lux | 885 lux |
10” | 780 lux | 980 lux | 700 lux |
Medium Intensity
Position | 3000K | 4500K | 6000K |
---|---|---|---|
Center | 950 lux | 830 lux | 665 lux |
3.5” | 860 lux | 770 lux | 600 lux |
10” | 465 lux | 430 lux | 345 lux |
Low Intensity
Position | 3000K | 4500K | 6000K |
---|---|---|---|
Center | 440 lux | 443 lux | 330 lux |
3.5” | 400 lux | 400 lux | 300 lux |
10” | 215 lux | 230 lux | 175 lux |
CRI values are ≥ 90
Safety and Maintenance
- The V70 desk lamp is designed for indoor use only.
- Do not attempt to disassemble the lamp body, as this may damage internal parts and cause electric shock.
- Check the AC main voltage before use (between 100-240 VAC at 47/ 63 Hz). Inappropriate voltage will cause damage to the electronic parts of the lamp and the power supply.
- Strong surrounding radio frequencies may interfere with the lamp’s touch function.
- Keep operation temperatures within 0°C ~ 40°C.
- Use a soft, dry towel to carefully clean the exterior of the lamp.
- Do not use coal oil or corrosive oil on lamp.
- Do not expose the product to high humidity.
- Keep air vents clear to avoid overheating the lamp.