BEA Eagle Artek Ceiling Accessory Installation Guide

June 16, 2024
BEA

EAGLE ARTEK
CEILING ACCESSORY

Eagle Artek Ceiling Accessory

BEA Eagle Artek Ceiling Accessory 1

DIMENSIONS

BEA Eagle Artek Ceiling AccessoryBEA Eagle
Artek Ceiling Accessory - DIMENSIONS

INSTALLATION

Place the mounting template in the desired mounting location and make the appropriate cuts.BEA Eagle Artek Ceiling Accessory - mounting template
1Route and connect the harness to the sensor, and then secure the sensor in the ceiling accessory.BEA Eagle Artek Ceiling
Accessory - mounting template 2Connect the EAGLE ARTEK harness to the ceiling accessory.BEA
Eagle Artek Ceiling Accessory - mounting template 3Secure the ceiling accessory to the ceiling using the provided screws and wingnuts.
BEA Eagle Artek Ceiling Accessory - mounting template
4Make the appropriate radar adjustments to create the desired field shape and position. Tilt angle should be 70° for optimal performance.BEA Eagle Artek Ceiling Accessory - mounting template
5Snap the Ceiling Accessory cover to the Ceiling Accessory housing.BEA Eagle Artek Ceiling Accessory - mounting
template 6

BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
Visit website for available languages of this document.https://www.qrfy.com/2gnGW__b5D

BEA Eagle Artek Ceiling Accessory - icon ©BEA | Original Instructions