SLV 1007232 M Pol S Lamp Head 180 Degree Instruction Manual

June 16, 2024
SLV

Instruction Manual INSTRUCTION MANUAL PART A
Luminaire head

1007232 M Pol S Lamp Head 180 Degree

1007232
1007234
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Technical Details are subject to change.

SLV UK
Unit E Chiltern Park
Boscombe Road, Bedfordshire
LU5 4LT

Operating Manual PART B
Luminaire head
1007232 …34
Read manual carefully and keep for further use!
Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not fasten anything on the product.
Do not cover the product.
Operate only with intact protection glass.
The supply cord may not be covered with soil.
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or a qualified electrician to avoid hazard.
Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Do not stare into the active light source.
Additional safety advices =

Use as directed

This product must only be used in connection with a light bollard with one of the following product numbers:1006379, 1006380, 1006381.
Safety class I (1) **** – Connection with protective conductor.
Do not strain mechanically or expose to strong dirt contamination.
IP65: Protection against dust (dust-tight) – Protection against jetted water from all directions.
Admissible ambient temperature(ta): -20°C …+35°C.

Light Source

The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
This product contains a light source of the energy efficiency class C.

Care / Storage

Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Do not clean with pressure washer.
Openings providing aeration or drainage must be kept free.
The following influences may have unwanted effects on the product: acidic surrounding, high salt content in the air, cleaning agents, fertilizer, thawing salt, chemicals.
Store dry and clean.

Installation

Follow local regulations for outdoor installations.
Do not seal the product yourself (e.g. with silicone).
Install according to declared IP type.
Install as shown in the figure.

Electrical connection

Protect the connection applying an IP 68 connection box or cable
connector (e.g. SLV 228730, 228726).
Suitable terminal block: 250V, 16A, Pole: 3
Live conductor → Conductor L
Neutral conductor → Conductor N
Protective conductor → Conductor ****(PE)
A maximum of 17 luminaires may be connected.

Check secure fixation and proper function!

© 0001 21.06.2023 SLV GmbH, Daimlerstr.
21-23, 52531
Übach-Palenberg, Germany,
Tel. +49 (0)2451 4833-0.
Made in China.