nVent LENTON LK1110STHD Interlok Position Transition Grout Fill Coupler Owner’s Manual

June 16, 2024
nVent LENTON

nVent LENTON LK1110STHD Interlok Position Transition Grout Fill Coupler

Product Information

The NVENT LENTON INTERLOK POSITION TRANSITION GROUT-FILL COUPLER is designed for splicing different diameter bars. It features a positional capability that allows the threaded coupler end to telescope out, closing a gap between forms and enabling alignment of the grout tubes. The coupler has an oversized cavity, providing greater field tolerance. The taper-threaded end helps prevent movement of the reinforcing bars and eliminates misalignment. Additionally, this coupler requires less grout compared to most competitive systems.

Product Usage Instructions

Pre-Installation
Before installing the NVENT LENTON INTERLOK POSITION TRANSITION GROUT-FILL COUPLER, please read and understand the detailed instructions and safety notices provided in the nVent LENTON Interlok Instruction Manual.

Installation Process

  1. Prepare the reinforcing bars by cleaning off any debris or rust.
  2. Insert one end of the reinforcing bar into the coupler body until it reaches the stop point.
  3. Rotate the coupler body to engage the taper-threaded end with the reinforcing bar.
  4. Tighten the coupler using an appropriate wrench until it reaches the specified torque.
  5. Repeat the process for the other reinforcing bar.

Grouting Process
After installing the couplers, follow these steps for the grouting process:

  1. Ensure that the gap between forms is properly aligned and closed.
  2. Insert grout tubes into the couplers through the oversize cavity.
  3. Pour grout into the tubes, ensuring that it fills the space completely.
  4. Allow the grout to cure as per the manufacturer’s instructions.

FAQ

Q: Are there different sizes available for the NVENT LENTON INTERLOK POSITION TRANSITION GROUT-FILL COUPLER?
A: Yes, coupler sizes not shown in the specifications may be available by special order. Please contact your nVent LENTON representative for more information.

Q: Can the NVENT LENTON INTERLOK POSITION TRANSITION GROUT-FILL COUPLER be used with different rebar sizes?
A: Yes, the coupler is designed to splice different diameter bars. Please refer to the specifications for the compatible rebar sizes.

Q: Does the NVENT LENTON INTERLOK POSITION TRANSITION GROUT-FILL COUPLER require a large amount of grout?
A: No, this coupler requires less grout compared to most competitive systems.

Q: Where can I find the nVent product instruction sheets and training materials?
A: Instruction sheets are available at www.nvent.com and from your nVent customer service representative.

Q: What happens if I do not follow the installation instructions and warnings provided by nVent?
A: Improper installation, misuse, misapplication, or failure to follow instructions and warnings may cause product malfunction, property damage, serious bodily injury, death, and/or void your warranty. Please ensure you carefully follow all provided instructions.

Q: How can I contact nVent customer service in different regions?
A: Here are the contact details for nVent customer service in different regions:

  • Europe Netherlands: +31 800-0200135
  • France: +33 800 901 793
  • Germany: 800 1890272
  • Other Countries: +31 13 5835404
  • APAC Shanghai: +86 21 2412 1618/19
  • Sydney: +61 2 9751 8500

Q: What are the brands under nVent’s powerful portfolio?
A: nVent’s powerful portfolio includes the following brands: CADDY, ERICO, HOFFMAN, RAYCHEM, SCHROFF, and TRACER. All trademarks mentioned belong to their respective owners. nVent reserves the right to change specifications without notice.

FEATURES

  • Designed to splice different diameter bars
  • Positional feature allows the threaded coupler end to telescope out to close a gap between forms and to allow alignment of the grout tubes
  • Over-sized cavity allows for greater field tolerance
  • Taper-threaded end helps prevent movement of the reinforcing bars and eliminate misalignment
  • Requires less grout than most competitive systems

SPECIFICATIONS

  • Material: Cast Iron
  • Finish: Plain
  • Packaging: Standard

Table 1/2

Catalog Number| Rebar Size, US| Rebar Size, Canada| Diameter 1 (Ø1)| Diameter 2 (Ø2)| Length 1 (L1)| Length 2 (L2)
LK1110STHD| #11, #10|  | 3.13″| 2.44″| 15.12″| 16.12″
LK1411STHD| #14, #11| 45M, 35M| 3.69″| 2.75″| 17.94″| 18.94″
Table 2/2

Catalog Number|

Length 3 (L3)

|

Bar Depth (BD)

| Coupler Body (CB)|

Unit Weight

| Packing Quantity
LK1110STHD| 9.88″| 1.58″| 12″| 10.1 lb| 1.0000
LK1411STHD| 12 3/4″| 1.68″| 15.19″| 19 lb| 1.0000

Designed to Meet:
AASHTO; ABNT NBR 8548:1984; ACI 318 Type 1 (125% Specified Yield); ACI 318 Type 2 (Specified Tensile); ACI 349; ACI 359; AS3600; BS EN 1992-1-1; CAN/CSA – N287.2/.3/.4; IBC Type 1 (125% Specified Yield); IBC Type 2 (Specified Tensile); US Army Corps of Engineers; CAN/CSA – A23.3

ADDITIONAL PRODUCT DETAILS

Bar dimensions and weights listed may vary by region. Coupler sizes not shown may be available by special order. Contact your nVent LENTON representative for more information. Prior to installation, please read and understand the detailed instructions and safety notices provided in the nVent LENTON Interlok Instruction Manual.

DIAGRAMS

WARNING
nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty.

North America

  • +1.800.753.9221
  • Option 1 – Customer Care
  • Option 2 – Technical Support

Europe

  • Netherlands: +31 800-0200135
  • France: +33 800 901 793

Europe

  • Germany: 800 1890272
  • Other Countries: +31 13 5835404

APAC

  • Shanghai: + 86 21 2412 1618/19
  • Sydney: +61 2 9751 8500
  • nVent.com

2024 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nVent LENTON User Manuals

Related Manuals