iPOWER 4 Inch 190 CFM Inline Duct Fan HVAC Exhaust Blower Air Circulation Vent Instructions
- June 16, 2024
- IPOWER
Table of Contents
- iPOWER 4 Inch 190 CFM Inline Duct Fan HVAC Exhaust Blower Air Circulation
- Product Information
- Product Usage Instructions
- Overview And Product Structure
- Dimensions
- Operating Parameters And Schematic wiring diagram
- Installation & Troubleshooting
- Repairs and Maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
iPOWER 4 Inch 190 CFM Inline Duct Fan HVAC Exhaust Blower Air Circulation
Vent
Product Information
Specifications
The iPower Inline Fan is composed of the following components:
- Chassis: Made of high-quality, cold-rolled steel with a plastic sealant for corrosion resistance. CAD optimizations on the flow channel design for maximum efficiency. Easy to install, repair, and clean. Available in sizes: 100mm, 125mm, 150mm, 160mm, 200mm, 250mm, 315mm.
- Impeller: Available in diameters of 190mm, 220mm, and 250mm. The curved-end blade impeller works in harmony with the fan casing to produce maximum air flow and efficiency while minimizing noise.
- External Rotor Motor: A single-phase asynchronous external rotor motor attached directly to the chassis. The impeller is driven directly by the rotor to minimize noise and provide high airflow. Extends service life.
- Junction Box: Made of flame-retardant ABS plastic for fireproof performance. External location allows for easy service and removal.
Product Structure
The iPower Inline Fan is composed of the following components:
- Chassis: Made of high-quality, cold-rolled steel with a plastic sealant for corrosion resistance. CAD optimizations on the flow channel design for maximum efficiency. Easy to install, repair, and clean. Available in sizes: 100mm, 125mm, 150mm, 160mm, 200mm, 250mm, 315mm.
- Impeller: Available in diameters of 190mm, 220mm, and 250mm. The curved-end blade impeller works in harmony with the fan casing to produce maximum air flow and efficiency while minimizing noise.
- External Rotor Motor: A single-phase asynchronous external rotor motor attached directly to the chassis. The impeller is driven directly by the rotor to minimize noise and provide high airflow. Extends service life.
- Junction Box: Made of flame-retardant ABS plastic for fireproof performance. External location allows for easy service and removal.
FAQ
- Q: Can the iPower Inline Fan be used outdoors?
- A: No, the iPower Inline Fan is designed for indoor use only.
- Q: How do I clean the fan?
- A: To clean the iPower Inline Fan, disconnect it from the power source and use a soft cloth or brush to remove any dust or debris from the fan blades and casing. Do not use water or liquid cleaners on the fan.
- Q: Can I install the fan in any orientation?
- A: The iPower Inline Fan can be installed in any orientation as long as both ends are properly connected to the pipeline.
Product Usage Instructions
Installation
To install the iPower Inline Fan:
- Ensure the fan is used indoors only.
- Mount the fan using non-adhesive materials.
- Keep the fan clean from dust and foreign contaminants.
- Connect both ends of the fan to the pipeline.
- For extended fan life, it is recommended to install air filters and one-way valves on the fan’s inlet and outlet.
Troubleshooting
If you experience any issues with the iPower Inline Fan, refer to the following troubleshooting tips:
- Check if the fan is properly connected to the power source.
- Ensure the fan is clean from any obstructions or debris.
- Inspect the wiring connections for any loose or damaged wires.
- If the issue persists, contact customer support for further assistance.
Repairs and Maintenance Notes
When performing repairs and maintenance on the iPower Inline Fan, please keep the following notes in mind:
- Ensure the fan is disconnected from the power source before starting any repairs or maintenance.
- Use appropriate tools and equipment for the specific repair or maintenance task.
- Follow all safety guidelines and instructions provided in the user manual.
- If unsure or inexperienced, it is recommended to seek professional assistance for complex repairs or maintenance tasks.
Warning
Read and understand the following warning before using the iPower Inline Fan:
- WARNING: To prevent electric shock or fire hazards, do not expose the fan to water or other liquids. Use the fan only as intended and follow all safety precautions.
Overview And Product Structure
Overview
The iPower Inline Fan, an addition to the iPower family, utilizes the newest and advanced technology to offer an affordable air movement solution. The iPower Inline Fan features high efficiency centrifugal impeller and a high performance external rotor motor. The compact, lightweight, and powerful motor generates high rate of air flow with minimal vibration and noise, which prolongs the inline fan’s service life. It’s versatile and compact design allows easy and flexible installation. Not just used in indoor gardens and greenhouses, the iPower inline fan can be found in hotels, halls, meeting rooms, supermarkets, railway stations, airports and other public areas that require positive ventilation.
Product Structure
- The iPower Inline Fan is composed of the chassis, impeller, external rotor motor, and junction box.
- Chassis: Is made of a high-quality, cold-rolled steel. The surface is treated with a plastic sealant to provide a strong resistance to corrosion. CAD optimizations on the flow channel design to allow the impeller perform at its greatest efficiency. Inlet and outlet diameter flanges are easy to install, repair and clean. Specifications: φ100mm, φ125mm, φ150mm, φ160mm, φ200mm, φ250mm, φ315mm.
- Impeller: diameter φ190mm, φ220mm, φ250mm. The curved-end blade impeller works with the fan casing in harmony; the fan can produce maximum air flow and efficiency while minimizing noise.
- External Rotor Motor: A single-phase asynchronous external rotor motor is located on the chassis. The impeller is attached directly to the rotor motor by die-casting. The impeller is driven directly by rotor to minimize noise while providing high airflow and extending service life.
- Junction box: The flame-retardant ABS plastic provides fireproof performance and is safe to use. The external location of the junction box allows for easy service and removal.
Dimensions
- A— Air outlet and inlet diameter
- B— Cylindrical chasse diameter of
- C— The length of a draft
- D— The total length of chasse
- E— Length of air inlet
Model | ΦA | ΦB | C | D | E | Specification(mm) |
---|---|---|---|---|---|---|
F4 | 95 | 268 | 22 | 200 | 22 | 190 |
F6 | 145 | 268 | 30 | 269 | 25 | 225 |
F8 | 195 | 342 | 30 | 269 | 50 | 250 |
F10 | 250 | 342 | 30 | 279 | 50 | 250 |
F12 | 300 | 400 | 30 | 295 | 50 | 280 |
Operating Parameters And Schematic wiring diagram
Operating Parameters
Model
| Voltage (V)| Frequency (Hz)| Input
Power (W)
| Air
velocity (CFM)
| Speed (rpm)| Noise (dB)| Insulation class| Weighet
(Kg)
| Static
(pa)
---|---|---|---|---|---|---|---|---|---
F4| ****
110
| ****
60
| 74| 190| 2460| 65| ****
F
| 3.1| 360
F6| 95| 442| 2380| 65| 5.6| 350
F8| 137| 745| 2600| 69| 6.6| 570
F10| 174| 862| 2390| 70| 6.6| 533
F12| 290| 1060| 2378| 71| 7.0| 704
Schematic wiring diagram
Installation & Troubleshooting
- Mount the fan on a stable platform via mounting brackets.
- Slide the mounting clamps over air duct
- Slide the air duct onto the flanges on the fan
- Tighten the clamps down with a flat-head screwdriver or a hex socket.
- Plug the 110V plug into a wall outlet to turn on the fan.
If the product had been in storage for more than six months, insulation resistance must be tested before use. Resistance to ground should be 20MΩ or more. Before starting the fan, use hands to drive impeller to insure smooth impeller rotation without obstruction. After connecting the power, observe the impeller rotation direction to be in the same direction with the nameplate. After confirming everything is functioning properly, leave it running for half an hour (30 minutes) to test the whether motor will have issues with overheating or undesirable noises. If the fan does not exhibit any signs of abnormal operations, it is safe to use and install.
To extend fan life, it is recommended that air filters and one-way valves be installed on the fan’s inlet and outlet. The circular fan must only be used indoors and be mounted with non-adhesive materials. Keep fan clean from dust and foreign contaminants. Both ends of the fan must be connected to the pipeline.
Repairs and Maintenance
Repairs and Maintenance Notes
Under normal operating conditions, the fan should be cleaned every six months. Clean any dirt that may have accumulated inside the chassis and dust on the impeller, etc. Do not use water or any other liquid cleaning agent; use only a clean brush or a clean dry cloth to wipe away any loose dirt or dust. Proper cleaning ensures the fan operates at maximum efficiency against the impact of dust without impacting air flow. If it is used in environments that contain heavy dust, cleaning should occur more often to prevent the accumulation of dust that would impact normal operations.
Disassembly of the fan is extremely convenient
- Remove the metal clamps from the flanges
- Remove the duct from the fan
- Dismount the fan from the mounting surface
- Remove the four screws that holds the fan housing
- Remove the junction box screw
- Remove 4 screws from the mounting bracket.
Warning
- Please read this manual carefully before installing.
- The fan’s motor power is multiplied by the shaft power factor of the specific operating conditions. In order to prevent electrical overload, please DO NOT obstruct the inlet or outlet airflow as the motor is running.
- Avoid impact or physical damage of the unit as it will cause premature failure.
- Keep fan in a dry environment.
- In the transmission of air, or any other non-corrosive medium, inlet temperature must not exceed 80C. The amount of dust and other solid contaminant should not exceed 100g per cubic meter. Avoid viscosity and fiber material.
- This product is covered under 12 month manufacturer’s warranty.