Dimension
The IQ3 is a Gateway device that ensures the communication between Nebula and
the SALTO Bulent devices providing the SVN (SALTO Virtual Network) features.
It is equipped with an Ethernet, WIFI (), Bluetooth and RS-485 interface. ()
Depending on the model.
Installation
EUROPE EUROPA
NORTH AMERICA
SWISS
CEILING/WALL INSTALLATION WITH HIDDEN CABLE
Remove!
CEILING/WALL INSTALLATION WITH EXPOSED CABLE
DESKTOP INSTALLATION
SEE WIRING DIAGRAM
Wiring
A. ETHERNET MODEL
B. ETHERNET + POE MODEL
C. ETHERNET + WIFI MODEL
*( )Not included**
ETHERNET MODEL
Plug
ETHERNET + POE MODEL
Plug
If there is no PoE infrastructure, use auxiliary power supply
Plug
ETHERNET + WIFI MODEL
Plug
If you do not connect to a WIFI network, connect the Ethernet cable.
Plug
COMMUNICATION WIRING DIAGRAM IN IQ3/SALTO Node
RS485 CONNECTION TO TERMINAL
RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.
RS485 CONNECTION WITH CABLE JACK
Product Overview
- Power (except PoE).
- Ethernet.
- RS485 (Jack cable).
- RS485.
Electrical Features
EXTERNAL POWER SUPPLY CHARACTERISTICS
| Min| Max| Typ
Input Voltage| 12-5%V| 12+5%V| 12V
Max Input Power| 15w| |
**Current Consumption***| | 200mA| 60mA
- Excluding RS485 Nodes.
Power supply must be calculated taking into account SALTO Nodes current consumption.
PoE
PoE Norms: IEEE 802.3af / IEEE 802.3at
PoE Class 0
OPERATING CONDITIONS
| Min| Max
Temperature| 0ºC| 60ºC
Humidity| 0| 95% (Non condensing)
WIFI CHARACTERISTICS
Frequency Range| 2400 MHz to 2483.5 MHz
Standard| IEEE 802.11b/g/n compliant
TX power| 16dBm
Range| 25-30m *
- Depending upon installed environment. To ensure correct operation, do not install the device near a metallic surface.
SALTO Bulent CHARACTERISTICS
Frequency Range: 2400 MHz to 2483.5 MHz
Standard| Bluetooth 5.2 Compliant
TX power| 8dBm
Indoor Range| 5-10m *
- Depending upon installed environment. To ensure correct operation, do not install the device near a metallic surface.
MAX. NUMBER OF DEVICES TO BE CONNECTED
SALTO Nodes: 6
Access points: 112
Configuration
- The device is configured using the Nebula App.
- Ethernet test: without any type of set up, the IQ3 is a DHCP ready device. If your network supports it, it is possible to check the Ethernet connectivity by pinging the address SALTO-IQ3-XXXXXX(XXXXXX corresponds to the final 6 digits of MAC).
Installation example
Maximum number of SALTO Nodes: 6
Maximum number of access points: 112
SALTO´ s Software
(*) Depending upon installed environment.
Signals
LED MODE | LED COLOUR | STATUS INDICATION |
---|---|---|
Blink long RED | ![Icon](https://manuals.plus/wp-content/uploads/2024/01 | |
/SALTO-IQ3.0-Gateway-Device-System-Installation-Guide-41.png) | **Device ex |
works. It will be doing advertising.
Blink short RED (3 seconds)| | I dentification signal when selected from a mobile phone.
The signal lasts 3 second.
Blink long BLUE| | Device
initialized with communication to the server.
Blink short YELLOW| | Device not communicating with the server.
Blink long GREEN| | Connection
established to a mobile phone.
Blink short GREEN| | Initialized and in programing mode. It is doing
advertising while waiting for a mobile connection.**
Operational test
- Check that the red light turns on.
- If you have connected to Ethernet, check that the lights on the RJ45 turn on.
All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any item in
this catalog, its design, construction, and/or materials.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>