JoJo 0.55kW SKD-2 Centrifugal Pump Range
Features & Benefits
- 1-year Quality Warranty
- NRCS approved
- Energy-efficient
- Easy to operate
- Automatic start/stop function
- Pre-wired with a 3-point plug
- Dry running protection
- Over-current protection
APPLICATIONS
Get the most out of your purchase!
- Add a JoJo Pump Cover to protect your pump from the elements and prolong its lifespan.
- Add a JoJo Pump-to-Tank Connector Kit for seamless connection from your pump to a JoJo water tank
1-year Quality Warranty
JoJo pumps purchased from an approved JoJo retail outlet and/or distributor carry a 1-year warranty from the date of purchase. In order to maintain your warranty, always ensure you install, operate and maintain the pump as per the instructions provided in this manual. Detailed T’s and C’s, as well as return policies and procedures are in the back of this manual.
Performance table
Pump specifications | 0.55kW | 0.75kW |
---|---|---|
Pump model | CPM146 | CPM158 |
Motor power | 0.55kW | 0.75kW |
Max. flow | 100 lt/min | 100 lt/min |
Max. pressure | 2.6 bar | 3.2 bar |
Max. fluid temperature | 40 ˚C | 40 ˚C |
Max. ambient temperature | 40 ˚C | 40 ˚C |
Max. suction lift | 7m | 7m |
Flow control switch | 0.55kW | 0.75kW |
--- | --- | --- |
Model | SKD-2 | SKD-2 |
Input voltage | 220V | 220V |
Frequency | 50 Hz | 50 Hz |
Current | 10 A | 10 A |
Max. power | 1500W | 2HP |
Protection | IP 44 | IP 44 |
Best efficiency range
Flow range | 0.55kW | 0.75kW |
---|---|---|
Lt/min | 30 to 80 lt | 40 to 80 lt |
Pressure range | 0.55kW | 0.75kW |
--- | --- | --- |
Bar | 1.6 to 2.3 bar | 1.9 to 2.8 bar |
Additional pump details
| 0.55kW| 0.75kW
---|---|---
Suction pipe (inches)| 1” x 1”| 1” x 1”
Start-up amps (single phase)| 14 A| 19 A
Running amps (single phase)| 4.2 A| 5.8 A
Weight| 12 kg| 16 kg
Dimensions:| |
Length| 340 mm| 340 mm
Width| 210 mm| 210 mm
Height| 265 mm| 265 mm
Construction characteristics | 0.55kW & 0.75kW |
---|---|
Pump body | Cast iron |
Impeller | Brass |
Motor shaft | Stainless steel 304 |
Mechanical seal | Ceramic-graphite |
PERFORMANCE CURVES
PUMP DIAGRAM
No.| Description| No.| Description| No.|
Description
---|---|---|---|---|---
1| O-Ring| 10| O-Ring| 19| Coupling
2| Brass air vent screw| 11| Cable fixer| 20| Foot
3| Impeller| 12| Water proof ring| 21| Cable protector
4| O-Ring| 13| Bearing| 22| Cable
5| Stator| 14| Wave spring| 23| Key
6| Motor bracket| 15| Fan cover| 24| Rotor
7| Terminal board| 16| Water vent screw| 25| End cover
8| Capacitor cover| 17| Pump body| 26| Fan
9| Capacitor| 18| Mechanical seal| |
Important information
- The pump must be earthed with no strain placed on the electrical cable.
- All maintenance should be carried out with the power supply disconnected.
- The pump is only designed for clean water use i.e. water containing no solid particles. Pumping muddy water or water containing suspended solids will severely reduce the life expectancy of the unit. Note: this type of application falls outside of the factory warranty.
- Extending the cable will affect your factory warranty. Always make use of an approved extending plug adapter.
- The pump should be installed in a ventilated, undercover area to protect the unit against direct sunlight, rain and spray from an irrigation system. A JoJo pump cover is recommended for best protection.
Recommended suction pipes: | Recommended discharge pipe: |
---|---|
HDPE (minimum 1” or 25mm) |
Copper, HDPE or any SABS approved piping (minimum ¾ inch or 22mm)
Helical coil reinforced flexible hose 1” or 25mm
INSTALLATION
The foundation should be solid enough to support the pump. It is recommended to secure the unit by bolting it to concrete or a paved surface. Before building the foundation, take the following into consideration:
- The placement of the pump incl. the direction of inlet/outlet.
- The height – ensure that the water level in the tank is higher than the suction side of the pump.
- Ensure the pump base is level so that the pump shaft is aligned horizontally.
- The pump suction line and fittings must all be on a horizontal plane.
- The discharge line and fittings must be on a vertical plane.
- The suction and discharge pipes should be supported independently by utilising pipe hangers and support blocks – this will prevent strain on the pump joints and casing.
- Before making a connection, always check the pipe alignment to ensure it is correct.
- The inlet and discharge pipe should align with the pump to ensure there are no bends or kinks that might affect the flow.
- The inlet and discharge pipe/connections must correspond with the design specifications of the pump as it may directly affect the efficiency and power consumption of the pump.
- The diameter of the suction and discharge pipe must be equal or greater than that of the ports of the pump.
- When being used as an alternative water supply for a home, install non-return valves to ensure no back pressure to the municipal supply or the pump.
PRIMING INSTRUCTIONS
IMPORTANT: the pump needs to be primed prior to use to ensure proper functionality and to prevent possible damage to any of the components.
- Ensure that the ball valve between the tank and pump is open.
- Open the air valve on the pump casing by removing the priming screw, to allow the air in the volute to escape and for it to be filled with water via gravity feed. The suction line and pump should slowly fill with water until a steady flow is visible from the air valve. Note: this also ensures that all air has been removed from the casing and suction piping.
- If after a few seconds water is not visible from the air valve, fill the pump volute manually until it is overflowing.
- Put the priming screw back in place and then tighten. Do not over tighten.
OPERATING INSTRUCTIONS
After priming the pump, do the following to test it and ensure proper operation:
- Check that the ball valve (a) between the tank and the pump is open and that the discharge val (ve b) on the pump is closed. Note: it is always advised to install a ball valve between pump and tank for maintenance purposes.
- Insert the plug into the main power supply and switch the plug on. The power indicator light of the flow controller must be illuminated.
- Open the discharge valve (b), the pump should start automatically.
- Close the discharge valve (b), the pump will switch off within 15 to 20 seconds (this is a built-in safety feature that protects the pump). This tests the pressure controller operation.
- Close the inlet valve (a) and open the discharge valve (b). The pump will switch on and run for 15 to 20 seconds. The pump should then stop operating and the failure light on the flow controller should be illuminated. This tests the run dry operation.
- Open the inlet valve (a) and press the reset button on the flow controller. The pump will start running. After completing steps one to six, the pump will be ready for use.
WARRANTY
JOJO PUMP WARRANTY
Please read this warranty in conjunction with the South African Consumer Protection Act 68 of 2008.
- JoJo warrants its pumps to the original end user/purchaser to be free of defective materials and workmanship under normal use for a period of 12-months from the date of purchase from authorised retailers and distributors. To be eligible for warranty repair or replacement, the pump must be returned to the point of purchase during and up to the expiry date of the warranty period. Proof of date of purchase is required.
- Liability in terms of this warranty shall be limited to repair or replacement of the pump. Liability for all and any other losses and/or subsequent damages suffered are expressly excluded.
- This warranty does not obligate JoJo to bear any cost of removal, installation, transportation, or other charges which may arise in connection with a warranty claim.
- The warranty shall not apply to repairs or service necessitated by normal wear and tear or for lack of reasonable and proper maintenance.
This warranty does not apply if in the sole judgement of JoJo the product or any of the components have been;
- (a) Tampered with, disassembled (unless as per JoJo’s specific instructions relevant to peripheral pumps and clearly displayed on fan cover), repaired or altered (except as may be pre-authorised by JoJo in writing);
- (b) Subjected to misapplication, misuse, neglect or accident; or
- (c) Used to pump anything for which the pump was not designed. Such use may compromise or harm the pump and/or any of its components.
IMPORTANT: this is the exclusive warranty given by us and no other warranty or guarantees, expressed or implied shall be of any force or effect. No distributor or other person is authorised to assume any liability or obligated for JoJo other than expressly provided herein.
RETURN POLICIES AND PROCEDURES
Refunds
Within 5 days of purchase; as part of the cooling off clause (section 16 of
the CPA), the pump may be returned for refund, provided that it is still
within the original packaging, unused, and in the original condition. Within
10 days of purchase; the pump may be returned for refund or replacement if it
does not meet the purpose for which intended (section 20 of the CPA), provided
that it is still within the original packaging, unused, and in the original
condition. In such instance the pump will be returned to JoJo for an
evaluation, after which an inspection report will be provided confirming
whether it meets the necessary requirements for refund or replacement.
Returns/repairs
Within 12 months; should the pump not operate as specified, or cease to do so within 12 months after being purchased, the return procedure is as follows:
- Return the pump to the store from which purchased, together with the proof of purchase (to confirm that it is within the 12-month warranty period). Please ensure that the condition of the pump is as specified in section four of this warranty, and that it is still packed in the original packaging.
- The store will send the pump to the nearest JoJo factory for an evaluation.
- At JoJo’s election, (a) the pump will either be repaired (if repairable) which repairs shall be and warranted for three months, or the balance of the 12-month period, whichever period is longer; or (b) the pump will be exchanged (t his only applies if the pump is non-repairable, and a replacement pump in similar visual condition will be provided by JoJo).
- The evaluation (once the pump is sent back to JoJo), repair/exchange and delivery to the store will take place within 14 days.
Our return/repair request form is available on our website at www.jojo.co.za.
Thank you for choosing JoJo. If there is anything that you are unsure about or need assistance with, please do not hesitate to contact us.
- www.jojo.co.za |