JoJo 0.6kW Self Priming Jet Pump Instructions

October 30, 2023
JoJo

0.6kW Self-priming Jet Pump
Instructions for use

Features & Benefits

1-year Quality Warranty Easy to operate Dry running protection
NRCS approved Automatic start/stop function Over-current protection
Energy-efficient Pre-wired with a 3-point plug

APPLICATIONS

JoJo 0 6kW Self Priming Jet Pump - APPLICATIONS

Get the most out of your purchase!

  • Add a JoJo Pump Cover to protect your pump from the elements and prolong its lifespan.
  • Add a JoJo Pump-to-Tank Connector Kit for seamless connection from your pump to a JoJo water tank

1-year Quality Warranty
JoJo pumps purchased from an approved JoJo retail outlet and/or distributor carry a 1-year warranty from the date of purchase. In order to maintain your warranty, always ensure you install, operate and maintain the pump as per the instructions provided in this manual.

Detailed T’s and C’s, as well as return policies and procedures are in the back of this manual.
Performance table

Pump specifications|
---|---
Pump model| JSPM600
Motor power| 0.6kW
Max. flow| 40 lt/min
Max. pressure| 3.6 bar
Max. fluid temperature| 40 ˚C
Max. ambient temperature| 40 ˚C
Max. suction lift| 7m
Flow control switch|
---|---
Model| SKD-2
Input voltage| 220V
Frequency| 50 Hz
Current| 10:00 AM
Max. power| 1500W | 2HP
Protection| IP 44

Best efficiency range

Flow range|
---|---
Lt/min| 10 to 30 l
Pressure range|
---|---
Bar| 2 to 3 bar

PERFORMANCE CURVE

JoJo 0 6kW Self Priming Jet Pump - CURVE

Additional pump details

Suction pipe (inches) 1” x 1”
Start-up amps (single phase) 8.5 A
Running amps (single phase) 2.7 A
Weight 13 kg
Dimensions:
Length 438 mm
Width 196 mm
Height 235 mm

JoJo 0 6kW Self Priming Jet Pump - pump

Construction characteristics|
---|---
Pump body| Polypropylene
Impeller| Noryl
Motor shaft| Stainless steel 304
Mechanical seal| Ceramic-graphite

PUMP DIAGRAM

JoJo 0 6kW Self Priming Jet Pump - PUMP DIAGRAM

No.| Description| No.| Description| No.| Description| No.| Description
---|---|---|---|---|---|---|---
1| Pump body| 10| Capacitor| 19| Air vent screw| 28| Stator
2| Air vent screw| 11| Capacitor cover| 20| O-Ring| 29| Foot
3| Nozzle| 12| O-Ring| 21| O-Ring| 30| Cable
4| Venturi| 13| Cable fixer| 22| O-Ring| 31| Key
5| Impeller| 14| Cable protector| 23| O-Ring| 32| Bearing
6| O-Ring| 15| Rotor| 24| Guide vane| 33| Wave spring
7| Coupling| 16| End cover| 25| Mechanical seal| 34| Fan
8| Motor bracket| 17| Fan cover| 26| Pump cover| |
9| Terminal board| 18| Water vent screw| 27| Water proof ring| |

Important information

  • The pump must be earthed with no strain placed on the electrical cable.

  • All maintenance should be carried out with the power supply disconnected.

  • The pump is only designed for clean water use i.e. water containing no solid particles. Pumping muddy water or water containing suspended solids will severely reduce the life expectancy of the unit.
    Note: this type of application falls outside of the factory warranty.

  • Extending the cable will affect your factory warranty. Always make use of an approved extending plug adapter.

  • The pump should be installed in a ventilated, undercover area to protect the unit against direct sunlight, rain and spray from an irrigation system. A JoJo pump cover is recommended for best protection.

Recommended suction pipes: Recommended discharge pipe:
HDPE (minimum 1” or 25mm) Copper, HDPE or any SABS approved piping (minimum ¾

inch or 22mm)
Helical coil reinforced flexible hose 1” or 25mm

INSTALLATION

Foundation

The foundation should be solid enough to support the pump. It is recommended to secure the unit by bolting it to concrete or a paved surface.
Before building the foundation, take the following into consideration:

  • The placement of the pump incl. the direction of inlet/outlet.
  • The height – ensure that the water level in the tank is higher than the suction side of the pump.

** Mounting**

  • Ensure the pump base is level so that the pump shaft is aligned horizontally.
  • The pump suction line and fittings must all be on a horizontal plane.
  • The discharge line and fittings must be on a vertical plane.

Piping

  • The suction and discharge pipes should be supported independently by utilising pipe hangers and support blocks – this will prevent strain on the pump joints and casing.
  • Before making a connection, always check the pipe alignment to ensure it is correct.
  • The inlet and discharge pipe should align with the pump to ensure there are no bends or kinks that might affect the flow.
  • The inlet and discharge pipe/connections must correspond with the design specifications of the pump as it may directly affect the efficiency and power consumption of the pump.
  • The diameter of the suction and discharge pipe must be equal or greater than that of the ports of the pump.
  • When being used as an alternative water supply for a home, install non-return valves to ensure no back pressure to the municipal supply or the pump.

OPERATING INSTRUCTIONS

It is advised to do the following to test the pump and ensure proper operation:

JoJo 0 6kW Self Priming Jet Pump - OPERATING

  1. Check that the ball valve (a) between the tank and the pump is open and that the discharge valve (b) on the pump is closed. Note: it is always advised to install a ball valve between pump and tank for maintenance purposes.
  2. Insert the plug into the main power supply and switch the plug on. The power indicator light of the flow controller must be illuminated.
  3. Open the discharge valve (b), the pump should start automatically.
  4. Close the discharge valve (b), the pump will switch off within 15 to 20 seconds (this is a built-in safety feature that protects the pump). This tests the pressure controller operation.
  5. Close the inlet valve (a) and open the discharge valve (b). The pump will switch on and run for 15 to 20 seconds. The pump should then stop operating and the failure light on the flow controller should be illuminated. This tests the run dry operation.JoJo 0 6kW Self Priming Jet Pump - OPERATING 2
  6. pen the inlet valve (a) and press the reset button on the flow controller. The pump will start running. After completing steps one to six, the pump will be ready for use.

JOJO PUMP WARRANTY

Please read this warranty in conjunction with the South African Consumer Protection Act 68 of 2008.

  1. JoJo warrants its pumps to the original end user/purchaser to be free of defective materials and workmanship under normal use for a period of 12-months from the date of purchase from authorised retailers and distributors.
    To be eligible for warranty repair or replacement, the pump must be returned to the point of purchase during and up to the expiry date of the warranty period. Proof of date of purchase is required.

  2. Liability in terms of this warranty shall be limited to repair or replacement of the pump. Liability for all and any other losses and/or subsequent damages suffered are expressly excluded.

  3. This warranty does not obligate JoJo to bear any cost of removal, installation, transportation, or other charges which may arise in connection with a warranty claim.

  4. The warranty shall not apply to repairs or service necessitated by normal wear and tear or for lack of reasonable and proper maintenance.

This warranty does not apply if in the sole judgement of JoJo the product or any of the components have been;
(a) Tampered with, disassembled (unless as per JoJo’s specific instructions relevant to peripheral pumps and clearly displayed on fan cover), repaired or altered (except as may be pre-authorised by JoJo in writing);
(b) Subjected to misapplication, misuse, neglect or accident; or
(c) Used to pump anything for which the pump was not designed. Such use may compromise or harm the pump and/or any of its components.

IMPORTANT: this is the exclusive warranty given by us and no other warranty or guarantees, expressed or implied shall be of any force or effect. No distributor or other person is authorised to assume any liability or obligated for JoJo other than expressly provided herein.

RETURN POLICIES AND PROCEDURES

Refunds
Within 5 days of purchase; as part of the cooling off clause (section 16 of the CPA), the pump may be returned for refund, provided that it is still within the original packaging, unused, and in the original condition.
Within 10 days of purchase; the pump may be returned for refund or replacement if it does not meet the purpose for which intended (section 20 of the CPA), provided that it is still within the original packaging, unused, and in the original condition. In such instance the pump will be returned to JoJo for an evaluation, after which an inspection report will be provided confirming whether it meets the necessary requirements for refund or replacement.
Returns/repairs
Within 12 months; should the pump not operate as specified, or cease to do so within 12 months after being purchased, the return procedure is as follows:

  • Return the pump to the store from which purchased, together with the proof of purchase (to confirm that it is within the 12-month warranty period). Please ensure that the condition of the pump is as specified in section four of this warranty, and that it is still packed in the original packaging.
  • The store will send the pump to the nearest JoJo factory for an evaluation.
  • At JoJo’s election, (a) the pump will either be repaired (if repairable) which repairs shall be and warranted for three months, or the balance of the 12-month period, whichever period is longer; or (b) the pump will be exchanged (this only applies if the pump is non-repairable, and a replacement pump in similar visual condition will be provided by JoJo).
  • The evaluation (once the pump is sent back to JoJo), repair/exchange and delivery to the store will take place within 14 days.

Our return/repair request form is available on our website at www.jojo.co.za.
Get the most out of your purchase!

| • Extends the lifespan of your Booster Pump
• Reduces noise
• UV-resistant
• Corrosion-resistant
• Available in our water tank colours| JoJo 0 6kW Self Priming Jet Pump -
PUMP COVER 2
---|---|---
| • Easy to use
• DIY-friendly
• All accessories included
• Great quality
• Suitable for use with our 0.37, 0.55, 0.6 and 0.75kW Booster Pumps| JoJo 0
6kW Self Priming Jet Pump - CONNECTOR KIT 21
---|---|---

JoJo 0 6kW Self Priming Jet Pump

Thank you for choosing JoJo. If there is anything that you are unsure about or need assistance with, please do not hesitate to contact us.

www.jojo.co.za
+27 11 695 8300
November 2022

Documents / Resources

| JoJo 0.6kW Self Priming Jet Pump [pdf] Instructions
0.6kW Self Priming Jet Pump, 0.6kW, Self Priming Jet Pump, Priming Jet Pump, Jet Pump, Pump
---|---
| JoJo 0.6kW Self Priming Jet Pump [pdf] Instruction Manual
0.6kW, 0.6kW Self Priming Jet Pump, Self Priming Jet Pump, Priming Jet Pump, Jet Pump, Pump
| JoJo 0.6kW Self Priming Jet Pump [pdf] Instruction Manual
0.6kW, 0.6kW Self Priming Jet Pump, 0.6kW Priming Jet Pump, Self Priming Jet Pump, Priming Jet Pump, Self Jet Pump, Jet Pump, Pump

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals