TEKBOX TBPCP1-20100 RF Pulse Current Monitoring Probe Owner’s Manual

June 9, 2024
TEKBOX

V1.0
TBPCP1-20100
RF PULSE CURRENT MONITORING PROBE

Introduction

The TBPCP1-20100 is a RF pulse current monitoring probe, expanding the Tekbox product range of affordable test equipment.
The probe has a very flat response from 20 Hz to 100 MHz and is characterized over the frequency range from 1 Hz to 200 MHz. The TBPCP1-20100 is typically used for surge or RF pulse current monitoring applications in the time domain, in contrary to RF current monitoring probes designed for EMC applications, which are typically used for measurements in the frequency domain.

TEKBOX logo

The aperture of the RF current monitoring probe is 25 mm. Its transfer impedance is -20 dB Ohm with a typical 3dB bandwidth from 20 Hz to 100 MHz.

Specification

Characterized frequency range: 1 Hz to 200 MHz
3 dB bandwidth: 20 Hz to 100 MHz (measured in a 50 + 50 Ohm loop)
Transfer impedance into 50 Ohm load: -20 dB Ohm; 0.1 V/A
Transfer impedance into high Z: 0.2 V/A
Probe port impedance: 50 Ohm
Droop rate: < 10% / ms
Rise time: < 5 ns
Max. CW primary RMS AC current with respect to internal resistor dissipation ratings: 300A
Max. primary single pulse current with respect to internal resistor pulse current ratings: 900A@ 100ms pulse width; 3000A @ 1ms pulse width Max. current time product: 0.04 Ampere seconds
Max. RMS AC current, linear: 22 A
Max. core temperature: 80 °C
Aperture diameter: 25 mm
Outside diameter: 76 mm
Height: 31 mm
Weight: 320 g
Connector type: N female

Transfer impedance

TEKBOX TBPCP1 20100 RF Pulse Current Monitoring Probe -
fig

Typical transfer impedance table

The table below shows typical transfer impedance data of a TBPCP1-20100 pulse current probe. Each current probe is delivered with its corresponding measurement protocol. The transimpedance is given for a 50 Ohm load.
Transimpedance [V/A] = 10^(dBOhm/20) @ 50 Ohm
Transimpedance [V/A] = 2*10^(dBOhm/20) @ High Z

Frequency| transfer impedance [dBΩ] 50 Ohm load| transfer impedance [V/A] 50 Ohm load| transfer impedance [V/A] high Z load
---|---|---|---
1 Hz| -43,49| 0,007| 0,013
2,5 Hz| -35,00| 0,018| 0,036
5 Hz| -28,96| 0,036| 0,071
7.5 Hz| -25,98| 0,050| 0,101
10 Hz| -24,27| 0,061| 0,122
12.5 Hz| -23,23| 0,069| 0,138
15 Hz| -22,41| 0,076| 0,151
17.5 Hz| -21,89| 0,080| 0,161
20 Hz| -21,49| 0,084| 0,168
25 Hz| -21,03| 0,089| 0,178
50 Hz| -20,29| 0,097| 0,194
75 Hz| -20,11| 0,099| 0,198
100 Hz| -20,08| 0,099| 0,198
1 kHz| -20,06| 0,099| 0,199
10 kHz| -20,02| 0,100| 0,200
100 kHz| -20,01| 0,100| 0,200
1 MHz| -20,01| 0,100| 0,200
10 MHz| -19,99| 0,100| 0,200
25 MHz| -19,99| 0,100| 0,200
50 MHz| -20,01| 0,100| 0,200
60 MHz| -20,16| 0,098| 0,196
70 MHz| -20,29| 0,097| 0,194
80 MHz| -20,30| 0,097| 0,193
90 MHz| -20,06| 0,099| 0,199
100 MHz| -19,54| 0,105| 0,211
110 MHz| -18,39| 0,120| 0,241
120 MHz| -17,46| 0,134| 0,268
130 MHz| -17,13| 0,139| 0,278
140 MHz| -17,21| 0,138| 0,276
150 MHz| -17,49| 0,133| 0,267
160 MHz| -17,75| 0,130| 0,259
170 MHz| -18,17| 0,123| 0,247
180 MHz| -18,80| 0,115| 0,230
190 MHz| -19,37| 0,108| 0,215
200 MHz| -19,87| 0,101| 0,203

Table1: Transfer impedance: 1 Hz to 200 MHz, typical data

Accessory

Tekbox supplies a calibrator suitable for the TBPCP1-20100 current probe:TEKBOX TBPCP1 20100 RF Pulse Current Monitoring Probe - fig
1

Ordering Information

Part Number Description
TBPCP1-20100 Pulse Current Probe 20Hz – 100 MHz
TBCP1-CAL Calibration fixture for TBPCP1-20100 current probe

History

Version Date Author Changes
V 1.0 4.2.2023 Mayerhofer Creation

www.tekbox.com
TekBox Digital Solutions Vietnam Pte. Ltd.
Factory 4, F4, Lot I-3B-1, Saigon Hi-Tech Park, Tan Phu Ward, District 9, Ho Chi Minh City, Vietnam

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals