TEKBOX TBPCP1-20100 RF Pulse Current Monitoring Probe Owner’s Manual
- June 9, 2024
- TEKBOX
Table of Contents
V1.0
TBPCP1-20100
RF PULSE CURRENT MONITORING PROBE
Introduction
The TBPCP1-20100 is a RF pulse current monitoring probe, expanding the Tekbox
product range of affordable test equipment.
The probe has a very flat response from 20 Hz to 100 MHz and is characterized
over the frequency range from 1 Hz to 200 MHz. The TBPCP1-20100 is typically
used for surge or RF pulse current monitoring applications in the time domain,
in contrary to RF current monitoring probes designed for EMC applications,
which are typically used for measurements in the frequency domain.
The aperture of the RF current monitoring probe is 25 mm. Its transfer impedance is -20 dB Ohm with a typical 3dB bandwidth from 20 Hz to 100 MHz.
Specification
Characterized frequency range: 1 Hz to 200 MHz
3 dB bandwidth: 20 Hz to 100 MHz (measured in a 50 + 50 Ohm loop)
Transfer impedance into 50 Ohm load: -20 dB Ohm; 0.1 V/A
Transfer impedance into high Z: 0.2 V/A
Probe port impedance: 50 Ohm
Droop rate: < 10% / ms
Rise time: < 5 ns
Max. CW primary RMS AC current with respect to internal resistor dissipation
ratings: 300A
Max. primary single pulse current with respect to internal resistor pulse
current ratings: 900A@ 100ms pulse width; 3000A @ 1ms pulse width Max. current
time product: 0.04 Ampere seconds
Max. RMS AC current, linear: 22 A
Max. core temperature: 80 °C
Aperture diameter: 25 mm
Outside diameter: 76 mm
Height: 31 mm
Weight: 320 g
Connector type: N female
Transfer impedance
Typical transfer impedance table
The table below shows typical transfer impedance data of a TBPCP1-20100 pulse
current probe. Each current probe is delivered with its corresponding
measurement protocol. The transimpedance is given for a 50 Ohm load.
Transimpedance [V/A] = 10^(dBOhm/20) @ 50 Ohm
Transimpedance [V/A] = 2*10^(dBOhm/20) @ High Z
Frequency| transfer impedance [dBΩ] 50 Ohm load| transfer
impedance [V/A] 50 Ohm load| transfer impedance [V/A] high Z load
---|---|---|---
1 Hz| -43,49| 0,007| 0,013
2,5 Hz| -35,00| 0,018| 0,036
5 Hz| -28,96| 0,036| 0,071
7.5 Hz| -25,98| 0,050| 0,101
10 Hz| -24,27| 0,061| 0,122
12.5 Hz| -23,23| 0,069| 0,138
15 Hz| -22,41| 0,076| 0,151
17.5 Hz| -21,89| 0,080| 0,161
20 Hz| -21,49| 0,084| 0,168
25 Hz| -21,03| 0,089| 0,178
50 Hz| -20,29| 0,097| 0,194
75 Hz| -20,11| 0,099| 0,198
100 Hz| -20,08| 0,099| 0,198
1 kHz| -20,06| 0,099| 0,199
10 kHz| -20,02| 0,100| 0,200
100 kHz| -20,01| 0,100| 0,200
1 MHz| -20,01| 0,100| 0,200
10 MHz| -19,99| 0,100| 0,200
25 MHz| -19,99| 0,100| 0,200
50 MHz| -20,01| 0,100| 0,200
60 MHz| -20,16| 0,098| 0,196
70 MHz| -20,29| 0,097| 0,194
80 MHz| -20,30| 0,097| 0,193
90 MHz| -20,06| 0,099| 0,199
100 MHz| -19,54| 0,105| 0,211
110 MHz| -18,39| 0,120| 0,241
120 MHz| -17,46| 0,134| 0,268
130 MHz| -17,13| 0,139| 0,278
140 MHz| -17,21| 0,138| 0,276
150 MHz| -17,49| 0,133| 0,267
160 MHz| -17,75| 0,130| 0,259
170 MHz| -18,17| 0,123| 0,247
180 MHz| -18,80| 0,115| 0,230
190 MHz| -19,37| 0,108| 0,215
200 MHz| -19,87| 0,101| 0,203
Table1: Transfer impedance: 1 Hz to 200 MHz, typical data
Accessory
Tekbox supplies a calibrator suitable for the TBPCP1-20100 current probe:
Ordering Information
Part Number | Description |
---|---|
TBPCP1-20100 | Pulse Current Probe 20Hz – 100 MHz |
TBCP1-CAL | Calibration fixture for TBPCP1-20100 current probe |
History
Version | Date | Author | Changes |
---|---|---|---|
V 1.0 | 4.2.2023 | Mayerhofer | Creation |
www.tekbox.com
TekBox Digital Solutions Vietnam Pte. Ltd.
Factory 4, F4, Lot I-3B-1, Saigon Hi-Tech Park, Tan Phu Ward, District 9, Ho
Chi Minh City, Vietnam
References
Read User Manual Online (PDF format)