SALTO RS485 Wireless BLUEnet Node and RFnet Node Installation Guide

June 16, 2024
SALTO

SALTO RS485 Wireless BLUEnet Node and RFnet Node

SALTO RS485 Wireless BLUEnet Node and RFnet Node

Installation guide

The BLUEnet Node and RFnet Node are part of SALTO wireless system. They work as a bridge, with the SALTO Gateway, between SALTO’s access control software and wireless locks.
Installation guide

Electrical characteristic

Operation conditions

Min Typ Max Unit
Temperature -20 25 70
Humidity 35 85

Cable requirements

RS485 Connection (AB) Generic twisted pair wire Note 1

Power Connection (Vdd): 24 AWG

Power Supply for SALTO RFnet

| Min| Typ| Max| Unit
---|---|---|---|---
Input Voltage| 7| 12| 28| V
Current consumption| | | 45 Note 2| mA

Power Supply for BLUENET

| Min| Typ| Max| Unit
---|---|---|---|---
Input voltage| -20| 25| 70| V
Current consumption RF Node| | | 45 Note 2| m A
Current consumption RFNet| | | 75 Note 2| m A

SALTO RFnet Characteristics

Frequency Range 2400-2483.5 Mhz
Standard IEEE 802.15.4
Indoor Radio   Range 10/15m
Max output power 5dBm

SALTO BLUEnet Characteristics

Frequency Range 2400-2483.5Mhz
RF Standard Bluetooth Low Energy
Indoor   Radio Range 5m/10m
Max output power 8dBm

Mechanical installation

1 GANG ELECTRICAL STANDARD BOX
Mechanical Installation
Mechanical Installation
Mechanical Installation

Electrical installation

RS485 bus termination resistor is needed (ON position) when the node is located at the end of the bus.
Electrical Installation

Installation example

Installation Example

Signalling

The green (RFnet Node) or blue (BLUEnet Node) LED of the device indicates that the device is properly powered.

Operational test

Once the product is installed, follow these steps to check the correct operation:
When SALTO Gateway and locks are installed, check that the RFnet Node or blueNET Node is active in SALTO’s software.

Maintenance

The unit should be tested at least once a year as described in “Operational test”. Keep the device in a safe place!

Radio information

The environment has a direct impact on the range radiation (metal, concrete walls…) The receiver device must be located facing the product antenna. Please check your product’s device antenna position.
Recommended connectivity distance: 5m – 10m

European view
All contents current at time of publication.
SALTO Systems S.L. reserves the right to change availability of any
item in this catalog, its design, construction, and/or materials.
2023 SALTO Systems S.L.