MVP GROUP IHP 2-12 Gas Countertop Hot Plate Instruction Manual
- June 16, 2024
- MVP GROUP
Table of Contents
MVP GROUP IHP 2-12 Gas Countertop Hot Plate Instruction Manual
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
Attention Owners and Operators
The equipment is designed to provide safe and productive processing, cooking and warming of food products as long as the equipment is used in accordance with the instructions in this manual and is properly maintained. Unless the operator is adequately trained and supervised there is a possibility of serious injury. Owners of this equipment bear the responsibility to make certain that this equipment is used properly and safely, and to strictly follow all of the instructions contained in this manual and the requirements of local, state or federal law.
Owners should not permit anyone to touch this equipment unless they are over 18 years old, are adequately trained and supervised, and have read and understood this manual. Do not attempt to repair or convert any gas types on your own. Repairs and conversions are to be made solely by an authorized local servicer.
Owners should also ensure that no customers, visitors or other unauthorized
personnel come in contact with this equipment. Please remember that supplier
cannot anticipate every circumstance or environment in which its equipment
will be operated. It is the responsibility of the owner and the operator to
remain alert to any hazards posed by the function of this equipment. If you
are ever uncertain about a particular task or the proper method of operating
this equipment, ask your supervisor
This manual contains a number of precautions to follow to help promote safe
use of this equipment. Throughout the manual you will see additional warnings
to help alert you to potential hazards.
Warnings affecting your personal safety indicated by:
If any warning labels or this manual are misplaced, damaged, or illegible, or
if you require additional copies, please contact your nearest representative
or vender directly for these items at no charge.
Please remember that this manual or the warning labels do not replace the need
to be alert, to properly train and supervise operators, and to use sense when
using this equipment.
Please remember that this manual or the warning labels do not replace the need
to be alert, to properly train and supervise operators, and to use sense when
using this equipment.
Model | GAS | Number Of Burners | BTU/hr Input Rating |
---|---|---|---|
12”-2 burners | Natural | 2 | 50,000 |
24”-4 burners | Natural | 4 | 100,000 |
36”-6 burners | Natural | 6 | 150,000 |
The appliance and it’s individual shutoff valve (to be supplied by user) must
be disconnected from the gas supply piping system during any pressure testing
of that system at test pressures in excess of ½ psi (3.45 kPa).
These models are designed, built, and sold for commercial use only.
Instructions must be posted in a prominent location. All safety precautions
must be taken in the event the user smells gas. Safety information can be
obtained from your local gas supplier.
UNPACKING
** Unpack the hot plate immediately after receipt. Remove the gas hot plate
from the crate; remove all packaging on and surrounding the unit and be
certain to remove all protective plastics and residues from all surfaces. Make
sure that all parts provided including the L.P. gas conversion kit are
located.
If the machine is found to be damaged, save the packaging material and contact
the carrier within five (5) days of delivery. Immediately contact IKON or your
local dealer of the equipment. You have no recourse for damage after fi ve
(5) days.**
Unpacking & Installation
INSTALLATION
-
Read this manual thoroughly before installation and operation. DO NOT proceed with installation and operation if you have any questions or do not understand anything in this manual. Contact your local representative.
-
Select a location for the hot plate that has a level, solid, nonskid surface that is nonflammable and away from water hazards or sinks, and is in a well-lighted work area away from children and visitors.
-
Equipment must be installed under proper ventilation as required per local code. NOTICE: Local codes regarding installation and ventilation vary greatly by area. The National Fire Protection Association, Inc, states in its NFPA 96 latest edition (see NFPA page at the beginning of this manual) that local codes are “authority having jurisdiction” when it comes to requirements for installation of equipment. Therefore, installation should comply with all local codes.
-
This appliance is equipped for Natural gas, for conversion to LP gas please see another conversion kits instruction.
-
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Legs must be installed to adequately provide proper ventilation to the unit.
-
Level unit by adjusting the four feet and tighten securely. The adjustable feet have an adjustment of one inch for lineup with other countertop Do not slide unit with legs mounted, lift if necessary to move unit.
-
The supplied gas pressure regulator is factory set at 4” Natural gas C. or 10” for L.P.
-
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
Noncombustible clearances: 0” sides (0 mm) 6” rear (152 mm) 4” floor (102 mm) -
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the Do not place objects between the bottom of the unit and the counter top.
-
There must be adequate clearance for removal of the front All major partsexcept the burners are removable thru the front if the gas line is disconnected.
-
It may be necessary to adjust the balance of gas volume and air supply to each burner. This must be done by an authorized service technician.
-
Pipe threading compound must be resistant to the action of liquefied petroleum
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water solution before operating unit.
COMMISSIONING:
Commissioning of your new hot plate is of the utmost importance. Commissioning is the thorough and methodical testing of the equipment, sub systems, and systems to ensure that the final product functions properly and safely at the work site. By identifying any potential problems (i.e.: equipment location, ventilation, local fire/electrical codes, installation, operator training and certification) prior to equipment being placed into service, costly outages and potential damages may be avoided.
SAFETY ALWAYS.
TO AVOID SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE:
For your safety, do not store or use gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliances. Keep the area free
and clear of combustible. ( See ANSI Z83. 14B, 1991).
Improper installation, adjustment, alteration, service or maintenance of this
equipment can cause property damage, personal injury, or death and voids
warranty. Read the installation operating and maintenance instructions
thoroughly before installing, or operating this equipment.
Instructions must be posted in a prominent location. All safety precautions
must be taken in the event the user smells gas. If you smell gas, immediately
shut off the main gas valve, extinguish all heat and flames, and call 911.
Safety information can be obtained from your local gas supplier.
IMPORTANT SAFEGUARDS & SAFETY INSTRUCTIONS
**** When using gas cooking equipment, basic safety precautions should always
be followed, including the following:
The hot plate burners, cooking grates and outside surfaces may become HOT
after use. Use caution when touching the unit.
- Never directly touch the burners or cooking grates while the hot plate is
- Always turn off the unit when not in use, servicing or adjusting any parts or attachments, and before
- Never leave the hot plate on
- Do not operate any equipment with a damaged or leaking gas line, ignitor or valves or if the unit is dropped or damaged in any manner. Call for service.
- The use of attachments not recommended or sold by the manufacturer may cause fire, injury or evendeath.
- Do not use
- Do not use this equipment for any use other than the use intended by the
- Never use the hot plate as a heating source
- The hot plate does not contain any user-serviceable Dealers or recommended qualified technicians should carry out repairs. Do not remove any components or service panels on this product.
- Never bypass, alter, modify or attach any unauthorized parts to this equipment. Doing so may create hazards and will void warranty
- Supplier takes every care to ensure that all products are safe. Steel cutting procedures used to manufacture these items result in sharp edges. These sharp edges are removed to the best of our ability; however, we insist the operator take care when in contact with this piece of equipment.
- Always keep hands, hair and clothing away from heating
- Allow the hot plate to cool down after use and before dismantling for cleaning; the unit will be too hot to handle immediately after use.
Operating Instructions
Operating the Hot Plate – Pilot Lighting Instructions
Before operating hot plate, it should be checked to see that it is sitting
level. Adjust the feet to level the hot plate. Be sure the catch tray has been
properly placed.
The pilot lights on the appliance have been set at the factory. Each burner
has a pilot light.
- Make sure all knobs are in the “OFF”
- The main gas valve should be “CLOSED/OFF” for five (5) minutes prior to lighting pilots to clear any existing gas. (Main gas valve is supplied by others.)
- Turn “ON/OPEN” the main gas valve to the
- Light and hold an ignition source (match) at the When the flame is
established, remove the ignition source. Repeat this step for each burner as each burner has its own individual pilot. The pilot can be reached through the holes in the front of the unit.
5, Adjust the pilot valve, make sure the pilot flame at 1/2 inch height.
6,Turn each burner knob “ON”. If the burners do not ignite promptly, turn the
knobs “OFF”. From the opening in the front panel, use a screwdriver and turn
the pilot valve screw counterclockwise which will increase the flame height
and repeat step 4.
The pilot flame should be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned to “ON”. The holes located in the front panel are pilot valve adjustments. Use a screwdriver to turn the valve to adjust the flame height to your desired level.
Igniting the Burner
To ignite the burner, turn knob to the “ON” position. Then back off to the
desired flame level. The range of adjustment is virtually infinite between
“ON” and “OFF”.
The space between the legs at the bottom admits combustion air. DO NOT BLOCK
THIS SPACE.
All burners are lit from constantly burning pilots. Turning the valve to the
desired flame height is all that is required to put the unit in service.
Do not permit fans to blow directly at the unit. Wherever possible, avoid open
windows next to the unit’s sides or back. Avoid wall type fans which create
air cross-currents within a room.
It is also necessary that sufficient air should be allowed to enter the room
to compensate for the amount of air removed by any ventilating system.
Otherwise, a subnormal atmospheric pressure will occur, affecting operation
and causing undesirable working conditions.
A properly designed and installed hood will act as the heart of the
ventilating system for the room or area in which the unit is installed, and
will leave the unit independent of changing draft conditions.
NOTE: It may be necessary to adjust the balance of gas, volume and air supply
to each burner. This must be done by an authorized service technician.
Shutdown burner
To turn ‘OFF’ the appliance completely, turn the gas control knob completely clockwise to the ‘O’ position, the pilot burner will extinguish.
- DO NOT use any abrasive or flammable cleaning
- DO NOT hose down, immerse or pressure wash any part of the hot plate, excluding the catch
- NEVER use a scrubber pad, steel wool or abrasive material, or cleaners containing chlorine, iodine and ammonia or bromine chemicals as these will deteriorate the stainless steel and shorten the life of the
IF CLEANING THE BURNER OF THE HOT PLATE, THE MAIN GAS VALVE MUST BE SWITCHED TO THE CLOSED POSITION. AFTER CLEANING, THE GAS LINE CAN BE SWITCHED BACK TO THE OPEN POSITION. PLEASE FOLLOW THE LIGHTING INSTRUCTIONS IN THIS MANUAL TO RELIGHT
THE HOT PLATE’S PILOT LIGHTS.
RECOMMENDED CLEANING
PART | REQUIRED ACTION | FREQUENCY |
---|---|---|
Grates | Wash with soap and water. | Daily |
Body | Use a clean cloth and a non-abrasive cleaner to clean the stainless | |
steel body of the hot plate. Wipe the polished areas with a soft cloth. | Daily | |
Controls | Unit should be turned off when not in use. It is recommended that |
the unit be disconnected from the gas supply by closing the main gas valve.
Use a clean cloth to wipe any down controls and/or knobs| Daily
Catch Tray| Once the unit has cooled, remove the catch tray and discard the
waste, debris and crumbs. CAUTION: If the catch tray is permitted to fill too
high, debris is likely to accumulate under the unit. The catch tray/drawer is
removed by pulling forward. USE CAUTION WHEN REMOVING!| per Use or at least
Daily
Burner Air Shutter Openings| Main burner ports must be kept clean. Close the
gas valve to the unit shutting of the gas and extinguishing the pilot light.
Clean in place with a wire brush or clean gas ports with a sharp-pointed metal
instrument to insure open ports or the burners may be removed and washed in
soapy water for 15-20 minutes.| As needed
Regulator| Make sure the vent opening is open and not blocked in any way.
Failure to do so will cause variations in pressure. Your unit will not
function as well and it could shorten the life of the product.| Monthly
It takes very little time and effort to keep the hot plate attractive and performing at top efficiency. Please follow the cleaning steps below:
RECOMMENDED CLEANING
It takes very little time and effort to keep the hot plate attractive and performing at top efficiency. Please follow the cleaning steps below:
Troubleshooting
ISSUE | CAUSE | SOLUTION |
---|---|---|
Hot plate not lighting | Main gas line is closed | Open valve |
Pilot light is not lit | Ignite pilot light | |
Cause unknown | Call for service | |
Flame is too high or too low | Adjustment knob is turned up or down | Adjust |
flame with control knob
Pilot light not staying lit| Flame is too low| Adjust pilot light flame height
Pilot tube clogged| Replace pilot tube. Call for service
Strong smell of gas in cooking area| Main gas line leak| Turn off main gas
valve. DO NOT LIGHT FLAME, ignite anything, or turn/switch on anything
electrical Call fire department if needed and call for service
Cooking surface is heating up slowly| Carbon build up| Ensure that the burners
are kept clean and free from carbon build up/ debris
Gas type of Unit needs to be converted| Unit ships from the factory Natural
gas. Conversion from Natural Gas to L.P. is possible for this unit| Contact an
authorized servicer. Do not attempt conversion on your own
If problems persist and the assigned solution does not remedy the issue, please call Service Department or your local service company.
IKON
– IMPORTANT SAFETY NOTICE –
These conversion instructions are for conversion of the HOT PLATE. The
instructions provide in this kit are for the conversion of Natural Gas to L.P.
gas and refer to the conversion of the unit and kit provided. An authorized
licensed technician must be called to perform the complete conversion of the
unit. Failure to properly convert this unit, can result in serious injury,
property damage or death and will void warranty.
Hot plate Conversion Kit Instructions
Do not attempt gas conversion by yourself. Gas conversion of your unit is to
be made by a certified/licensed technician.
CONVERSION
Instructions are for conversion from Natural Gas to Propane (L.P.) on all models. The conversion should b done before connecting the unit to the gas supply. Units are shipped from the factory equipped for use on natural gas. Parts necessary for L.P. (liquid propane) are provided with the unit. Turn off the main gas supply before doing any maintenance.
-
Remove the knobs and front panel.
-
Unscrew bolts and pilot valve, then remove he manifold.
-
Replace the orifice fittings into the valve.
Note: Unit Number on side of orifice fittings. -
Replace the front panel and knobs
-
Before installing the included convertible regulator, unscrew the octagon cap. You can read (NAT) on the plastic insert attached to the head of the cap; flip it over and snap back in place
Pictured is the plastic insert. Pull off insert from octagon cap and reverse
the plastic insert position so that the L.P. position is attached to the
octagon cap head
Continue with installation
Limited Warranty
IKON warrants to the original purchaser of new equipment that said equipment,
when installed in accordance with our instructions within North America and
subjected to normal use, is free from defects in material or workmanship for a
period of 1 year. The labor warranty is one year from original installation or
18 months from actual factory shipment date whichever date occurs first.
Warranty includes onsite service calls within 60 miles of an authorized
service company. End user is responsible for all extra travel and mileage at
prevailing rates.THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, WHETHER
EXPRESSED OR IMPLIED. IKONEXPRESSLY DISCLAIMS ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR EXPRESSED OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE.SERV-WARE’S OBLIGATION AND LIABILITY UNDER THIS WARRANTY IS EXPRESSLY
LIMITED TO REPAIRING AND REPLACING EQUIPMENT WHICH PROVES TO BE DEFECTIVE IN
MATERIAL OR
WORKMANSHIP WITHIN THE APPLICABLE WARRANTY PERIOD. All repairs pursuant to
this Warranty will be performed by an Authorized Designated IKON Service
Location during normal working hours. This warranty does not cover services
performed at overtime or premium labor rates. End user is responsible for the
difference between normal service rates and premium service rates. IN NO EVENT
SHALL IKONBE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES TO BUYER OR ANY
THIRD PARTY, INCLUDING, WITHOUT LIMITATION, LOSS OF PROPERTY, PERSONAL INJURY,
LOSS OF BUSINESS OR PROFITS OR OTHER ECONOMIC LOSSES, OR STATUTORY OR
EXEMPLARY DAMAGES, WHETHER IN NEGLIGENCE, WARRANTY, STRICT LIABILITY, OR
OTHERWISE.
This warranty is given only to the first purchaser from a retail dealer. No
warranty is given to subsequent transferees.
Warranty does not cover product failures caused by: failure to maintain,
neglect, abuse, damage due to excess water, fire, normal wear, improper set up
and use. Periodic maintenance is not covered.
This warranty is not in force until such time as a properly completed and
signed installation/warranty registration or an online registration form has
been received by IKON within 30 days from the date of installation.
Proof of purchase is required to extend warranty more than 1 year from date of
shipment from the factory.
THE FOREGOING WARRANTY PROVISIONS ARE A COMPLETE AND EXCLUSIVE STATEMENT
BETWEEN THE BUYER AND SELLER IKONNEITHER ASSUMES NOR AUTHORIZES ANY PERSONS TO
ASSUME FOR IT ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH SAID
EQUIPMENT.
Example of items not covered under warranty, but not limited to just these
items:
- Acts of God, fire, water damage, burglary, accident,
- Freight
- Improper installation or alteration of
- Use of generic or after-market
- Repairs made by anyone other than a IKON designated
-
- Expendable wear parts, adjustable feet, blown fuses, lamps,
- Cleaning of
- Misuse or
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>