REGIOLUX WOH-700 ET LED Light Installation Guide

June 16, 2024
REGIOLUX

REGIOLUX WOH-700 ET LED Light

Product Information

Specifications

  • Product Name: Leitungsschutzschalter/Leuchten
  • Model: WOH./700 ET, SOH./700 ET, WOH./700 DALI, SOH./700 DALI, WOH./1000 ET, SOH./1000 ET, WOH./1000 DALI, SOH./1000 DALI, WOH./1300 ET, SOH./1300 ET, WOH./1300 DALI, SOH./1300 DALI
  • Number of Circuits : 1-2
  • Maximum Load: 10-20 Amps
  • Certifications: C 16A

Product Usage Instructions

Step 1: Installation

Before installing the Leitungsschutzschalter/Leuchten, make sure to turn off the power supply to the circuit. Follow these steps for installation:

  1. Select a suitable location for the circuit breaker/luminaire.
  2. Connect the circuit breaker/luminaire to the electrical wiring according to the provided wiring diagram.
  3. Tighten the connections securely.
  4. Double-check the wiring to ensure it is correct and there are no loose connections.

Step 2 : Operation

To operate the Leitungsschutzschalter/Leuchten, follow these instructions:

  1. Turn on the power supply to the circuit.
  2. Use the provided controls or switches to adjust the lighting or control the circuit as needed.
  3. Monitor the circuit breaker/luminaire for any signs of malfunction or overheating during operation.

Step 3 : Maintenance

Maintaining is important to ensure its longevity and safe operation. Follow these maintenance guidelines:

  1. Regularly inspect the circuit breaker/luminaire for any visible damage or signs of wear.
  2. Clean the surface of the circuit breaker/luminaire using a soft cloth and non-abrasive cleaning solution, if necessary.
  3. Check the wiring connections periodically to ensure they are secure.
  4. If any issues or abnormalities are detected, contact the provided technical service for assistance.

FAQ

  • Q: Can I modify or rework the product?
    • A : No, any modification or reworking of the product can negatively impact its technical properties and may cause damage to other objects. The manufacturer cannot be held responsible for any damage caused by such changes.
  • Q: What does “d+ IP5x” and “d+ IP6x” mean?
    • A : “d+ IP5x” refers to the product’s dust nonconductive property, while “d+ IP6x” refers to its dust conductive and nonconductive property.
  • Q: How can I contact the technical service?
    • A: You can contact the technical service by phone at 09525 89-260, or by fax at 09525 89-261. Alternatively, you can send an email to service@regiolux.de.

Warning

Information

Wiring

Dimensions

Installation Instructions

  1. SDT-Basic mounting rail
  2. SDTE mounting rails on the front side
  3. rail connectors SDTSV
  4. chain hangers SDH
  5. Suspension chain KK
  6. Mounting angle set BW-SDT 235

Circuit breakers/luminaires

worker / sportier

WOH./700 ET              SOH./700 ET| 1| | ≤ 20|
---|---|---|---|---
WOH./700 DALI| SOH./700 DALI| 1| | ≤ 20
WOH./1000 ET            SOH./1000 ET| 2| | ≤ 12
WOH./1000 DALI| SOH./1000 DALI| 2| | ≤ 18
WOH./1300 ET            SOH./1300 ET| 2| | ≤ 10
WOH./1300 DALI| SOH./1300 DALI| 2| | ≤ 10

Contact

Please contact the technical service to determine your optimal driver configuration.

Subject to modifications

Service, Cleaning And Disposal

Information for service, cleaning and disposal of luminaire

Instruction for end of life

REGIOLUX-WOH-700-ET-LED-Light-fig13

  • switch off,
  • Remove battery witch off suply to luminaire for disposal
  • Remove luminair for disposal
  • Dispatch materials to WEEE recycling plant

Instruction for luminaire cleaning

REGIOLUX-WOH-700-ET-LED-Light-fig15 REGIOLUX-
WOH-700-ET-LED-Light-fig16

  • Clean luminaire
  • Switch off, switch off supply to luminaire
  • Clean outside luminaire
  • Remove optic
  • Clean inside luminaire
  • Refit optic
  • Make functional test

Safety Information

General Safety Information

  • Installation, commissioning and maintenance only by qualifi ed electrician.
  • Never perform any work on the luminaire with voltage applied. Danger to life due to electric shock!
  • Electric connection must be appropriate according to all applicable standards and other national and international safety and accident prevention regulations.
  • Damaged luminaires must not be operated.
  • Observe and retain safety instructions and mounting instructions
  • No liability is accepted for damages resulting from improper use.
  • Use genuine parts only for repair.
  • Ensure stability of the ceiling and fastening elements.
  • The luminaire is exclusively intended for interior rooms and ambient temperatures not exceeding 25°C, unless otherwise described by labeling the luminaire.

Operation of the luminaire

  • Abnormal dark spots may be an indication of partial failure of LEDs. Inspect regularly and replace the luminaires affected. The light source (LED) of this luminaire must not be exchanged or replaced by the user.
  • Exceeding the permissible ambient temperature will reduce the luminaire’s lifecycle, resulting in premature failure in extreme cases.
  • Avoid condensation of the luminaire.
  • Any mechanical load to the LED circuit boards is not permitted.
  • LEDs can be damaged by electrostatic discharge (ESD). This may result in total failure. Always avoid direct contact.
  • Depending on their concentration, chemicals can corrode the LED modules and lead to reduction of luminous fl ux, drift of luminous colour and/or total failure. Always avoid direct contact with acids, bases, solvents, volatile organic compounds and/or oils. Ensure suffi cient ventilation to prevent damage by gas release.
  • Avoid ESD problems by not routing feed-through wiring directly along the wiring of the luminaire.
  • Connect control inputs of dimmable luminaires with standard cables suitable for power supply voltage.

Changes to our products

Modification, reworking, re-marking of products can have a negative impact on their technical properties, destroy them and possibly cause consequential damage to other objects. The manufacturer cannot be held responsible for damage caused by such changes.

  • d+ IP5x – dust nonconductive
  • d+ IP6x – dust conductive and dust nonconductive
  • Regiolux GmbH Hellinger Sir. 3
  • D-97 486 Konigsberg/Bay.
  • T 09525 89-0
  • http://www.regiolux.de
  • info@regiolux.de

Safety instructions in your national language can be found on the Internet at: doc.regiolux.de/safety_BG.pdf

REGIOLUX-WOH-700-ET-LED-Light-fig-2..

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

REGIOLUX User Manuals

Related Manuals