Lupo COD.416 Superpanel Full Color 60 Soft RGBW LED Panel User Manual
- June 4, 2024
- Lupo
Table of Contents
- Lupo COD.416 Superpanel Full Color 60 Soft RGBW LED Panel
- SAFETY PRECAUTIONS:
- FINAL DISPOSAL
- Instructions
- Getting Started
- Functioning
- LIGHT MODES
- DEVICE SETTINGS
- RESET DEVICE
- Package Contents
- Update the Firmware
- MENU e submenus
- Introduction
- DMX Channel Protocol – 8 bit
- DMX Channel Protocol – 16 bit
- Protocol Specification
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Lupo COD.416 Superpanel Full Color 60 Soft RGBW LED Panel
SAFETY PRECAUTIONS:
Do not operate the equipment before studying the instruction manual and the
accompanying safety precautions. Make sure that Lupo Safety Instruction is
always included with the equipment! Lupo products are intended
for professional use. Do not place or use the equipment where it can be
exposed to moisture, extreme electromagnetic fields or in areas with flammable
gases or dust! Do not expose the equipment to hasty temperature changes in
humid condition as could lead to condensation water in the unit. Equipment
must only be serviced, modified or repaired by authorized. Dealers or the
factory.
CAUTION – BURN HAZARD – HOT PARTS
Do not touch hot parts with bare fingers! LED bulbs and certain metal parts
emit strong heat when used!
Do not point lamps too close to persons. Always use the fixtures with the
front part closed.
NOTICE – EQUIPMENT OVERHEATING RISK Do not obstruct ventilation by
placing filters, diffusing materials, etc. over inlets and outlets of the
equipment ventilation or directly over glass cover or LED bulbs.
FINAL DISPOSAL
Equipment contains electrical and electronic components that could be harmful to the environment.Equipment may be returned to Lupo distributors free of charge for recycling according to WEEE. Follow local legal requirements for separate disposal of waste, for instance WEEE directive for electrical and electronic equipment on the European market, when product life has ended.
MAINTENANCE AND CARE
Please do not forget that the safe operation of lampheads also includes their
maintenance and care. A visual inspection should be conducted before every use
and an inspection of electrical safety should be conducted at least once every
12 months.
WARRANTY
The warranty period for Lupo products and those marketed by Lupo is twelve
months from the date of delivery. Lupo guarantees that the goods it supplies
are well manufactured and of good quality. The warranty guarantees the repair
of any parts that show acknowledged defects in materials, construction or
workmanship during the warranty period. The guarantee excludes any liability
for direct or indirect damage of any kind and for any reason, for which Lupo
will therefore not be required to pay compensation. The customers shall see to
deliver the parts that need repair or replacement to Lupo’s works at their own
expense and risk. The repaired or replacement parts shall be delivered by Lupo
ex-works. The customers will be charged for materials and labor or replacement
of the product after the expiration of the warranty period.
WARNING: When hanging the fixture from higher position, please make sure
you use safety cable to attach the barndoors to the yoke of the panel.
Barndoors should always be used to secure the fixture and the application when
used in this way. Another safety cable should be used to secure the fixture to
the mounting pipe or truss. Both safety cables must be properly dimensioned
for the fixture and the application when the fixture is operated in hanging
position please ensure that the accessories are installed correctly with top
latch locked.
ATTENTION: Please keep the original package of the product in a safe place for warranty reasons. Thanks for having purchased Lupo products. All the products are made in Italy and all the efforts have been put to keep the quality standards high. We hope this product can help you in your job and make your life easier as a professional. We also hope you will enjoy its use and we would be happy to receive your feedback about it.
Instructions
- Device for indoor use only.
- Maximum ambient temperature: 40 °C.
- Make sure power supply plug is suitable to power required.
- As prescribed by international regulations, a safety cable must be used when the fixture is suspended from ceiling.
- To switch on the light push the on/off button.
- Superpanel models are equipped with new generation high quality powerleds.
Getting Started
Turning on the Superpanel
- Place the AC Adapters in the mounting brackets via the 2 captive screws to the bottom of the SUPERPANEL FULL COLOR 60 fixture.
- Insert the power cord cables into the AC adapters and connect the fixture to the power plug.
- Insert the DC XLR 4 pin connectors into the input jacks on the SUPERPANEL FULL COLOR 60 and power on the fixture.
Functioning
CONTROL PANEL
- In current mode press the 5 push button to enter the main MENU.
- In the sub-menus press the 5 push button to confirm a selection.
- Rotate the 5 knob to navigate in the main MENU and sub-menus.
- Use the « INTENSITY » 4 knob to adjust the light intensity from 0 to 100%.
- Use the knobs 5 and 6 to adjust the light mode parameters.
- Display 7 .
ATTENTION: The light intensity level is adjustable from 0 – 50% if the FAN is OFF. The value on the display flashes.
MANUAL OPERATION
- Press the 5 push button to enter the main MENU.
- Select MANUAL by pressing the 5 push button.
- Select the light mode between CCT / HSI / RGBW / PRESET / EFFECT with the 5 knob and press the 5 push button to confirm selection.
- See LIGHT MODES.
DMX OPERATION
- Press the 5 push button to enter the main MENU.
- Select DMX with the 5 knob and press the 5 push button to confirm selection.
- Select the light mode between CCT / HSI / RGBW / FRGBW / PRESET / EFFECT with the 5 knob and press the 5 push button to confirm selection.
- Select the DMX channel, rotating the 5 knob to change DMX ADDRESS in ascending or descending order between 1 and 512. The number shown on the display 7 is the selected channel to communicate with the control desk.
- See DMX PROTOCOL MANUAL to DMX channel specification.
NOTE: The symbol – ! – on the display indicates that there is no DMX signal.
BLUETOOTH
Enable / Disable BLE App interface
DMX OPERATION – Advanced Settings
- Press the 5 push button to enter the main MENU.
- Navigate through the main MENU with the 5 knob and press the 5 push button to confirm selection.
- Rotate the 5 knob to select DMX ADVANCED, press the 5 push button to confirm selection.
- Select one of the options among the DMX BIT, DMX SIGNAL LOSS and RDM ENABLE, press 5 push button to confirm the selection.
DMX BIT:
Resolution of the DMX control. 8bit 1 channel per function and 16 bit 2
channels per function.
- Select the DMX BIT item by pressing the 5 push button.
- Rotate the 5 knob to choose between 8bit / 16bit, press the 5 push button to confirm the selected setting. See DMX PROTOCOL MANUAL.
DMX SIGNAL LOSS:
This feature allows to choose the device’s behaviour in case of a DMX signal
loss.
- Select the LOSS DMX SIGNAL item with the 5 push button
- Rotate the 5 knob to select the device’s behaviour between BLACK OUT /SETTINGS LAST / SETTINGS 1min, press the 5 push button to confirm the setting.
Black out: The device switches off.
Settings Last: The values of the last selected setting are maintained
over time until the device is switched off.
Settings 1min: The values of the last selected settings is maintained for
one minute and then the device is switch off.
RDM Enable: ON/OFF, enable/disable RDM Protocol
LIGHT MODES
In CCT, HSI, RGBW and PRESET Mode, the key selects the STROBE page and the key
exits the STROBE PAGE.
In the STROBE PAGE it is possible to set DIMMER value and the STROBE frequency
by rotating the 5 button.
ATTENTION: STROBE frequency = 0 means STROBE effect OFF.
- CCT MODE: Warm and cold white control mode. It allows you to adjust colour temperature (CCT), green/magenta compensation (GN) and light intensity. This is the default setting.
- HSI MODE: Colour composition mode. It allows you to adjust hue of colour (HUE), colour saturation (SAT) and light intensity.
- RGBW MODE: RGBW colour control mode allows to individually set the R, G, B, W, Color Temperature (CT), green/magenta compensation (GN) values and to adjust light intensity
- FRGBW MODE: Available only in DMX operation. Same as RGBW but with white color power unlimited. See DMX PROTOCOL MANUAL.
- PRESET MODE: Mode with 53 PRESET colors, 48 factory preset and 5 user-defined preset.
- In MANUAL OPTIONS or DMX MODE menu select PRESET MODE.
- Select the PRESET to be activated rotate the 5 button, confirm the selection by pressing the 5 push button.
- Use the « INTENSITY » 4 knob to adjust the light intensity from 0 to 100%.
SAVING THE SET VALUES AS A PRESET
You can store up to 5 PRESETS.
- In MANUAL select SAVE PRESET by pressing the 5 push button.
- Save the set values in one of the available presets between USER PRESET 1 / 2 / 3 / 4 / 5 rotate the 5 knob to select the PRESET number and press the 5 push button to confirm the selection. THE SET COLOR IS SAVED AS PRESET. “BUSY” indicates that in the user preset there are parameters memorized if you select it, the parameters is replaced by the new ones. “EMPTY” indicates that the user preset is free.
SPECIAL EFFECT MODE: Mode with 11 SPECIAL EFFECTS. PARTY / COPCAR / DISCO 1 / DISCO 2 / TELEVISION BW / TELEVISION CO / PAPARAZZI / LIGHTNING / EXPLOSION /FIREWORKS / FIRE.
- In MANUAL OPTIONS or DMX MODE menu select EFFECT MODE.
- Select the EFFECT to be activated with rotate the 5 button, confirm the selection by pressing the 5 push button.
- In current mode, use the 1 o 3 button to change the EFFECT in ascending or descending order. THE EFFECT ON THE DISPLAY IS THE SELECTED EFFECT.
- Use the knobs 5 and 6 to adjust the effect setting values. See table below
EFFECT| 4 **INTENSITY knob| 5 ****CCT/HUE knob|
6 ****GN/SAT/COLOR knob
---|---|---|---
PARTY| **
Light Intensity from 0 to 100%
| Speed – 0 to 100%| –
COPCAR| Flash Color – B / R / R+B / B+W / R+B+W| Nº flashes for cycle – 1 to 4
DISCO 1| Speed – 0 to 100%| –
DISCO 2| Speed – 0 to 100%| –
TELEVISION BW| ****
Light Intensity from 0 to 100%
| White range – 1 / 2 / 3 / 4| Frequency – 4 to 24 Hz
TELEVISION CO| White range – 1 / 2 / 3 / 4| Frequency – 4 to 24 Hz
PAPARAZZI| Flashing Interval – 1 to 10| Bulb type – 0 / 1 / 2
LIGHTNING| Color Temperature| Lightnings Interval – 1 to 20
EXPLOSION| Speed – 1 to 60| –
FIREWORKS| Speed – 1 to 60| –
FIRE| Speed – 1 to 3| –
DEVICE SETTINGS
- Press the 5 push button to enter the main MENU.
- Navigate through the MENU rotating the 5 button, select DEVICE SETTINGS, press the 5 push button to confirm the selection.
- Navigate through the FAN / DISPLAY / MENU VIEW / FILTER / LINEARIZATION / CCT LIMIT functions, rotating the 5 button to select the desired function and press the 5 push button to confirm the selection.
- Within each function select the option to be activated and rotate the 5 button.
Fan: Fan operation. ON / OFF.
When the fan is OFF the light intensity is adjustable between 0 and 50%.
Display: Time during which the display backlight stays on. 30sec / 1min / ALWAYS ON.
Menu View: Type the main MENU, sub-menus and functions to show. ONLY MANUAL /ONLY DMX / MANUAL/DMX.
Filter: It is the speed response of the system (smooth factor).
FULL SPEED / NORMAL SPEED / HIGH SPEED / LOW SPEED.
Linearization: Linearization is the compensation curve for the human eye’s perception of the luminous intensity emitted as a function of the required power. Required power = dimmer value on the display. LINEAR / EXPONENTIAL / LOGARITHMIC.
Linear: No compensation, the intensity of the light is directly proportional to requested power.
Exponential: The light intensity increases from 0 to 100 exponentially.
Logarithmic: The light intensity increases from 0 to 100 logarithmically.
CCT Limit: The colour temperature is limited. 3200K – 5600K / 2800K – 10000K.
RESET DEVICE
- Press the « OK » 2 button to enter the main MENU.
- Select RESET DEVICE rotating the 5 button, press the 5 push button to confirm the selection.
- Select YES rotating the 5 button, press the 5 push button to confirm the selection.
- The device ask for further confirmation, select YES by pressing the press the 5 push button.THE DEVICE RETURN TO FACTORY DEFAULT SETTINGS.
Package Contents
USB port
Use USB port for firmware updates.
Update the Firmware
- Copy the file on an USB Pendrive (FAT32 formatted) in the main root;
- Switch off the equipment and insert the USB Pendrive;
- Switch on the equipment;
- Wait until display backlight flashes (it takes several minutes and red led must toggle for all time long);
- Switch off the equipment;
- Extract the Pendrive and switch on the equipment: the firmware is updated.
MENU e submenus
Introduction
The Actionpanel Full Color can be used with 8 bit or 16 bit DMX control.
(See DMX OPERATION – advanced settings in the user’s manual).
When used in 8 bit mode the Actionpanel Full Color uses one channel for each
function. DMX values for each channel are in the range of 0 to 255.
When used in 16 bit mode the Actionpanel Full Color uses two channels for each
function. The increased resolution offers a smooth dimming and a more accurate
color adjustment. DMX values for the first channel (byte 1) are in the range
of 256 to 65535 while for the second channel (byte 2) they are in the range of
0 to 255. The fixture use the number of channels required based on the light
mode selected CCT / HSI / RGBW /PRESET / PARTY / COPCAR / DISCO 1 / DISCO2 /
TELEVISION 1 / TELEVISION 2 / PAPARAZZI / LIGHTNING /EXPLOSION / FIREWORKS /
FIRE.
The Actionpanel Full Color uses consecutive channels starting from the DMX
channel set on the panel (DMX address) used as reference for the connection to
the control desk. Please take the above into consideration when using many
units of Actionpanel Full Color to avoid overlaps.
ATTENTION: The symbol – ! – on the display indicates that there is no DMX
signal.
DMX Channel Protocol – 8 bit
MODE | CHANNELS USED | DMX CHANNEL POSITION |
---|
CCT
| ****
4
| 1. DIMMER
2. COLOR TEMPERATURE
3. GN COMPENSATION
4. STROBE
HSI
| ****
4
| 1. DIMMER
2. HUE
3. SATURATION
4. STROBE
RGBW
| ****
8
| 1. DIMMER
2. RED
3. GREEN
4. BLUE
5. WHITE
6. COLOR TEMPERATURE
7. GN COMPENSATION
8. STROBE
FRGBW
| ****
8
| 1. DIMMER
2. RED
3. GREEN
4. BLUE
5. WHITE
6. COLOR TEMPERATURE
7. GN COMPENSATION
8. STROBE
PRESET
| ****
4
| 1. DIMMER
2. STROBE
3. PRESET
4. PRESET FREEZE
PARTY| 2| 1. DIMMER
2. SPEED
COPCAR
| ****
3
| 1. DIMMER
2. NUMBER OF COLORS
3. NUMBER OF FLASH
DISCO 1| 2| 1. DIMMER
2. SPEED
DISCO 2| 2| 1. DIMMER
2. SPEED
TELEVISION 1
| ****
3
| 1. DIMMER
2. WHITE RANGE
3. FREQUENCY
TELEVISION 2
| ****
3
| 1. DIMMER
2. WHITE RANGE
3. FREQUENCY
PAPARAZZI
| ****
3
| 1. DIMMER
2. INTERVAL
3. BULB TYPE
LIGHTNING
| ****
3
| 1. DIMMER
2. COLOR TEMPERATURE
3. INTERVAL
EXPLOSION| 2| 1. DIMMER
2. SPEED
FIREWORKS| 2| 1. DIMMER
2. SPEED
FIRE| 2| 1. DIMMER
2. SPEED
DMX Channel Protocol – 16 bit
MODE | CHANNELS USED | DMX CHANNEL POSITION |
---|
CCT
| ****
8
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. COLOR TEMPERATURE – byte 1
4. COLOR TEMPERATURE – byte 2
5. GN COMPRENSATION – byte 1
6. GN COMPENSATION – byte 2
7. STROBE – byte 1
8. STROBE – byte 2
HSI
| ****
8
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. HUE – byte 1
4. HUE – byte 2
5. SATURATION – byte 1
6. SATURATION – byte 2
7. STROBE – byte 1
8. STROBE – byte 2
RGBW
| ****
16
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. RED – byte 1
4. RED – byte 2
5. GREEN – byte 1
6. GREEN – byte 2
7. BLUE – byte 1
8. BLUE – byte 2
9. WHITE – byte 1
10. WHITE – byte 2
11. COLOR TEMPERATURE – byte 1
12. COLOR TEMPERATURE – byte 2
13. GN COMPENSATION – byte 1
14. GN COMPENSATION – byte 2
15. STROBE – byte 1
16. STROBE – byte 2
FRGBW
| ****
14
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. RED – byte 1
4. RED – byte 2
5. GREEN – byte 1
6. GREEN – byte 2
7. BLUE – byte 1
8. BLUE – byte 2
FRGBW
| ****
14
| 9. WHITE – byte 1
10. WHITE – byte 2
11. COLOR TEMPERATURE – byte 1
12. COLOR TEMPERATURE – byte 2
13. GN COMPENSATION – byte 1
14. GN COMPENSATION – byte 2
PRESET
| ****
8
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. STROBE – byte 1
4. STROBE – byte 2
5. PRESET – byte 1
6. PRESET – byte 2
7. PRESET FREEZE – byte 1
8. PRESET FREEZE – byte 2
PARTY
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
COPCAR
| ****
6
| 1. DIMMER – byte 1
---|---|---
2. DIMMER – byte 2
3. NUMBER OF COLORS – byte 1
4. NUMBER OF COLORS – byte 2
5. NUMBER OF FLASH – byte 1
6. NUMBER OF FLASH – byte 2
DISCO 1
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
DISCO 2
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
TELEVISION 1
| ****
6
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. WHITE RANGE – byte 1
4. WHITE RANGE – byte 2
5. FREQUENCY – byte 1
6. FREQUENCY – byte 2
TELEVISION 2
| ****
6
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. WHITE RANGE – byte 1
4. WHITE RANGE – byte 2
5. FREQUENCY – byte 1
6. FREQUENCY – byte 2
PAPARAZZI
| ****
6
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. INTERVAL – byte 1
4. INTERVAL – byte 2
5. BULB TYPE – byte 1
6. BULB TYPE – byte 2
LIGHTNING
| ****
6
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. COLOR TEMPERATURE – byte 1
4. COLOR TEMPERATURE – byte 2
5. INTERVAL – byte 1
6. INTERVAL – byte 2
EXPLOSION
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
FIREWORKS
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
FIRE
| ****
4
| 1. DIMMER – byte 1
2. DIMMER – byte 2
3. SPEED – byte 1
4. SPEED – byte 2
Protocol Specification
COMMAND | PID | DESCRIPTION |
---|
Manufacturer ID
|
0x0622
| Manufacturer identification number (LUPO Lighting).
Device Identification
Model ID| | Model identification number
| 0x0000| Dayled 650 mono color
| 0x0001| Dayled 650 dual color
| 0x0002| Dayled 1000 mono color
| 0x0003| Dayled 1000 dual color
| 0x0004| Dayled 2000 mono color
| 0x0005| Dayled 2000 dual color
| 0x0006| Superpanel 30 dual color soft
| 0x0007| Superpanel 30 dual color lens
| 0x0008| Superpanel 30 fullcolor soft
| 0x0009| Superpanel 30 fullcolor lens
| 0x0010| Superpanel 60 dual color soft
| 0x0011| Superpanel 60 dual color lens
| 0x0012| Superpanel 60 fullcolor soft
| 0x0013| Superpanel 60 fullcolor lens
| 0x0014| Actionpanel dual color soft
| 0x0015| Actionpanel dual color lens
| 0x0016| Actionpanel fullcolor soft
| 0x0017| Actionpanel fullcolor lens
| 0x0018| Kickasspanel dual color
| 0x0019| Kickasspanel fullcolor
| 0x0020| Lupoled monocolor
| 0x0021| Lupoled dualcolor
Personality| | DMX Personality
| 0x00| CCT
| 0x01| HSI
| 0x02| RGBW
| 0x03| FRGBW
| 0x04| PRESET
| 0x05| PARTY
| 0x06| COPCAR
| 0x07| DISCO 1
| 0x08| DISCO 2
| 0x09| TELEVISION BW
| 0x0A| TELEVISION CO
| 0x0B| PAPARAZZI
---|---|---
| 0x0C| LIGHTNING
| 0x0D| EXPLOSION
| 0x0E| FIREWORKS
| 0x0F| FIRE
Network management
DISC UNIQUE BRANCH| 0x0001| Search RDM devices
DISC MUTE| 0x0002| Mute RDM device, no response message
DISC UN MUTE| 0x0003| Activate RDM device fo response message
Status collection
QUEUED MESAGES| 0x0020| Retrieves queued messages or status message if no
message is in queue
STATUS MESSAGES| 0x0030| Retrieves current Warning/Error messages
RDM Information
SUPPORTED PARAMETERS| 0x0050| Retrieves a list of all supported RDM commands
PARAMETER DESCRIPTION| 0x0051| Retrieves a list of all RDM commands
Product Information
DEVICE INFO| 0x0060| Retrieves a variety of information about the device that
is normally required by a controller.
DEVICE MODEL DESCRIPTION| 0x0080| Text description of up to 32 characters for
the device model type.
MANUFACTURER LABEL|
0x0081
| This parameter provides an ASCII text response with the Manufacturer name
for the device. “LUPO” is the default name.
FACTORY DEFAULTS| 0x0090| Set the device to its factory defaults. Get: Check
if settings still in default state -> 1 if
default
SOFTWARE VERSION LABEL| 0x00C0| Retrieves software version string of main
software
DMX512 Setup
DMX PERSONALITY| 0x00E0| DMX mode
DMX PERSONALITY DESCRIPTION| 0x00E1| Shows a description of a DMX-Mode, max 32
characters
DMX START ADDRESS| 0x00F0| DMX address
Control
IDENTIFY DEVICE| 0x1000| The identify flag (flashes the light)
Manufacturer Commands
FAN MODE| 0x8001| 0: Off 1: On
DISPLAY TIMEOUT| 0x8002| 0: 30 sec 1: 1 min 2: always on
DMX SIGNAL LOST MODE| 0x8003| 0: black out 1: last settings on 2: last
settings 1 min
DMX BITS| 0x8004| 0: 8 bit 1: 16 bit
CCT LIMIT| 0x8005| 0: 2800-10000 1: 3200-5600
LINEARIZATION| 0x8006| 0: linear 1: exponential 2: logarithmic
FILTER| 0x8007| 0: full speed 1: normal speed 2: high speed 3: low speed
Lupo srl – Via V. Sassi 28/30 Collegno (TO) – 10093 – Italy
Phone: +39 011 411 9919
e-mail: contact@lupo.it
website: www.lupo.it
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>