REGIOLUX Turas Easy25 Surface Mounted Luminaires Instructions

June 15, 2024
REGIOLUX

Turas Easy25 Surface Mounted
Luminaires Instructions

Turas Easy25 Surface Mounted Luminaires

This luminaire contains a light soured of energy efficiency class CREGIOLUX
Turas Easy25 Surface Mounted Luminaires - fig 1

Dismantling

INSTRUCTION

SDG/1500 LED 1X RETRO TTL+ E14
1820 1360 229 Detached Motion Sensor With Bluetooth 5.0 SIG Mash

  • HCO38V
    1-10V Output

  • HCDO38
    DAU Output

  • HCD038/P

Product Description

HCO38V is o 1-10V control base whereas HCDO38 and HCDO38/P are DAU control bases with 30mA DALI power supply built in. They work with a wide range of microwave and PIR sensor heads. They are ideal for metal  luminaire designs because the Bluetooth module is placed inside the sensor heads instead of control base, so that the Bluetooth signal transmission is viable. They ore suitable for any typical indoor applications such as office, classroom, car park, warehouse and other commercial/industrial areas. With Bluetooth wireless mesh networking, it makes communicotion much easier without any hardwiring, which eventually adds values to luminaires and saves costs for projects. Meanwhile, simple device setup and commissioning can be done vio Maaimash” opp.
App Features
Grouping luminaires via mesh network

  • Two levels: room & group

  • Synchronization control
    7 types of scene options to set up:

  • Generic Scenes

  • Lux ON/OFF Scenes

  • Daylight Harvest (Open loop)

  • Daylight Harvest {Closed loop}

  • Simple circadian rhythm without daylight sensor (HCDO38 and HCDO38/P}

  • Advanced circadian rhythm with daylight sensor (HCDO38and HCDO38/P}

  • Time-based Scene
    Push switch configuration
    Detailed motion sensor settings

Hardware Features
HCO38V: 1-10V output with 400VA [capacitive] & BOOW [resistive] HCDO38& HCDO38/P: 30mA DALI broadcast output for up to 15 LED drivers
  Plugin’ Play for flexible installation and cost saving assemble
Support to control DT8 LED drivers (HCDO38 and HCD038/P} 2 Push inputs for flexible manual control (HCDO38/P only)
Zero crossing detection circuit to reduce in-ush current and prolong relay lifetime (HCO38V only)
Loop-in and loop-out terminals for efficient installation (HCO38V only}
5-year warranty

| Schedule to run scenes based on time and date
---|---
Astro timer [sunrise and sunset]
Floorplan feature to simplify project planning
Staircase function [master & slave}
Status after repowered on (memory against power loss]
Offline commissioning
Different permission levels viol authority management
Network shoring via QR code or keycode
Remote control via gateway support HBGWO 1
Interoperability with Hydronic Bluetooth product portfolio
Compatible with Encana range of wireless switches
Device firmware update over-the-air (OTA)
Continuous development in progress…

https://apps.apple.com/cn/app/koolmesh/id1483721878 https://play.google.com/store/apps/details?id=com.koolmesh.sig

Technical Specifications

Input & output Characteristics’

Operating voltage 220~-240VAC 50/60Hz
Stand-by power <0.S5W
load ratings:
HCO38V AOQOVA [capacitive]
HCDO38 800W (resistive)
HCD038/P 30mA [max. 15 devices)
Warming-up 20s

Safety & EMC

EMC standard (EMC} 55015, EN61000, EN61547
Safety standard (LVD} 60669-1 7-2-1, AS/NZS60669-1 /-2-1]
Radio Equipment (RED) 300440, EN301489-1/-3/-17 62479, EN300328
Certification Semko, CB, CE, EMC, RED, RCM

Environment

Operation temperature Ta: -20°C ~ +55°C
Case temperature (Max.} Tc: +75°C
IP rating , IP20

Mechanical Structure & Dimension Dimming Interface Operation Notes
Switch-Dim The provided Switch-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches. Detailed Push switch configurations can be set on Koolmesh app.

Switch Function Action Descriptions
Push switch Short press (<0.4 second)
* Short press has to be longer than 0.1 s, or it will be invalid. – Turn on/off – Recall o scene

– Turn on only – Exit manual mode
– Turn off only – Do nothing
Double push| – Turn on only – Exit manual mode
– Turn off only – Do nothing
– Recall o scene
Long press (>0.4 second)| – Dimming
– Colour tuning – Do nothing
Simulate sensor| /| – Upgrade normally on/off motion sensor to a Bluetooth controlled motion sensor

Additional Information / Documents

  1. Regarding precautions for Bluetooth product installation and operation, please kindly refer to www.hytronik.com/download/knowledgeBluetoothProducts – Precautions for Product Installation and Operation
  2.  Regarding precautions for microwave sensor installation and operation, please kindly refer to www.hytronik.com/download/knowledgeMicrowaveSensors – Precautions for Product Installation and Operation
  3. Data sheet is subject to change without notice. Please always refer to the most recent release on www.hytronik.com/products/bluetoothtechnologyBluetoothSensors
  4.  Regarding Hydronic standard guarantee policy, please refer to www.hytronik.com/download/knowledgeHytronik Standard Guarantee Policy

Wire Preparation To make or release the wire from the terminal, use o screwdriver to push down the bunion,
Wring Diagram

Technical Specifications for Sensor Heads

Bluetooth Transceiver

Operation frequency 2.4 GHz – 2.483 GHz
Transmission power 7 dBm
Range (Typical indoor] 10~30m
Protocol ‘5.0 SIG Mesh

HF Sensor Priorities (HBT01)

Sensor principle High Frequency {microwave}
Operation frequency 5.8GHz +/-75MHz
Transmission power <0.2mW
Detection range* Max. ( x H] 8m x 3m
Detection angle 30° ~ 150°

Environment

Operation temperature -20°C ~ 55°C
Storage temperature Ta: -20°C ~ +70°C
Relative humidity 0 ~90%
IP rating IP20

PIR Sensor Properties (HIR13 / HIR16)

Sensor principle PIR detection
Operation voltage 5VDC
Detection range * HIR13x (xH) 16mx12m

HIR16 (LxWxH) 18mx dmx 15m
Detection angle| 360°

The range of PIR and microwave sensor heads below with Bluetooth modules built in offers powerful number of Plug ‘n Play feature options to expand the Hexibility of luminaires design. This approach to luminaire design reduces space requirements and component costs whilst simplifying production.
A. HBTOT
Surface mounting The coble length is around 30cm.
B. HBTO2
Surface mounting Without motion sensor The cable length is around 30cm.
C. HIR13/S
Surface mounting For highboy application Lens part IP42 (IP64 can be mode upon request] The cable length is around 30cm. D. HIR13/F
Flush mounting
For highboy application Lens port IP42 (IP64 can be made upon request!) The cable length is around 30cm.
E. HIR13/C
Screw to the luminaire by conduit For highboy application lens part IP42 (IP64 can be mode upon request} The cable length is around 30cm.
F.HIRI6
PIR sensor head For highboy application IP65{lens part} The cable length is around 30cm.
Installation for HIR16
We suggest that the metals plate thickness to be 0.8mm~- 1.6mm to ensure perfect focal length for the PIR lens.

Detection Pattern
HBTO1

The detection range is heavily influenced by sensor placement (angle) and different walking paces.
It may be reduced to [  x H) of 2 x 3m under certain conditions (walking across}.

Safety Information

General Safety Information

  • Installation, commissioning and maintenance only by qualified electrician.
  • Never perform any work on the luminaire with voltage applied. Danger to life due to electric shock!
  • Electric connection must be appropriate according to all applicable standards and other national and intemational safety and accident prevention regulations.
  •  Damaged luminaires must not be operated.
  •  Observe and retain safety instructions and mounting instructions
  •  No liability is accepted for damages resulting from improper use.
  •  Use genuine parts only for repair.
  •  Ensure stability of the ceiling and fastening elements.
  •  The luminaire is exclusively intended for interior rooms and ambient temperatures not exceeding 25°C, unless other- wise described by labeling the luminaire.

Opertion of the luminaire

  • Abnormal dark spots may be an indication of partial failure of LEDs. Inspect regularly and replace the luminaires affected. The light source (LED) of this luminaire must not be exchanged or replaced by the user.
  • Exceeding the permissible ambient temperature will redu- ce the luminaire’s lifecycle, resulting in premature failure in extreme cases.
  •  Avoid condensation of the luminaire.
  •  Any mechanical load to the LED circuit boards is not permitted.
  •  LEDs can be damaged by electrostatic discharge (ESD). This may result in total failure. Always avoid direct contact.
  •  Depending on their concentration, chemicals can corrode the LED modules and lead to reduction of luminous flux, drift of luminous colour and/or total failure. Always avoid  direct contact with acids, bases, solvents, volatile organic
  • mpounds and/or oils. Ensure sufficient ventilation to prevent damage by gas release.
  •  Avoid ESD problems by not routing feed-through wiring directly along the wiring of the luminaire.
  •  Connect control inputs of dimmable luminaires with standard cables suitable for power supply voltage.

Changes to our products
Modification, reworking, re-marking of products can have a negative impact on their technical properties, destroy them and possibly cause consequential damage to other objects. The manufacturer cannot be held responsible for damage
caused by such changes.

  • + IP5x – dust nonconductive
  • + IP6x – dust conductive and dust nonconductive

Information for service, cleaning and disposal of luminaire
Instruction for luminaire service:
Replace aged or failed LED

Instruction for end of life:

Switch off, switch off supply to luminaire| Remove battery for disposal| Remove luminaire for disposal| Dispatch materials to WEEE recycling plant
---|---|---|---
| | |

Instruction for luminaire cleaning
Clean luminaire

SELV! Only SELV!

Switch off, switch off supply to luminaire| Clean outside luminaire| Remove optic| Clean inside luminaire| Refit optic| Make functional test
| | | | |

The safety instructions in your country’s language need The Internet.

https://doc.regiolux.en/safety_EN.pdf

REGIOLUX
Regiolux GmbH
Hellinger Str. 3
D-97486 K~nigsberg/Bay.
Telefon (0 95 25) 89-0
Telefax (0 95 25) 89 73 4
http://www.regiolux.de
e-Mail: info@regiolux.de

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals