BEGA 51271.1K3 Pendant Luminaire Instruction Manual
- June 15, 2024
- BEGA
Table of Contents
51 271.1
Pendant luminaire for indoor use
Instructions for use
51271.1K3 Pendant Luminaire
****
Application
Pendant luminaire – Indoor luminaire with ringshaped light source for
unshielded and uniform light, light-diffusing silicone diffuser and metal
ring.
As single luminaires or in arrangements, they are creative lighting design
solutions for interior design.
Lamp
Module connected wattage | 34.7 W |
---|---|
Luminaire connected wattage | 39 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
51 271.1 K3
Module designation | LED-1396/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 5400 lm |
Luminaire luminous flux | 3747 lm |
Luminaire luminous efficiency | 96,1 lm / W |
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
Product description
Luminaire housing made of synthetic material, finish colour velvet white
Ring and round inlay made of metal, finish colour velvet white
Diffusor made of translucent ageing-resistant silicone
Synthetic canopy, finish colour velvet white
Round inlay made of metal in the canopy, finish colour velvet white
Mounting plate with 2 fixing holes ø 4.5 mm · 86 mm spacing
Cable pendant · Sheath cable white 2 x 0,75@
Synthetic 2-piece line connector (clamp part with screw cap) for braided
coaxial cables
With internal pressure spring and contact wire
Overall length of luminaire approx. 2000 mm
Connecting terminals 1,5@
Earth conductor terminal
LED power supply unit inside canopy
220-240 V ≂ 0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
A basic isolation exists between power cable and control line
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
– Conformity mark
This product contains light sources of energy
efficiency class(es) D
Weight: 1.2 kg
Prior to installation, please note:
The canopy is not equipped with throughwiring of the power connecting cable by
the manufacturer.
However, if suitable installation components are used, through-wiring may be
carried out by the customer.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Remove the pendant luminaire and canopy from the packaging.
Detach the canopy downwards from the mounting plate against the magnetic
resistance.
Push the canopy downward on the luminaire cable.
Place the pendant luminaire on the mounting plate and make markings for the
mounting holes on the ceiling.
NOTE: If multiple pendant luminaires are to be installed in a row, the
arrows imprinted on the mounting plate are helpful for precise orientation in
a line.
Pass the power connecting cable through the cable entry in the mounting plate.
Fasten the mounting plate with the supplied fastening material or other
suitable fastening material to the installation surface.
Establish the earth conductor connection on the lateral earthing screw ( ****)
of the bracket of the mounting plate.
Make the electrical connection (L) and (N) via the power supply unit
terminals. Observe the correct configuration of the connecting cable.
For digital control please use the connecting terminals DA, DA at the power
supply unit .
In case these connectors are not used the luminaire will be operated at full
light output.
Slide the canopy towards the ceiling until it is held securely in place by the
holding magnets of the mounting plate.
For fine adjustments to the pendant luminaire, the canopy can be rotated by
+/- 10° around the vertical canopy axis in its final position.
Trimming the cable pendant
The cable may only be trimmed above in the canopy.
Disconnect the system from the mains.
Detach the canopy downwards from the mounting plate against the magnetic
resistance.
Push the canopy downward on the luminaire cable.
IMPORTANT: Ensure the pendant luminaire is held firmly in place when
setting the desired suspension height!
Remove the connecting wires of the luminaire cable red and black from the
power supply unit.
Unscrew the coaxial cable connector and remove the luminaire cable from the
lower part of the connector.
To adjust the suspension height, loosen the locking screws (Torx T10) of the
strain relievers on both luminaire cables, adjust the cable length and tighten
the locking screws again.
Shorten the excess length on the non-live luminaire cable so that an overhang
of 1020 mm remains above the strain relief.
Shorten the excess luminaire cable on the live luminaire cable so that a
projection of 140150 mm remains above the strain reliever.
Please consider these 140-150 mm when cutting the cable to the required
length.
Strip 60 mm to max. 80 mm of the insulation from the luminaire cable at the
top end.
Installing the coaxial cable connector
Guide the stripped cable end (A) into the lower part of the connector (clamp
part) (B) until it stops.
Hold the luminaire cable below the lower part of the connector.
Carefully push together the coaxial mesh of the stripped section with two
fingers of your other hand bit by bit directly above the connector thread,
until the black wire is laid bare.
Make sure that the coaxial mesh is inserted into the recess on the lower part
of the connector – see diagram (C).
Guide the black wire through the opening in the middle of the screw cap.
Make sure that the red wire is correctly positioned in the cap with the
internal pressure spring. Screw the closing cap (top part of the connector) in
clock-wise direction onto the clamp part (lower part of the connector) until
it stops (D).
Strip back 7–8 mm of the black wire (E).
Connect red wire to “+” and black wire to “-” on the marked power supply unit
terminals.
Slide the canopy towards the ceiling until it is held securely in place by the
holding magnets of the mounting plate.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system from the power supply.![BEGA 51271 1K3 Pendant Luminaire
- FIGURE 2](https://manuals.plus/wp-content/uploads/2023/12/BEGA-51271-1K3
-Pendant-Luminaire-FIGURE-2.jpg)Release both of the inserted metal discs of
the luminaire housing from the housing groove by applying slight pressure on
the upper edge, and remove them against the magnetic force.
Disconnect the two-pin LED plug connector.To replace the LED module with diffuser, it is necessary to open the round luminaire housing.
Hold the pendant luminaire by the luminaire housing and, using a suitable tool, apply pressure to the three snap-in hooks of the luminaire housing until the housing cover releases from the latch.
Remove the LED module with the diffuser from the holder. Install the replacement module.
Please follow the installation instructions for the new LED module.
A defective luminaire cover must be replaced.
Reconnect the two-pin LED plug connector.
Make sure that both luminaire cables are correctly positioned in the cable routing of the luminaire housing.
Place the housing cover on the lower part of the housing with the snap-in hook and snap it into place by applying pressure.
Reinsert the previously removed metal discs into the magnetic housing recesses on both sides.
Spares
LED power supply unit
LED module 3000 K with diffusor
Round blank (inlay)
BEGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
References