alphacool ES Orbiter Filling Station Instruction Manual
- June 15, 2024
- ALPHACOOL
Table of Contents
- Accessories
- Parts identification
- Technical specifications
- Dimensions
- Installation of the water connections
- If require, mount TPV connector
- Fill coolant
- Check minimum filling level
- Connect to the power source
- Open service flap, if necessary
- Change fuel filter
- Error messages and fault corrections
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Alphacool
ES Orbiter Filling Station
https://www.alphacool.com/m/safety.pdf
https://www.alphacool.com/m/?acg=1012
Accessories
Parts identification
- Powerbutton
- Fillport (G1″)
- Woter inlet and outlet (G1/4″)
- Level indicator
- Handle
- Service flap
- Input power plug
- Supporting feet
Technical specifications
F Alphacool ES Orbiter Filling Station
Art.no. 13093
Approved liquids
Water, Water/Glycol mixture
Voltage 12v DC
Approved water pressure 0,8 Bor
Pumping height max. 3,125m
Fillport 1x GT”
Approved operating temperature 75°C
Water connections 2x G1/4″
Power consumption Sow
Technical specifications
H Alphacool pump VPP755 – Single Edition V.3
Art.no. 13294
Rate of flaw
350l/h
Power input
14w
Voltage
12v oc
I Liquid Reservoir
Volume (tank capacity)
approx. 4500ml
J Alphacool tube AlphaTube TPV 12,7/7,6 – black matt (10ft) retail bax
Art.no, 18605
Material
TPV
Operating temperature
-50°C to 155°C
K Alphacaol HF compression fitting TPV metal – 90° rotatable 12,7/7,4mm –
black Art.no. 17455
L Alphacool HF compression Fitting TPV – 12,7/7,46mm straight – black – 6pcs
Kit Art.no, 17453
Dimensions
Installation of the water connections
If require, mount TPV connector
The components to be filled are then connected to the quick-release fasteners. This is an example configuration.
Fill coolant
Do not operate the Filling Station without coolant!
Check minimum filling level
Watch the fill level and refill with coolant if necessary.
Connect to the power source
The Filling Station starts as soon as it is connected to the power supply and the powerbutton is pressed. A second press on the powerbutton interrupts the power supply.
Open service flap, if necessary
All maintenance work must be carried out by qualified personnel only.
Change fuel filter
Previously drain water from the device.
All maintenance work must be carried out by qualified personnel only.
Error messages and fault corrections
The pumps makesnoticeable noises?
Fault Cause
There are air bubbles in the system and/or cooling liquid is missing.
Approach
Open the fillport, refill with coolant if necessary. Observe the minimum
filling level.
The system does not pump water?
Fault Cause
One or both pumps is defective and/or the current supply is not present.
Approach
Check the pump by a qualified technician and/or get the pump or pumps
exchanged and/or check the plug connections and power supply unit, replace if
necessary.
Water leaks from the system?
Fault Cause
The connections and/or the hoses are incorrectly mounted and/or defective.
Approach
Switch off the device, check the connections and/or the hoses, tighten if
necessary or get the parts exchanged .
The Filling Station does not start?
Fault Cause
The power supply is defective and/or the power plug is not connected properly.
Approach
Replace the power supply and/or check the current supply.