alphacool ES Orbiter 360 TS External Water Cooling Instruction Manual
- June 15, 2024
- ALPHACOOL
Table of Contents
- Accessories
- Dimensions in mm
- Parts identification
- Technical specifications
- Installation of the water connections
- Fill coolant
- Connect to the power source
- Check minimum filling level
- Error messages and fault corrections
- CUSTOMER SUPPORT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
alphacool ES Orbiter 360 TS External Water Cooling
Accessories
-
1x Funnel G1/4
-
1x Power Supply 120cm
-
1x Power Plug 50cm
Dimensions in mm
Parts identification
- Water inlet and outlet (G ¼”)
- Ergonomically shaped handle
- Air vents
- Input power plug
- Supporting feet
- Fillport
Technical specifications
-
Approved liquids
Water, Water/Glycol mixture -
Cooling capacity
1300W [at 23′ ambient temperature) -
Voltage
12V DC -
Approved water pressure
0,8 Bar -
pumping height max,
3,125m -
Fillport
1x G1/ 4″ -
Approved operating temperature
75 ‘C -
Water connections
2x G1/ 4″ -
Air balance
1x G1/ 4″ -
Power consumption
17,7W
Alphacool NexXxoS HPE-30 Full Copper 240mm Radiator
Art.Nr, 14376
Installation of the water connections
Fill coolant
Do not operate the orbiter without coolant!
Connect to the power source
The Orbiter starts as soon as it is connected to the power supply.
Check minimum filling level
During first commissioning, the filling level may drop because air escapes
from the individual components.
Watch the fill level and refill with coolant if necessary.
Error messages and fault corrections
The pump makes noticeable noises?
Fault Cause
There are air volumes in the system or cooling liquid is missing.
Approach
Open the vent port, refill with coolant if necessary.
Observe the minimum filling level.
The warning signal sounds?
Fault Cause
The pump and/or a fan has failed.
Approach
Drain the water, check the unit by a qualified technician and/or return the
failed part.
The system does not pump water?
Fault Cause
The pump is defective.
Approach
Check the pump by a qualified technician and/or return the pump.
Water leaks from the system?
Fault Cause
The connections and/or the hoses are incorrectly mounted and/or defective.
Approach
Switch off the device, check the connections and/or the hoses, tighten if
necessary or return the parts.
The Orbiter does not start?
Fault Cause
The power supply is defective and/or the power plug is not connected properly.
Approach
Replace the power supply and/or check the power supply.
The temperature is too high?
Fault Cause
The air supply is impeded and/or the power to be cooled of 1500 watt is
exceeded.
Approach
Clean the ventilation from dust and/or reduce the power of the heat sources,
connect a second orbiter if necessary.