MEAN WELL LPV-20 series 20W Single Output Switching Power Supply Owner’s Manual

June 15, 2024
MEAN WELL

MEAN WELL LPV-20 series 20W Single Output Switching Power Supply

MEAN-WELL-LPV-20-series-20W-Single-Output-Switching-Power-Supply-
PRO

Features

  • Constant voltage design
  • Universal AC input / Full range
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Over load / Over voltage
  • Cooling by free air convection
  • Small and compact size
  • Fully encapsulated with IP67 level (Note.7)
  • Fully isolated plastic case
  • Class II power unit, no FG
  • Class 2 power unit
  • Pass LPS
  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices)(Note. 11)
  • 100% full load burn-in test
  • Low cost, high reliability
  • 2 years warranty

MEAN-WELL-LPV-20-series-20W-Single-Output-Switching-Power-
Supply-2

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

SPECIFICATION

MODEL LPV-20-5 LPV-20-12 LPV-20-15 LPV-20-24
OUTPUT DC VOLTAGE 5V 12V 15V
RATED CURRENT 3A 1.67A 1.33A 0.84A
CURRENT RANGE 0 ~ 3A 0 ~ 1.67A 0 ~ 1.33A 0 ~ 0.84A
RATED POWER 15W 20W 20W 20.2W
RIPPLE & NOISE (max.) **Note.2** 80mVp-p 120mVp-p 120mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME Note.6 500ms, 20ms / 230VAC  500ms, 20ms /

115VAC at full load
HOLD UP TIME (Typ.)| 50ms/230VAC            16ms/115VAC at full load
INPUT| VOLTAGE RANGE| Note.4| 90 ~ 264VAC           127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 77%| 81%| 83%| 83%
AC CURRENT (Typ.)| 0.55A/115VAC  0.35A/230VAC
INRUSH CURRENT(Typ.)| COLD START 70A(twidth=215μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| 0.25mA / 240VAC
PROTECTION| OVER LOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 5.75 ~ 6.75V| 13.8 ~ 16V| 17.5 ~ 21V| 28 ~ 32V
Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS| Ul879, UL1310, CSA C22.2 No. 207-M89,CAN/CSA C22.2 No. 223-M91,IEC/BS EN/EN 62368-1, IS 15885(Part2/Sec13)(NOTE 12), EAC TP TC 004,IP67 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS| MTBF| 6025.8K hrs min.       Telcordia SR-332 (Bellcore) ; 786.5Khrs min.| MIL-HDBK-217F (25℃)|
DIMENSION| 1183526mm (LWH)
PACKING| 0.22Kg; 60pcs/14.2Kg/0.72CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
9. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
10. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
11. This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
12. Products sourced from the China regions may not have the BIS logo, please contact your MEAN WELL sales for more information. https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN-WELL-LPV-20-series-20W-Single-Output-Switching-Power-
Supply-3

Recommend Mounting Direction

MEAN-WELL-LPV-20-series-20W-Single-Output-Switching-Power-
Supply-4

Block Diagram

MEAN-WELL-LPV-20-series-20W-Single-Output-Switching-Power-
Supply-5 MEAN-WELL-LPV-20
-series-20W-Single-Output-Switching-Power-Supply-6