This installation guide provides simple function information on PLC control. Please read carefully this data sheet and manuals before using products. Especially read safety precautions and handle the products properly.
Safety Precautions
Meaning of warning and caution inscription
WARNING
indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
indicates a potentially hazardous situation that, if not avoided, may
result in minor or moderate injury. It may also be used to alert against
unsafe practices.
WARNING
- Do not contact the terminals while the power is applied.
- Protect the product from being gone into foreign metallic matter.
- Do not manipulate the battery(charge, disassemble, hitting, short, soldering).
CAUTION
- Be sure to check the rated voltage and terminal arrangement before wiring.
- When wiring, tighten the screw of the terminal block with the specified torque range.
- Do not install flammable things in the surroundings.
- Do not use the PLC in an environment of direct vibration.
- Except for expert service staff, do not disassemble fix or modify the product.
- Use the PLC in an environment that meets the general specifications contained in this datasheet.
- Be sure that the external load does not exceed the rating of the output module.
- When disposing of PLC and battery, treat it as industrial waste.
Operating Environment
To install, observe the below conditions
Applicable Support Software
For system configuration, the following version is necessary.
- XGI CPU: V2.1 or above
- XGK CPU: V3.0 or above
- XGR CPU: V1.3 or above
- XG5000 Software : V3.1 or above
Parts Name and Dimension (mm)
This is the front part of the CPU. Refer to each name when driving the system. For more information, refer to the user manual.
Installing / Removing Modules
Here describes the method to attach each product to the base or remove it.
- Installing module
- Slide the upper part of the module to fix it to the base, and then fit it to the base by using the module-fixed screw.
- Pull the upper part of the module to check if it is installed to the base completely.
- Removing module
- Loosen the fixed screws of the upper part of the module from the base.
- Hold the module with both hands and press the fixed hook of the module thoroughly.
- By pressing the hook, pull the upper part of the module from the axis of the lower part of the module.
- By lifting the module upward, remove the fixed projection of the module from the fixing hole.
Performance Specifications
Wiring
Precaution for wiring
- Don’t let the AC power line near to analog module’s external input/output signal line. With enough distance kept between them, it will be free from surge or inductive noise.
- Cable shall be selected in due consideration of ambient temperature and allowable current. More than AWG22 (0.3㎟) is recommended.
- Don’t let the cable be too close to the hot device and material or in direct contact with oil for long, which will cause damage or abnormal operation due to short-circuit.
- Check the polarity when wiring the terminal.
- Wiring with a high-voltage line or power line may produce inductive hindrance causing abnormal operation or defect.
Wiring examples
Voltage input
- Use a 2-re twisted shielded wire.
- The Input resistance voltage input is 250Ω(typ.).
- The Input resistance current input is 1㏁(min.).
Warranty
- Warranty period: 18 months after the production date.
- Scope of Warranty: 18-month warranty is available except:
- The troubles caused by improper conditions, environment or treatment except for the instructions of LS ELCECTIC.
- The troubles caused by external devices are the troubles caused by remodelling or repairing based on the user’s discretion.
- The troubles caused by improper usage of the product
- The troubles caused by the reason that exceeded the expectations from the science and technology level when LS ELECTRIC manufactured the product
- The troubles caused by natural disasters
Change in specifications
Product specifications are subject to change without notice due to continuous product development and improvement. LS ELECTRIC Co., Ltd. www.ls- electric.com 10310000984 V4.4 (2021.11)
- E-mail: automation@ls-electric.com
- Headquarters/Seoul Office Tel: 82-2-2034-4033,4888,4703
- LS ELECTRIC Shanghai Office (China) Tel: 86-21-5237-9977
- LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China) Tel: 86-510-6851-6666
- LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam) Tel: 84-93-631-4099
- LS ELECTRIC Middle East FZE (Dubai, U.A.E.) Tel: 971-4-886-5360
- LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands) Tel: 31-20-654-1424
- LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan) Tel: 81-3-6268-8241
- LS ELECTRIC America Inc. (Chicago, USA) Tel: 1-800-891-2941
- Factory: 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnamdo, 31226, Korea