NINGBO UX33US 4G Multi Mode Engineering Gateway Instruction Manual
- June 15, 2024
- Ningbo
Table of Contents
4G Multi-mode Engineering(BLE+ZigBee) Gateway
Product instruction manual and three packs of cards
UX33US 4G Multi Mode Engineering Gateway
WARNING
This is an A-level product. In the living environment, this product may cause
radio interference. In this case, it may be necessary for users to take
practical and feasible measures against interference.
Declaration of toxic and harmful substances in electronic information products
Part | Toxic and harmful substances or elements |
---|---|
Pb | Hg |
Plastics | |
Metal | |
PCBA |
This table has been prepared in accordance with the provisions of SJ/T11364-2014.
O: Indicates that the content of the toxic and harmful substance in all
homogeneous materials of the part is below the limit requirements stipulated
in GB/T26S72-2011;
X : Indicates that the toxic and harmful substances are at least contained ina
homogeneous material of the component that exceeds the limit requirements
specified in the GB/T26572-2011 standard.
The environmental protection period of the digital identification products in
the normal use State in this label is 10 years, and some components may also
have environmental protection service life identification, and the
environmental service life is subject to the number in the logo.
Warranty Policy
The after-sales service of the 4Gmulti-mode engineering gateway is strictly based on the “Law of the People’s Republic of China on the Protection of Consumer Rights and Interests” and the “Product Quality Law of the People’s Republic of China”, and the after-sales three-guarantee service is implemented, and the service content is as follows
- Within 7 days from the date of your signature, if the product has a product performance failure, you can enjoy the return or exchange service for free.
- Within 8-15 days from the date of receipt, the product has a product performance failure, and you can enjoy free replacement or maintenance services;
- Within 12 months from the date of receipt, the product has a product performance failure, and you can receive free maintenance services.
Non-warranty regulations
- Unauthorized repair, misuse, collision, negligence, abuse, liquid intake, accident, alteration, use of parts other than this product, or tearing or altering labels or security marks;
- The validity period of the three packs has exceeded,
- Damage caused by force majeure,
- Other damage or failure caused by other problems such as design, technology, manufacturing, and quality of the product itself.
Micro power device description
-
Specific terms and usage scenarios in accordance with the “Catalogue and Technical Requirements for Micropower Short Range Radio Transmission Equipment”, antenna types and performance used, control, adjustment, and switch usage methods;
1, Usage scenario: When users control other related devices through the gateway, the gateway communicates with other related devices through Zigbee.
2,Antenna type and performance: Zigbee frequency range 2.405-2.480ghz; Transfer rate: 250Kbps ; Zigbee EIRP Powers10dbm; Antenna type: External pole antenna.
3, Control, adjustment, and switch usage methods: After the gateway device is powered on and automatically turned on, the Zigbee function automatically starts, and users do not need to adjust it. -
Do not change the usage scenario or conditions, expand the transmission frequency range, increase the transmission power (including the installation of additional RF power amplifiers), and do not change the transmission antenna without authorization;
-
It is not allowed to cause harmful interference to other legitimate radio stations (stations), nor is it allowed to propose protection from harmful interference;
-
Industrial, scientific, and medical (ISM) application equipment that should withstand interference from radiated radio frequency energy or other legitimate radio station interference;
-
If harmful interference is caused to other legitimate radio stations, they should be immediately stopped from use and measures should be taken to eliminate the interference before continuing to use;
-
The use of low-power equipment in aircraft and in the electromagnetic environment protection areas of military and civilian radio stations (stations), airports, etc., such as radio observatories, meteorological radar stations, satellite earth stations (including measurement and control, ranging, reception, navigation stations) established in accordance with laws, regulations, relevant national regulations, and standards, shall comply with the regulations of electromagnetic environment protection and relevant industry authorities;
-
Prohibit the use of various model remote controls in areas with a radius of SOOO meters centered around the center point of the airport runway;
-
Environmental conditions of temperature and voltage during the use of micro power devices;
Operating ambient temperature: -10°C ~ 55°C
Working voltage: DC 5V
Three-pack voucher
Name………………. TEL Loe……………….
Model………………. Date ow…………………
Three-pack voucher
Name………………. TELL……………..
Model……………… Date………………..
Product introduction
4G multi-mode engineering gateway has 4G-LTE, WiFi, Bluetooth, ZigBee communication functions. Through the smart light control App, users can remotely add other related devices and reset the Bluetooth /ZigBee group control, etc., to meet the requirements of intelligent scenarios.
4G | 4G Antenna |
---|---|
BT | BT Antenna |
ZigBee | ZigBee Antenna |
Wi-Fi | WiFi Antenna |
RJ45 | RJ45 Network Connect |
DC | PWR Connect |
SIM | SIM Card Connect |
SET | Set Key |
RES | Reset Key |
PWR | PWR LED |
NET | Distribution Network LED |
Instructions for use
- Search for” Light+tSpace “in the app store or scan the QR code below, download and install the App and register an account;
- Wait for 30s on the device until the blue light flashes and the device enters the state of the network to be distributed;
- Open the ” Light+Space “App and follow the following prompts for network distribution operations:
[ Wireless Pairing ]
a. Click “+” in the upper right corner to be automatically discovered by the
device or manually add “Gateways and Others — Wireless Gateway (Bluetooth)”;
b. Press and hold the RES key 5s, confirm that the gateway “Network” blue
light flashes, and click Next;
c. The App automatically searches for “Multimode Engineering Gateway”, click
“+” on the right side of the device name;
d. Enter your WIFI account and password, and click Next;
e. The right side of the device name displays a green “Vv”, click Next, click
Finish, assign the device to the space you specified, and the binding is
complete.
[ Wired Pairing ]
a. Use the network cable to connect the gateway to the router to ensure that
the mobile phone WIFI and the gateway are in the same LAN;
b. Click “+” in the upper right corner to manually add “Gateways & Others —
Wired Gateways (ZigBee)”;
¢. Press and hold the RES key 5s, confirm that the gateway “Network” blue
light flashes, and click Next;
d. App automatically searches for “multi-mode engineering gateway”, click “+”
on the right side of the device name;
e. The device automatically distributes the network operation, after
completing the registration, the right side of the device name displays a
green “vy”, click Next, click Finish, assign the device to the space you
specified, and the binding is completed.
[Set the 4G APN]
a. Click “4G multi-mode engineering gateway” after the gateway is successfully
configured.
b. After entering the gateway screen, tap Settings to enter the APN setting
screen.
c. Enter the carrier name and carrier APN number, and save the Settings
[Add sub-device ]
Press the SET key, and the gateway automatically binds searchable BLE or
ZigBee sub-devices.
https://smartapp.tuya.com/lightingcom
Key Operation Instructions
SET Button| Short press the SET button, the blue light will flash slowly
(1500ms/time) to enter the long distribution network mode (1 hour), and the
device will automatically add sub devices.
Short press again to exit the sub device addition mode.
RES Button| After pressing and holding for 5 seconds, the blue light will
remain on and the device will enter a reset state. After a successful reset,
the blue light will flash quickly (500ms/time) and the device will enter a
waiting network state.
| Indicator Light Status Description
---|---
Device Status| Indicator Light Status Description
Wating Distribution Network| Blue light flashing rapidly (500ms/time)
Successful Distribution Network| The device is successfully connected to the
cloud, and the blue light remains on for 5 seconds before turning off.
Add Child Devices| Blue light flashing slowly (1500ms/time)
Power on In Inactive State| All lights remain on until the program starts.
After the program starts, the blue light flashes quickly (500ms/time),
and the device enters a waiting network state.
Power off And Then on In Activated State| All lights stay on until the program
starts. After the program starts, the blue light flashes quickly (500ms/time).
If the device is successfully connected to the cloud, the blue light stays on
for Ss and then goes off.
Activated State Reset| After long pressing the RES button for 5 seconds, the
blue light will remain on. After the program restarts, the blue light will
flash quickly (500ms/time) and enter the waiting network state.
Product specifications
Product Name | 4G Multi-mode Engineering Gateway |
---|---|
Product Modle | UX33 |
Power Input | 5V ****2A |
Working Temperature | -10°C ∼ 55°C |
Working Humidity | 10%∼90%RH (non-condens i ng) |
NetWork Support | Wi-Fi 2.4G |
BLE 4. 2
ZigBee
LTE CAT1
Product Size| 127. 8203179rmi (With Antenna)
Product Net Weight| 316g
This device is an LTE single-antenna device, which is suitable for the application scenarios that require low data transmission rate
Packing list
4G Multi-modeEngineering Gateway 1
Instructions1
Adapter1
Antenna5
Screw pack*1
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any inte rference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interferenceto radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
with minimum distance 20cmbetween the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>