MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter Owner’s Manual

June 15, 2024
Mitsubishi Heavy

MITSUBISHI HEAVY logo EXTERIOR DIMENSIONS
Models SRK10YL-S, 13YL-S, 18YL-S

Indoor units

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter Space for installation and service when viewing from the front

Symbol Content
A Gas piping

Model 18 0 12.7 (1/2″) (Flare)
B| Liquid piping| 06.35 (1/4″) (Flare)
C| Hole on wall for right rear piping| (65)
D| Hole on wall for left rear piping| (65)
E| Drain hose| VP16
F| Outlet for wiring|
G| Outlet for piping (on both side)|

Wireless remote control

Note 1The model name label is attached on the underside of the panel.

Outdoor units

Models SRC10YL-S, 13YL-S

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure
2MITSUBISHI HEAVY SRK10YL-S Air
Conditioner Inverter - FIgure 3

Notes

  1. It must not be surrounded by walls on the four sides.
  2. The unit must be fixed with anchor bolts. An anchor bolt must not protrude more the 15mm.
  3. Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
  4. Leave 1m or more space above the unit.
  5. A wall in front of the blower outlet must not exceed the units height.
  6. The model name label is attached on the lower right comer of the front panel.

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.

Symbol Content
A Service valve connection (gas side)
B Service valve connection (liquid side)
C Pipe/cable draw-out hole
D Drain discharge hole
E Anchor bolt hole

Models SRC18YL-S

MITSUBISHI HEAVY SRK10YL-S Air Conditioner Inverter - FIgure
5MITSUBISHI HEAVY SRK10YL-S Air
Conditioner Inverter - FIgure 6

Notes

  1. It must not be surrounded by walls on the four sides.
  2. The unit must be fixed with anchor bolts. An anchor bolt must not protrude more than 15mm.
  3. Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction.
  4. Leave 1m or more space above the unit.
  5. A wall in front of the blower outlet must not exceed the units height.
  6. The model name label is attached on the lower right corner of the front panel.

Note(1) If the wall is higher than 1.2 m or a ceiling is present, distances larger than indicated in the above table must be provided.

Symbol Content
A Service valve connection (igas side)
B Service valve connection (iliquid side)
C Pipe/cable draw-out hole
D Drain discharge hole
E Anchor bolt hole