Rsrteng X7 Series Security Camera Tester User Manual
- June 12, 2024
- Rsrteng
Table of Contents
Rsrteng X7 Series Security Camera Tester
Product Information
The X7 Series Camera Tester is a versatile device designed for testing and troubleshooting security cameras. It is available in multiple versions, including the Basic version (X7), X7-ADH, X7-ADHS, and X7-MOVTADHS. The current version of the user manual is V01.00.
Safety Information
- The tester should only be used in compliance with local electrical usage rules and not in places where electrical devices are prohibited, such as hospitals or gas stations.
- Avoid exposing the tester to water or damp environments to prevent functional decline or failure.
- Do not touch the exposed parts of the tester with dust or liquid.
- Avoid violent collisions and vibrations during transportation and use to prevent damage to components and failure.
- Do not leave the tester unattended while charging or recharging. If the battery becomes severely hot, discontinue use.
- Never connect the meter to any voltage source while the function switch is in current, resistance, capacitance, diode, or continuity mode, as it may damage the meter.
- Ensure capacitors are fully discharged before performing capacitance measurements.
- Avoid measuring resistance, capacitance, diode, or continuity on live circuits.
- Exercise caution when using visual laser sources to avoid eye damage. Do not stare at the laser source and always turn it off when not in use.
IP Camera Tester Introduction
The IP Camera Tester is a general-purpose device used for testing IP
cameras. It comes with various accessories and features to facilitate testing
and troubleshooting.
Packing List
- Tester
- Adaptor DC12V/2A
- Network cable tracer
- V5-H Polymer lithium-ion battery (in tester, 7.6V 7800mAh, 59.28Wh)
- BNC cable
- RS485 cable
- SC, ST connector (Only for X7-MOVTADHS)
- Multi-meter test leads (one pair of red and black, only for X7-MOVTADHS)
- Output Power cable
- Audio cable
- TDR alligator clamp (Only for X7-MOVTADHS)
- 8GB SD card
- Safety cord
- Tool bag
- User manual
Function Interface
The X7 Series Camera Tester features a user-friendly interface with various
controls and functions:
- Power button: Press and hold for more than 2 seconds to turn the device on or off. Short press to toggle the menu display.
- Menu key: Press to access the short menu.
- 4x zoom: Zoom in on the displayed image.
- Far focus: Adjust focus for distant objects.
- Near focus: Adjust focus for nearby objects.
- TELE+: Zoom in further on the image.
- WIDE-: Zoom out from the image.
- Open/set: Confirm parameter settings and open or enlarge the aperture.
- Return/Close: Go back or cancel while setting parameters in the menu, and close or decrease the aperture.
- Upward: Tilt the PTZ (Pan-Tilt-Zoom) camera upward.
- Rightward: Select the parameter whose value will be changed and add the value of the parameter. Pan the PTZ camera to the right.
SECURITY CAMERA TESTER
X7 Series User Manual
X7(Basic version) X7-ADH X7-ADHS X7-MOVTADHS
V01.00
Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera tester and use properly. For using the IP camera tester safely, please first read theSafety Information carefully in the manual. The manual should be kept well in case of reference. Keep the S/N label for after- sale service within warranty period. Product without S/N label will be charged for repair service. If there is any question or problem while using the IP camera tester, or damages occurred on the product, please contact our technical Department. service@rsrteng.com or view WWW.RSRTENG.COM
X7 SERIES CAMERA TESTER User Manual
Safety information
The tester is intended to use in compliance with the local rules of the
electrical usage and avoid to apply at the places which are inapplicable for
the use of electrics such as hospital, gas station etc. To prevent the
functional decline or failure, the product should not be sprinkled or damped.
The exposed part of the tester should not be touched by the dust and liquid.
During transportation and use, it is highly recommended to avoid the violent
collision and vibration
of the tester, lest damaging components and causing failure. Don’t leave the
tester alone while charging and recharging. If the battery is found severely
hot, the
tester should be powered off from the electric source at once. The tester
should not be charged over 8 hours. Don’t use the tester where the humidity is
high. Once the tester is damp, power off immediately and move away other
connected cables. The tester should not be used in the environment with the
flammable gas. Do not disassemble the instrument since no component inside can
be repaired by the user. If the disassembly is necessary indeed, please
contact with the technician of our company. The instrument should not be used
under the environment with strong electromagnetic interference. Don’t touch
the tester with wet hands or waterish things. Don’t use the detergent to clean
and the dry cloth is suggested to use. If the dirt is not easy to remove, the
soft cloth with water or neutral detergent can be used. But the cloth should
be tweaked sufficiently. About Digital Multi-meter Before using, you must
select the right input jack, function and range. Never exceed the protection
limit values indicated in specifications for each range of measurement. When
the tester is linked to a measurement circuit, do not touch unused terminals.
Do not measure voltage if the voltage on the terminals exceeds 660V above
earth ground. At the manual range, when the value scale to be measured is
unknown beforehand, set the range selector at the highest position. Always be
careful when working with voltages above 60V DC or 40V AC, keep fingers behind
the probe barriers while measuring.
Page.1.
X7 SERIES CAMERA TESTER User Manual
Never connect the meter with any voltage source while the function switch is
in the current, resistance, capacitance, diode, continuity, otherwise it will
damage the meter.
Never perform capacitance measurements unless the capacitor to be measured has
been discharged fully.
Never measure any of resistance, capacitance, diode or continuity measurements
on live circuits. Visual laser sources When you turn on visual laser sources,
please don’t stare at it, or will damage to eyes When not using it, please
turn it off and cover the protective cap.
2. IP Camera Tester Introduction
2.1 General
The Rsrteng 7 inch touch screen IP camera tester is designed for maintenance
and installation of IP cameras, analog cameras, 8MP TVI, 8MP CVI, 8MP AHD,
8MP EX-SDI cameras, as well as testing 4K H.264 /4K H.265 camera via
mainstream, The 1920×1200 resolution enables it to display network HD cameras
and analog cameras in high resolution. The unit supports many ONVIF PTZ and
analog PTZ control. The combination of touch screen and key buttons make the
IP camera tester very user-friendly. The tester is also a great tool for
Ethernet network testing. It can test PoE power voltage, PING, and IP address
searching. You can use the blue cable tracer to locate individual connected
cables from a bundle of cables. Test LAN cable for proper connection
termination. Other functions include providing 25.5W PoE power to your camera,
HDMI IN and OUT, CVBS loop test, testing IP and analog at the same time, LED
Flashlight, DC 12V 3A, DC 24V 2A, power output and much more. Its portability,
user-friendly design and many other functions make the IP tester an essential
tool for all installers or technicians.
Page.2.
X7 SERIES CAMERA TESTER User Manual
Packing list
1). Tester 2). Adaptor DC12V/2A 3). Network cable tracer 4). V5-H Polymer
lithium ion battery (in tester, 7.6V 7800mAh, 59.28Wh) 5). BNC cable 6). RS485
cable 7). SC, ST connector (Only for X7-MOVTADHS) 8). Multi-meter test leads
one pair of red and black(Only for X7-MOVTADHS) 9). Output Power cable 10).
Audio cable 11). TDR alligator clamp (Only for X7-MOVTADHS) 12). 8GB SD card
13). Safety cord 14). Tool bag 15). Manual
WWW.RSRTENG.COM
Page.3.
2.3 Function interface
X7 SERIES CAMERA TESTER User Manual
Press more than 2 seconds, turn on or off the device, short press to turn on
or 1
off the menu display
2
Menu key, press it to call short- menu.
3
4xzoom the image displays.
4
Far focus: Focus the image faraway
5
Near focus: Focus the image nearby
6
TELE+: zoom in the image
7
WIDE-: zoom out the image
8
Open/set, Confirm the setting of parameters, open or enlarge the aperture
Return/Close: Return or cancel while setting parameters of the menu, close or
9
decrease the aperture
WWW.RSRTENG.COM
Page.4.
X7 SERIES CAMERA TESTER User Manual
10
Upward, set function or add parameter. Tilt the PTZ upward
Rightward, select the parameter whose value will be changed. Add the value of
11
the parameter. Pan the PTZ right
Downward, set function or reduce the value of the parameter. Tilt the PTZ 12
downward
13
Leftward, select the parameter whose value will be changed
14
Confirm key,(Long press it to capture screen interface)
Return/Close : Return or cancel while setting parameters of the menu, close or
15
decrease the aperture
16
Multi-meter interface* (Only for X7-MOVTADHS)
The charge indicator: it lights red while the battery is being charged. As the
17
charging is complete, the indicator turns off automatically
The RS485 data transmission indicator: it lights red while the data is being
18
transmitted
19
The data received indicator: it lights red while the data is being received
The power indicator: it lights green while the tester is powered on by the 20
adapter
WWW.RSRTENG.COM
Page.5.
Top interface
X7 SERIES CAMERA TESTER User Manual
Bottom interface
21 Visible red laser source emits Interface (Only for X7-MOVTADHS)
22 DC12V3A power output, for provisional DC power supply 23 PSE power sourcing
equipment (Tests PoE voltage) / LAN test port / RJ45 TDR 24 PoE power supply
output (Use to test PoE or non-PoE IP camera) / LAN port / RJ45 TDR 25 Optical
power meter interface (Only for X7-MOVTADHS) 26 CVBS/AHD/TVI/CVI video input
BNC interface (Only for X7-MOVTADHS, X7-ADHS,
X7-ADH) 27 CVBS video signal output BNC interface / Cable tracer BNC interface
28 HDMI IN 29 RS485 Interface: RS485communication for the PTZ
30 HD-SDI/EX-SDI input BNC interface (Only for X7-MOVTADHS, X7-ADHS)
WWW.RSRTENG.COM
Page.6.
X7 SERIES CAMERA TESTER User Manual
31 TDR cable test BNC interface (Only for X7-MOVTADHS)
32 LED lamp 33 TDR cable test RJ45 interface (Only for X7-MOVTADHS) 34 HDMI
output interface 35 Micro SD card moveable,(comes with 8GB, supports up to
32GB) 36 UTP cable tester port / Cable tracer RJ45 interface 37 USB 5V 2A
power output 38 Audio output and earphone interface. 39 Audio input 40 DC 24V
2A output 41 DC 12V 2A charging interface. 42 Power switch 43 Microphone
Operation
3.1 Installing the Battery
The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery
cabin should be disconnected for safety during transportation!
Prior to the use of the instrument, the battery cables inside the battery cabin should be well
connected. Usually it doesn’t need to disconnect the cable at the normal use.
Pressing the key
continuously can power on or off the tester.
Notice: Please use the original adaptor and connected cable of the device! When the battery icon is full or the charge indicator turns off automatically, indicate the battery charging is completed.
Notice: When the Charge Indicator
turns off, the battery is approximately 90% charged.
WWW.RSRTENG.COM
Page.7.
X7 SERIES CAMERA TESTER User Manual
The charging time can be extended for about 1 hour and the charging time within 12 hours will not damage the battery.
Notice: Press the key
several seconds to restore the default settings when the
instrument works abnormally. Multi-meter: the red and black multi-meter pen must insert the corresponding port.
Warnings: Instrument communication port is not permitted access circuit voltage over 6V, otherwise damage the tester.
Warnings: Not allow insert multi-meter pen in the current terminal to measure voltage.
3.2 Instrument connection
3.2.1 IP camera connection
Power an IP camera with an independent power supply, then connect the IP
camera to the IPC tester’s LAN port, if the link indicator of the tester’s LAN
port is green and the data indicator flickers, it means the IP camera and the
IPC tester are communicating. If the two indicators don’t flicker, check if
the IP camera is powered on or the network cable is not functioning properly.
WWW.RSRTENG.COM
Page.8.
X7 SERIES CAMERA TESTER User Manual
Note: 1) If the IP camera requires PoE power, then connect the IP camera to
the IP tester’s LAN port. The
tester will supply PoE Power for the IP camera. Click the icon POE to turn the
PoE Power off or on. 2) If use the tester’s menu to turn off the tester’s PoE
power supply, the PoE switch and the power
sourcing equipment are allowed to connect to the tester’s PSE port, and the
PoE power will be supplied to the IP camera by the tester’s LAN port. On this
condition, the tester cannot receive data from IP camera, but the computer
connected to the PoE switch can receive the data via the the tester.
Warning: PoE switch or PSE power sourcing equipment only can be connected to
tester “PSE IN” port, otherwise will damage the tester.
3.2.2 Analog camera connection
- Connect the camera’s video output to the IP tester’s VIDEO IN. The image will display on the tester after pushing the PTZ icon.
WWW.RSRTENG.COM
Page.9.
X7 SERIES CAMERA TESTER User Manual
2) CCTV IP Tester “VIDEO OUT” interface connect to the Video input of monitor
and optical video transmitter and receiver, the image display on the tester
and monitor. 3) Connect the camera or the speed dome RS485 controller cable to
the tester RS485 interface.(Note: positive and negative connection of the
cable)
3.2.3 HD Coaxial camera connection
CVI, TVI, AHD, SDI camera are classified as HD coaxial cameras. Hereby the
following instruction of how to connect SDI camera to the tester is also
applied to CVI, TVI and AHD camera.
- Connect the SDI camera’s video output to the IP tester’s “SDI IN”
interface, the image will display on the tester. The tester only come with SDI
input interface. There is no SDI output interface. 2) Connect the SDI camera
or the speed dome RS485 controller cable to the tester RS485 interface.
3.2.4 HDMI IN
WWW.RSRTENG.COM
Page.10.
X7 SERIES CAMERA TESTER User Manual
DVR or other device’s HDMI out port connect to tester’s HDMI in port, the meter will display input image.
3.2.5 HDMI output
The built in HDMI output port can output live video from an analog or IP
camera, recorded files, media files and images to HDTV monitors. Connect an
HDMI cable from the IP tester to an HDTV monitor at any time. It supports up
to 1080P resolution.
3.3 OSD menu
Press the key
2 seconds to turn on
Press the key
again to turn off
short press the key
to enter sleep mode, press it again to test.
If tester works abnormally and cannot be turned off, Press the key
off, the tester reset.
several seconds to turn
3.3.1 Drop-down Menu
Press and slide at right top right corner twice to open shortcut menu. The
shortcut menu includes POE power output, IP settings, Wi-Fi, HDMI IN, CVBS,
Video OUT, LAN, Brightness, settings etc.
HDMI: Click HDMI IN to enter, In HDMI IN mode, it can converter test from analog to digital with dual test window IP & HDMI in or Analog & HDMI in. CVBS: Click icon “CVBS” to enter, you can test IP and analog camera at the same time.
WWW.RSRTENG.COM
Page.11.
X7 SERIES CAMERA TESTER User Manual
TV OUT: Click TV OUT to enter floating window, connecting the BNC cable to
tester and appears analog video monitor interface, it can test circuit and BNC
cable whether normal. LAN: Display network port or WIFI connection real-time
upload and download speeds and other network parameters. Settings: Enter
settings interface. IP: Enter IP Settings interface. POE power output: Turn on
or off the tester “PoE power” app.
3.3.2 Short cut-menu
You can call shortcut menu by press tester’s “menu” key, you can self- define
shortcut -menu.
Press the key
, you can turn on it, and switch functions, then press
area on the screen, to exit the menu.
to enter app, tap other
WWW.RSRTENG.COM
Page.12.
X7 SERIES CAMERA TESTER User Manual
You can long press any app in the all applications list, it will auto move to
shortcut menu . If delete any app in the shortcut menu, please select a app
and press several seconds, it will be deleted.
3.3.3 Screen capture
Long press the key “enter”, can capture screen interface and save it in any
time.
You can go file management to view “file Explorer sdcard-
Pictures–Screenshots”.
3.3.4 Link monitor
Tap icon “Link Monitoring” at left corner on the screen, to enter. It can
detect instrument port rate 10/100/1000M, signal quality detection, upload and
download speed, etc. in real time. It can be used to detect whether the
network video access bandwidth of devices such as NVR is normal.
WWW.RSRTENG.COM
Page.13.
X7 SERIES CAMERA TESTER User Manual
When using a four-core cable to connect to a Gigabit device, would prompt “the
link limited”.
Advanced link monitor It is for monitoring CVBS loop, Ethernet statistics,
error frame statistics, frame length etc.
WWW.RSRTENG.COM
Page.14.
X7 SERIES CAMERA TESTER User Manual
3.3.5 TesterPlay
Mobile screen projection (Only for android version)
The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and
mobile phone connect the same Wi-fi network. Download and install Remote control app to mobile
phone, Tap icon ”
“, select “TesterPlay” app, Click “Start” will create the RTSP URL.
Mobile phone enter “Remote control” app, please click “Auto search IP” to search remote host IP, then click “Play” to display the real-time image and control IPC Tester. If can’t find the IP address, can click “Manually search IP”, and input tester’s rtsp url to remote host IP, such as 192.168.0.186, then click “Play”. Please contract supplier for Remote control APP.
WWW.RSRTENG.COM
Page.15.
X7 SERIES CAMERA TESTER User Manual
PC screen projection: Install VLC player in the PC, turn on the VLC player “Media – Open Network Streaming”, and input the RTSP address of on the top instrument two-dimensional code, click “play” to view the screen real-time projection.
3.3.6 IP discovery
Press IP discovery
, tester auto-scan the whole network segment IP, as well as auto-modify the
tester’s IP to the same network segment with the scanned camera’s IP.
WWW.RSRTENG.COM
Page.16.
X7 SERIES CAMERA TESTER User Manual
Local IP: Tester’s IP address, Tester can auto-modify the tester’s IP to the
same network segment with the scanned camera’s IP Discovery IP: Connected
tester equipment’s IP address. If the camera connected to the tester directly,
tester will display the camera’s IP address, if tester connects to Local Area
Network, it displays the current IP address. Temp IIP: After searching IP
address, the modified tester’s IP address will not be saved, if you do not
select “Temp IP” the modified tester’s IP address will auto-save after
searching. Start: PING function, Click “Start”, can PING camera’s IP Rapid
ONVIF: Rapid ONVIF Quick link NON ONVIF: NON ONVIF Quick link Applicability:
Using IP discovery app, you don’t need to know the first two digits of
camera’s IP address, it can auto-scan the whole network segment IP, and auto-
modify tester’s IP address, greatly improved engineering efficiency .
3.3.7 IPC Test pro
Camera test often need to open multiple apps, “IPC TEST PRO” app, using new
technology and combine multiple functions to one APP, it can increase
efficiency.
WWW.RSRTENG.COM
Page.17.
X7 SERIES CAMERA TESTER User Manual
Application: Support multi-segment IP address scan, can visual display camera
manufacturer, click IP address to play the image. Connect IP camera, can
supply the power to PoE camera. Real-time display network port connection
status. By one key to connect camera test tool, browser can login and
configure camera. Batch activate Hikvision and Dahua cameras.
3.3.8 Rapid ONVIF test
Rapid ONVIF can display 4K H.265/H.264 camera image by tester mainstream, one key to activate Hikvision camera.
Press
enter Rapid ONVIF function, the meter auto scan all ONVIF cameras in different network
segments. It lists cameras name and IP address on the Left of screen. Tester can auto login camera and display camera image. Factory default use admin password to auto login, if you modified the password, then default use the modified password to log in. If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF
WWW.RSRTENG.COM
Page.18.
X7 SERIES CAMERA TESTER User Manual
cameras. It lists the camera name and IP address on the Device List. Tester
can auto login camera and display camera image.
Click the button “Refresh”, tester will scan the ONVIF camera again. Click the
newly displayed ONVIF camera on the “Device List”. The tester will show the IP
camera’s relative information and settings. Activate HIKVISION Camera: When
connected inactivated HIKVISION Camera, tester can auto recognized, and prompt
“The camera have not been activated, activated now?”, click “OK” to start
activate .
WWW.RSRTENG.COM
Page.19.
X7 SERIES CAMERA TESTER User Manual
Pop-up settings menu when click the “ONVIF setting” icon in the upper left
corner.
Cross network scan: After open this function, enter “Setting – IP Settings –
Advanced” to add other network segments IP, Rapid ONVIF function can across
network segments to scan camera’s IP. Auto Login: After open this function,
tester can auto login camera and display camera image. (The login password is
the same with last time, the first time using password is the default password
“admin”) Video transmission protocol: UTP and TCP protocol. Open password
cracker: Cracks password of cameras. View manual: Open Manual. Restore
Defaults settings: Revert “Rapid ONVIF” to default settings. OK: Save the
modified parameters. Click “MENU” icon to open camera setting.
While in the “Live video” menu, click “Video Menu” at the top right of the
image to access the following tools: Snapshot, Record, Photo, Playback, PTZ
and Settings.
WWW.RSRTENG.COM
Page.20.
X7 SERIES CAMERA TESTER User Manual
ONVIF PTZ control: Tap the image in the direction you want the PTZ camera to
move. Tap the left side of the image to move left, right to go right, up to go
up and down to go down. Compatible IP PTZ cameras will rotate accordingly. PTZ
rotation direction is displayed on top left corner of the image.
WWW.RSRTENG.COM
Page.21.
X7 SERIES CAMERA TESTER User Manual
IP camera video settings: Click “Video Set” to enter the IP camera’s encoder
and resolution settings. Make the desired changes and click “OK” to save.
Image setting: Click “Imaging Set” to adjust image brightness, saturation,
contrast, sharpness and backlight compensation mode.
Profiles: Click “profiles”, can view video streaming current configuration files, as well as switch between Major stream and minor stream. Preview pictures: Quickly preview and zoom in or out pictures, automatically and manual refresh.
WWW.RSRTENG.COM
Page.22.
X7 SERIES CAMERA TESTER User Manual
Identification: Click “Identification” to view information of the camera.
Time set: Click “Time set”, Select “Manual set” to set up the time of camera.
Maintenance: For camera software reset or restore to factory settings. User
Set: Modify camera user name, password etc. parameters.
WWW.RSRTENG.COM
Page.23.
X7 SERIES CAMERA TESTER User Manual
Network setting: Click “Network Set” to change the IP address. Some cameras
cannot support change IP address, so there is no change after saving.
Zoom in image: Press the
key to enter the zoom mode. Press it again to exit zoom mode. When
the image is enlarged tap left, right, up or down on the image to move the whole image on the screen
When the image is enlarged, if not operate on touch screen, it can operate by the keyboard, press the
key
to zoon in, press the key
to zoom out, press upward and downward key to move
image.
WWW.RSRTENG.COM
Page.24.
X7 SERIES CAMERA TESTER User Manual
If it is network video input to the tester, as the tester supports resolution
up to 1080p, the input image will be very clear after it is enlarged. This is
greatly helpful for the installers to ensure the IP camera’s video coverage
and decide the IP camera’s install site. Image can only be enlarged on SD mode
(The icon “ONVIF” is SD mode.) Select relative function on the bottom Toolbar
to operate, “Snapshot” , “Record”, “Photos”, “Video playback”, “Storage set”,
“PTZ control” etc. Snapshot: Click bottom “snapshot” to screenshot the image
and store it to SD card. If select manual storage, appears dialog box “Input
Name”, user-defined the files name (by Chinese character, English letter or
digit) to save in SD card, if select “Auto- storage”, the tester auto stores
the files after snapshot. Record: When you click bottom the “Record” icon,
video starts recording. A red recording icon appears on the screen and begins
to flash and a timer appears indicating the time elapsed for the video. Click
on the “Stop” icon to stop recording and save the video file to the SD card.
Playback: Click the “Playback” icon to view saved videos. Double click the video you want to play. Click to return to the last menu.
WWW.RSRTENG.COM
Page.25.
X7 SERIES CAMERA TESTER User Manual
To rename or delete a photo, click and hold on the file until this screen
appears:
OSD Menu: Select OSD and popup the OSD menu. Include time, channel name and other optional items.
After channel selecting, you can edit the channel name, modify the display position, and switch the font size. Select “default location” in “content location” is without modification. Select “Customization” to arbitrarily adjust the channel name and display location. Click “OK” and the effects will appear. Press return key or click any area of the screen to return to the upper layer of the interface.
WWW.RSRTENG.COM
Page.26.
X7 SERIES CAMERA TESTER User Manual
Video files can play in the Video player on the main menu. PTZ Set preset
position: Move the camera to preset position, enter the preset number on the
Bottom right corner to complete position preset. Call the preset position:
Select the preset number on the left, click “Call” to call preset.
WWW.RSRTENG.COM
Page.27.
X7 SERIES CAMERA TESTER User Manual
PTZ Speed set: Horizontal and Vertical Speed set.
RTSP: Get RTSP address of the current camera Doc: Auto generate test reports
document of camera, click “generate document”. Click Preview to view the
report document.
WWW.RSRTENG.COM
Page.28.
X7 SERIES CAMERA TESTER User Manual
Enter the camera test information, click “Generate Document” to complete the
report.
Click “Doc” menu again, you can preview the report document.
Icons description: The description of function icons on the bottom toolbar.
WWW.RSRTENG.COM
Page.29.
X7 SERIES CAMERA TESTER User Manual
3.3.9 Non ONVIF
Display image from the 4K H.265 camera by mainstream
Click icon
to enter IP camera test
Note: Currently, the IPC Test App only supports some brands’ specific IP cameras, these include specific models made by ACTI, AXIS, Dahua, Hikvision, Samsung, and many more. If the camera is not fully integrated, please use the ONVIF or RTSP apps. IPC test interface
Local IP: This is the tester’s IP address. Click “Edit” to enter “IP setting”
and change the tester’s IP address settings. IP camera type: Click on the IP
Camera type to select the Manufacturer and model number of the integrated IP
camera.
“Manual”: Click IP camera type, list Honeywell, Kodak, Tiandy, Aipu-waton,
ACTi IP camera etc. If the brand has offered official original protocols,
please select camera type, input IP camera address, user name and password,
click “official” to enter the camera image display interface(Currently, only
support DAHUA official protocols )
WWW.RSRTENG.COM
Page.30.
X7 SERIES CAMERA TESTER User Manual
Stream code: When test camera via RTSP, you can select mainstream or sub stream to test (if camera’s RTSP have not been start or without, it will tip “auto match fail, please switch to manually selecting”.
IP Camera’s IP: Enter the IP camera’s IP address manually or click “Search” to auto-scan for the IP camera’s IP address. It is better to directly connect the IP camera to the tester so the search results will only display the camera’s IP address. If the tester is connected to a PoE switch, it will find and display several IP address.
WWW.RSRTENG.COM
Page.31.
X7 SERIES CAMERA TESTER User Manual
IPC User Name: Enter IP camera’s user name. IPC Password: Enter IP camera’s
login password. IPC Port: When you select the IP camera type, it will default
the camera’s port number and doesn’t need to be changed. After all settings
are completed, click “Enter” to view the live video.
If IP address setting has error or IP camera is not connected.. The tester prompts “Network Error”
Click
to quit from image display and return to IP camera test interface.
Once you are viewing video on the IPC Test app, you will see the “Video Menu” icon on the top right. This button will give you access to Snapshot, Record, Photo, Playback, PTZ, and Set. Please refer to the ONVIF section to use these functions.
3.3.10 HDMI input
HDMI in HD signal test, Tap icon ”
“to enter
When tester receives HDMI in image, the top tool bar shows the resolution of this image. You can
select “resolution” to set resolution in the setting menu. Tap screen by twice, full image display.
Support resolution up to 4K 3840x2160P 30fps.
720×480p /720×576p /1280×720p /1920×1080p /1024×768p/1280×1024p /1280×900p /1440×900p
WWW.RSRTENG.COM
Page.32.
X7 SERIES CAMERA TESTER User Manual
(1) Snapshot Click the icon “Snapshot”, when the video in, to take a picture and save the current video frame in the SD card as JPEG file. If the unit is set to the manual mode an “Input Name” pop up box will appear and you can enter a title for the snapshot. If the unit is set up to automatically set file names, this box will not pop up.
(2) Video record When you click the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the “Record” icon again to stop recording and save the video file to the SD card.
WWW.RSRTENG.COM
Page.33.
X7 SERIES CAMERA TESTER User Manual
If select manual storage, before recording begins, appears dialog box “Input
Name”, user-defined the files name(by Chinese character, English letter or
digit) to store in SD card, tester will hereby store the files in SD card
after recording. If select “Auto-storage”, tester will auto store the files in
SD card after recording.
(3)Photo Click the icon “photo” to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears
Click
to close and return to PTZ controller.
WWW.RSRTENG.COM
Page.34.
X7 SERIES CAMERA TESTER User Manual
(4) Recorded video playback Click the “Playback” icon to view your recorded
videos. Tap on the video file image you want to watch. To rename or delete a
video, click and hold on the file until this screen appears:
Video files also can play in the main menu “Video Player”.
3.3.11 Analog camera test
Analog camera test and PTZ control, click icon
to enter
Display the input video image, click the top menu bar icon (PEAK level, SYNC level, COLOR BURST measurement)
to enter video level meter,
WWW.RSRTENG.COM
Page.35.
X7 SERIES CAMERA TESTER User Manual
Select relative function on the right side Toolbar to operate, functions including “Photos”, “Snapshot” ,
“Record”, “Playback”, “PTZ”, “Set”.
Click
, or press
to quit.
Click the screen twice quickly, can be full zoom in on the touch screen.
- PTZ controller parameter setting
Select and click icon “PTZ”, to enter PTZ setting:
A. Protocol Use the up and down arrow keys to move the yellow cursor to the “protocol”, set corresponding Protocol and support more than thirty PTZ protocols. Such as Pelco-D, Samsung, Yaan, LiLin, CSR600, Panasonic, Sony-EVI etc. B. Port Click and move to “port” Select the communication port for the PTZ camera controlling (RS485) C. Baud Move the yellow cursor to “Baud “, Select the baud rate according to baud rate of the PTZ camera.(150/300/600/1200/2400/4800/9600/19200/57600/115200) D. Address Set the ID according the ID of PTZ camera (0~254), the setting address data must be consistent the speed dome address.
WWW.RSRTENG.COM
Page.36.
X7 SERIES CAMERA TESTER User Manual
E. Pan speed Set the pan speed of PTZ camera (0~63) F. Tilt speed Set the tilt
speed of PTZ camera (0~63) G. Set preset position (Set PS) Click and select
“Set PS”, set and save preset position number(1~128). H. Call the preset
position (Go PS) Click and select “Set PS”, set and save preset position
number (1~128), click “sure” to save, Call some special preset number, can
call the dome camera menu
Check and set the protocols, address, interface and baud, all must be
consistent with the dome camera, then the IPC tester can test. After setting
the parameter, the tester can control the PTZ and lens To control PTZ by
screen touch: Tap left, right, upward and downward on the touch screen to
control the PTZ rotation direction. By two fingers move outward and inward on
the touch screen to zoom in and out the PTZ.
PTZ Control:
Press the key
control the PTZ direction of rotation
Press the key
or
, switch on or turn off the aperture.
Press the key
or
, adjust the focus manually
Press the key
or
, manually adjust the zoom
- Video and storage setting
Click icon “set”, to enter and set analog video image brightness, contrast, color saturation, as well as the
WWW.RSRTENG.COM
Page.37.
X7 SERIES CAMERA TESTER User Manual
file storage way after snapshot and recording, support auto-storage and manual
storage. When select manual storage, user can name and store the files.
- 4 x zoom image display and Video out
When image input, press
to enter “zoom”, press it again to quit.
Using the touch screen to control PTZ camera movement:
Tap left, right, upward or downward on the video image to move the PTZ camera in a desired direction.
Stretch two fingers outward or inward on the touch screen to zoom the image in or out.
If not use touch screen to operate, press the key
to zoom out, press the key
in, press upward and downward key to move the image.
to zoom
WWW.RSRTENG.COM
Page.38.
X7 SERIES CAMERA TESTER User Manual
For analog video input, as the resolution is 720480, it is normal that the
zoom in image is not clear. But for network digital video input, as it
supports resolution up to 1280960, the zoom in image is still very clear.
This is very helpful for IP camera installation. 4) Snapshot Click the icon
“Snapshot “, when the video in, to take a picture and save the current video
frame in the SD card as JPEG file. If the unit is set to the manual mode an
“Input Name” pop up box will appear and you can enter a title for the
snapshot. If the unit is set up to automatically set file names, this box will
not pop up.
- Video record When you click the “Record” icon, video starts recording. A red recording icon appears on the screen and begins to flash and a timer appears indicating the time elapsed for the video. Click on the “Record” icon again to stop recording and save the video file to the SD card. if select manual storage, before recording begins, appears dialog box “Input Name”, user-defined the files name(by Chinese character, English letter, or digit) to store in SD card, tester will hereby store the files in SD card after recording. If select “Auto-storage”, tester will auto store the files in SD card after recording.
WWW.RSRTENG.COM
Page.39.
X7 SERIES CAMERA TESTER User Manual
(6)Photo Click the icon “photo” to enter, click the selected thumbnail photo to display it on the screen. Double-tap the image you want to view to make it full screen. Double-click again the photo to return. To rename or delete an image, click and hold on the file until this screen below appears.
Click
to close and return to PTZ controller.
WWW.RSRTENG.COM
Page.40.
X7 SERIES CAMERA TESTER User Manual
(7) Recorded video playback Click the “Playback” icon to view your recorded
videos. Tap on the video file image you want to watch. To rename or delete a
video, click and hold on the file until this screen appears:
Video files also can play in the main menu “Video Player”. (8) Video level meter
Click the icon
to enter, the IP camera tester has adopted hardware high-speed sampling and
processing technology, can perform both NTSC and PAL video amplitude signal measurements for
PEAK to PEAK, SYNC levels and COLOR BURST chroma level. When an analog signal is fed into
the meter, the tester displays the measurements on the bottom left corner of the screen
WWW.RSRTENG.COM
Page.41.
X7 SERIES CAMERA TESTER User Manual
While in PAL format, the unit will be mV, While in NTSC format, it will be
IRE.
Video signal level
140±15IRE
NTSC
Chroma level( COLOR BURST)
40±5IRE
SYNC signal level
40±5IRE
Video signal level
1000±200mV
PAL
Chroma level( COLOR BURST)
300±35mV
SYNC signal level
300±35mV
Video signal PEAK to PEAK level:
For NTSC format, the video signal level is 140±15IRE
For PAL format, the video signal level is 1000±200mV
If the level is too low, it will cause the image to lose quality and limit the distance it will travel over
cable. If the level is too high, it will distort the image.
SYNC level: Tests the amplitude of the video sync pulse to verify if the video level is correct.
For NTSC format, the SYNC level is 40 ± 5IRE
For PAL format, the SYNC level is 300 ± 35mV
If the level is too low, it will cause the image to not frame out properly. If the level is too high, it will
lead to a poor quality image.
COLOR BURST level: Testing the color burst level will determine if the burst signal is sufficient to
trigger the displays color producing circuit. Burst will diminish in amplitude over longer cable runs and
can get fall below the threshold for the video display to show a color image.
WWW.RSRTENG.COM
Page.42.
X7 SERIES CAMERA TESTER User Manual
For NTSC format, the Chroma standard level is 40 IRE For PAL format, the
Chroma standard level is 280mV If the Chroma level is too low, the color will
not be as deep, and some details of the image will become lighter. If the
Chroma level is too high, there will be distortions on the image. If the
coaxial cable is too long, it will reduce the chroma level. CVBS image loop
test: Test video optical transmitter and receiver and video cable, connect one
end to the tester “VIDEO OUT” port, and the other end connected to “VIDEO IN”
port, the signal send via “VIDEO OUT” port, and received via “VIDEO IN” port,
If the testing is ok, the tester displays several gradually dwindling photos
on the desktop.
3.3.12 CVBS color-bar generator (TV OUT)
Click
to enter, the tester sends the color bars from the “Video out” port, Click the icon “PAL”,
select “PAL/NTSC” output formats.
Click the selected color-bars, testing image or single bar (red, green, blue, white or black). Double click to full display on the screen and output, click to return main menu. Application BNC loop test: Tester can send and receive color bar generator through the tester’s “video out and video in” port, it is for testing transmission channels, such as video Optical, video cables etc. The tester
WWW.RSRTENG.COM
Page.43.
X7 SERIES CAMERA TESTER User Manual
“VIDEO OUT” port to connect optical terminal’s sending port, and “VIDEO IN”
port to optical terminal’s connect its receiving port. A. When maintaining the
dome camera, the tester sends out the color bar by its BNC output to the
monitor at the monitoring center. If the monitor receive the color bar, it
means the video transmit channel works normally. Meanwhile on the basis of the
received color bar, the monitoring center can judge if transmission has loss
or interference. B. The tester sends out the pure color bar (such as white and
black color), to test the monitor whether
has bright or black dots C. The tester sends out video signal image to test if
the image received by the monitor has excursion.
3.3.13 AutoHD (only for X7-MOVTADHS, X7-ADHS, X7-ADH)
Auto-recognize the resolution and Auto-display the image of the connected
camera. Support coaxial PT Z control and call OSD menu, support up to 8MP
TVI/CVI/AHD/SDI cameras.
3.3.14 HD Coaxial & Analog level test* (only for X7-MOVTADHS)
Through hardware high-speed sampling and processing technology, accurately
measure video peak level, sync level and burst level. It is used for level
measurement of HD coaxial cameras, judge whether the working image of the
camera and the image after attenuation by BNC cable transmission are normal,
quickly detect and eliminate faults.
WWW.RSRTENG.COM
Page.44.
X7 SERIES CAMERA TESTER User Manual
Image display: Select the camera type, no need to select the resolution, click the camera icon, can browse the camera image directly. Level Meter Test: Need to select the camera type and resolution, click “test” to test the level Color bar generation: Click “CVBS”, quickly enter color bar generation app Test ResultThe percentage and signal grid of the level value. Compared with the reference value. When the value is lower than the threshold, the background color will be grayed and appear the warning icon. Different camera and cable lengths, different level value. Reference value: The normal value at this resolution, it is used to reference and compare test results, click “value” to modify. Threshold: Critical value at this resolution. Lower this value, will appear image noise on the screen, click “value” to modify. Reset: Click “Reset” to reset the reference value and threshold. Create documents: The testing report can save customer information, level meter test information, camera information and Instrument information.
WWW.RSRTENG.COM
Page.45.
X7 SERIES CAMERA TESTER User Manual
WWW.RSRTENG.COM
Page.46.
X7 SERIES CAMERA TESTER User Manual
3.3.15 SDI Camera Test* (Only for X7-MOVTADHS, X7-ADHS)
SDI camera test, Dome camera test and PTZ control, click icon
to enter.
When tester receives SDI camera image, it will display the image data.
Double-taps on the screen to make the image displayed full screen.
The tester supports resolution as follows:
1280x720P 25Hz, 1280x720P 30Hz, 1280x720P 50Hz, 1280x720P 60Hz, 1920x1080P 25Hz
1920x1080P 30Hz, 1920x1080I 50Hz, 1920x1080I 60Hz, EX-SDI: 2560x1440P /25/30FPS,
3840×2160 25/30FPS.
IPC tester’s HDMI output port can be use as SDI to HDMI converter, output HD SDI image to HD TV
monitor.
Select relative function on the right side Toolbar to operate, “Snapshot” , “Record”, “Photos “,
“Video playback”, “PTZ control”, “Video Brightness and Storage set”, the operation is the same to the
video monitor function, please refer to the relevant instructions “3.3.1” in the manual.
Click
or press
to quit.
3.3.16 CVI camera test* (Only for X7-MOVTADHS, X7-ADHS, X7-ADH)
HD CVI camera, CVI dome camera test and PTZ control, click icon
to enter
When HD CVI signal input, the tester will display the image resolution on the top bar. Double-taps on
the screen to make the image displayed full screen.
WWW.RSRTENG.COM
Page.47.
X7 SERIES CAMERA TESTER User Manual
The tester supports resolution as follows: 1280x720P 25FPS / 1280x720P 30FPS /
1280x720P 50FPS / 1280x720P 60FPS / 1920x1080P 25FPS / 1920x1080P
30FPS/2560x1440P 25FPS/2560x1440P 30FPS/ 2592x1944P 20FPS / 2960x1920P 20FPS /
3840 x 2160P 12.5/15 FPS
(1) PTZ control 1.1 Coaxial PTZ control Click the icon “PTZ” on the right
toolbar to do the corresponding setting. “Port”: select coaxial control
WWW.RSRTENG.COM
Page.48.
X7 SERIES CAMERA TESTER User Manual
Enter PTZ address to perform parameters setting
Operation instructions, please refer to “3.3.1 PTZ (1) Video monitor test” The
PTZ address in the tester must be consistent with the dome camera or decoder,
then the IPC
tester can test. After setting the parameter, the tester can control the PTZ
and lens.
To control PTZ by screen touch: Tap left, right, upward and downward on the touch screen to control the PTZ rotation direction, PTZ cameras will rotate accordingly. By two fingers move outward and inward on the touch screen to zoom in and out the PTZ.
WWW.RSRTENG.COM
Page.49.
X7 SERIES CAMERA TESTER User Manual
To control PTZ by key buttons Press arrow keys to control rotation Press the key Press the key Press the key
to control the PTZ direction of
to switch on or turn off the aperture. to adjust the focus manually. to
manually adjust the zoom.
Set preset position Setup preset position, move the PTZ camera to the preset position, the Tap it and input preset position number. Tap “Set position” to complete set preset position.
Call preset position Tap the preset position: Tap the preset position area, input preset position number. Tap “call position” to complete call preset position.
WWW.RSRTENG.COM
Page.50.
X7 SERIES CAMERA TESTER User Manual
1.2 RS485 control
Operation instructions, please refer to “3.3.1 PTZ (1) PTZ control parameters setting”.
WWW.RSRTENG.COM
Page.51.
X7 SERIES CAMERA TESTER User Manual
(2) Coaxial camera menu setting Tap icon “UTC”, select “menu setting” to enter
the dome camera menu.
Input calling dome camera menu address code, after finishing the parameter settings, you can press the
key
or click the icon
to call the dome camera menu.
WWW.RSRTENG.COM
Page.52.
Press arrow keys
X7 SERIES CAMERA TESTER User Manual
to set
(3) Snapshot, record, photo viewer and video play back, please refer to “3.3.1 PTZ (1) Video
monitor test”.
Tap “close menu” or press the key ”
” to close camera menu.
WWW.RSRTENG.COM
Page.53.
X7 SERIES CAMERA TESTER User Manual
(4) Save setting Click icon “Set” on the right toolbar to enter storage
setting. Support auto-storage and manual storage. When select manual storage,
user can name and store the files.
3.3.17 TVI camera test* (Only for X7-MOVTADHS, X7-ADHS, X7-ADH)
HD TVI camera, TVI dome camera test and PTZ control, Click icon
to enter
The tester supports resolution as follows:
1280x720P 25,30,50,60fps / 1920x1080P 25,30,50,60fps / 2048x1536P 18,25,30fps
/ 2560x1440P 15,25,30fps / 2688x1520Pfps / 2592x1944P 12.5,20fps / 3840x2160P
12.5,15fps
WWW.RSRTENG.COM
Page.54.
X7 SERIES CAMERA TESTER User Manual
Coaxial camera menu settings
Tap icon “UTC”, select “menu setting” to enter the dome camera menu.
Input calling dome camera menu address code, after finishing the parameter settings, you can press the
key
or click the icon
to call the dome camera menu.
More operation instructions (such as PTZ control, coaxial camera menu setting, snapshot, recording and playback etc.), please refer to “3.3.6 CVI camera test”.
WWW.RSRTENG.COM
Page.55.
X7 SERIES CAMERA TESTER User Manual
3.3.18 AHD camera test* (Only for X7-MOVTADHS, X7-ADHS, X7-ADH)
AHD camera, AHD dome camera test and PTZ control, Click icon
to enter
The tester supports resolution as follows:
1280x720P 25,30FPS / 1920x1080P 25,30FPS / 2048x1536P 18,25,30FPS / 2560x1440P
15,25,30 FPS / 2592x1944P 12.5,20FPS / 3840 x 2160P 15FPS
Coaxial PTZ control UTC control: select “PTZ control or PTZ control-2” (AHD camera has two different order, if select “PTZ” cannot control, please go “PTZ-2”)
If to coaxial PTZ control the AHD camera, no parameters setting is needed. More operation instructions please refer to “3.3.6 CVI camera test”
WWW.RSRTENG.COM
Page.56.
X7 SERIES CAMERA TESTER User Manual 3.3.19 NET TOOL PRO
NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection,
PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP.
(1) IP address scan
Connect the cable to the LAN port. Set your IP address search range by
changing the Start and End IP addresses. Click the “Start” button to scan the
IP address range. You can also input an IP address in the Port Number Scan to
scan for open ports.
WWW.RSRTENG.COM
Page.57.
X7 SERIES CAMERA TESTER User Manual
(2) PING Test
PING is the most conventional network debugging tool, it is used for testing if the connected IP camera
or other network equipment’s Ethernet port is working normally and the IP address is correct.
Connect a network cable to the LAN port and click the
icon to open the PING tool. You can set
your LOCAL (native) IP address, Remote IP address (e.g. IP camera), Packet count, Packet Size, Packet
time and Timeout. Press “Start” to start pinging. If the IP camera or network device is not configured
properly or not plugged in, it will say “Destination host unreachable” or “have 100% packet loss”. If the
tester connects to the device, the send and receive packets will have a 0% packet loss.
Application: PING testing is the most conventional network debugging tools. It is used for testing if the connected IP camera or other network equipment’s Ethernet port is working normally and the IP address is correct. It’s normal that the first data packet will be lost when test start.
Network test (Ethernet bandwidth test)
To use the Network tester, you will need two IP testers. One is used as a Server and the other as a Client.
Both devices must be on the same network segment in order to communicate. Click the
icon to
open the Network Tester app.
WWW.RSRTENG.COM
Page.58.
X7 SERIES CAMERA TESTER User Manual
When test, need a tester or a computer installed Network Test Software as the
Server, the other tester sends packet test. The two testers must be in the
same network segment. a). Start the server: Click “Start Server” button to use
the tester as a Server. It will display its IP address at the top of the
screen.
WWW.RSRTENG.COM
Page.59.
X7 SERIES CAMERA TESTER User Manual
b). Start send packet test: Using the other IP tester, type in the Server’s IP
address at the top right corner of the screen. This app is used to send
packets for network speed testing. Click the “Start” button to send the
packets and start testing.
Network bandwidth testing can also be tested with a computer using compatible
network bandwidth testing software. Install network bandwidth testing software
on a computer, as a test Client or Server, to do the mutual testing with the
tester. If use computer as the server, the computer IP address is:
192.168.0.39
WWW.RSRTENG.COM
Page.60.
X7 SERIES CAMERA TESTER User Manual
Tester as Client, tester’s IP address is: 192.168.0.238. The Server and the
Client are at the same network segment, but with different IP address. Input
Server’s IP address 192.168.0.39 in the tester and click “Start” to test
network bandwidth. Or use tester as a Server, computer as test Clientselect
Client, input tester’s IP address to test
When use tester as Server, shows results:
(3) Port Flashing
Connect a network cable to the meter’s “LAN” port, click the icon
to open the Port Flashing app.
Click “Start”. The IP tester sends a unique signal to make the connected LAN port of the switch flash.
If the tester and PoE switch are connected well, the LAN port of POE switch flash at special frequency,
if not, no any changes on the LAN port
WWW.RSRTENG.COM
Page.61.
X7 SERIES CAMERA TESTER User Manual
Application: The tester will send special signals to make the connected LAN
port flicker at special frequency, which will enable the installers to easily
and quickly find the connected Ethernet cable. This function can prevent
mistakenly insertion or disconnection non-corresponding cable to artificially
interrupt network connection.
(4) DHCP server
Click on the DHCP icon to open the DHCP server app. Select the “Start” check
box at the top and make any desired changes to the network settings. Click
“Save” to start assigning dynamic IP addresses for IP cameras and other
networked devices. Click the “Refresh” button to check your Client list.
WWW.RSRTENG.COM
Page.62.
X7 SERIES CAMERA TESTER User Manual
(5) Trace route
It is used to determine path of the IP packet access target.
Note: Trace route testing results only for reference, for accurate test route tracking, Please use
professional Ethernet tester.
Click
to enter trace route
Input tracking IP address or domain name in the Remote Host IP. Set maximum hop count, normally
default is 30
Click “start” to trace the goal address
(6) Link monitor
Click the
icon to open the Link Monitor app. This app is used to see if an IP address is occupied
by other network devices. This will avoid new address conflicts
Click “Add” and enter the desired IP address. To test different network segments, click the “Settings”
icon on the main menu and go to IP Settings and make the desired changes. Once the desired IP
addresses are added to the Link Monitor list, click “Start”. If the IP address status shows a check mark
the IP address is occupied. If the IP address status shows an X the IP address is available. Click “Stop”
to stop the testing
WWW.RSRTENG.COM
Page.63.
X7 SERIES CAMERA TESTER User Manual
Application: Add an IP camera or other network device to the current network group, the new IP address must not be occupied, otherwise it will cause IP conflicts and stop the equipment normal working. Link monitor can check if the new setting IP address is occupied.
3.3.20 PoE power / DC12V 3A and DC 5V 2A USB power output
When the tester is turned on, the DC 12V and DC 5V power output functions are automatically turned
on. If the IP tester is turned off, the DC 5V USB can still be used to power an external USB device.
To use the PoE Power Output function, click on the icon
and change the switch “ON” or “OFF”.
The IP camera needs to be connected to the LAN port before you turn PoE Power on. If the IP camera
Supports PoE, the PoE power is delivered via pins 1, 2, 3 and 6 on the LAN port. The IP tester will
display “48V ON” at the top of the screen when the POE power is still on.
WWW.RSRTENG.COM
Page.64.
X7 SERIES CAMERA TESTER User Manual
Note: 1. Don’t input power into the “DC12/3A OUTPUT” port. 2. Don’t output
this DC12V/3A power to the DC12V/IN port of the IP camera tester to avoid
destroy 3. The IPC tester power output is close to 3A, if the IP camera’s
power is over 3A, the tester will auto enter protection mode. Disconnect all
the connections of the tester and then connect the tester with power adaptor
to resume the tester. 4. Before turning on the PoE power output, please make
sure the IP camera supports PoE power. Otherwise it may damage the IP camera.
5. Make sure you plug in your IP camera to the LAN port prior to turning on
PoE power 6. Make sure the tester is full charged or more than 80% charged,
otherwise the tester will shows “low power”, “not able to supply power”.
3.3.21 DC 24V 2A power output
The top and the bottom of the “DC24V ON/0W “is power output interface
Application: Power output function is mainly used in the camera field demonstration and testing, meanwhile, for some camera installation sites, if no power outlet, tester can offer temporary power for the camera.
WWW.RSRTENG.COM
Page.65.
X7 SERIES CAMERA TESTER User Manual
Note:
a. Don’t input any power into the “DC24V/2A OUTPUT” port of the tester to
avoid destroy. Man-made damage is not within our company’s warranty b. Don’t
output this DC24V/2A power to DC12V/ IN port to avoid destroy. Otherwise the
tester will damage, and man-made damage is not within our company’s warranty.
c. The IPC tester power output is close to 2A, if the IP camera’s power is
over 2A, the tester will auto enter protection mode. Disconnect all the
connections of the tester and then connect the tester with power adaptor to
resume the tester. d. Make sure the tester is full charged or more than 80%
charged, otherwise the tester will shows “low power”, “not able to supply
power”
3.3.22 Cable Test
Click icon
to enter
Test LAN cable or telephone cable. Connect LAN cable or telephone cable with the CCTV tester and cable tester. And then the connecting status, cable type and the sequence of wires as well as the serial number of the cable tester kit will be displayed.
WWW.RSRTENG.COM
Page.66.
X7 SERIES CAMERA TESTER User Manual
The number of the cable tester is 255. If need several different number other
types cable testers, should pay the additional cost. Cable test Tap “cable
test sketch map”, pop up Straight-through cable and crossover cable sketch, It
is for line sequence reference, when the crystal on the first pressure in the
twisted-pair.
3.3.23 RJ45 cable TDR test
Connect cable to tester’s LAN port, click icon ”
” to enter RJ45 cable TDR test app.
WWW.RSRTENG.COM
Page.67.
X7 SERIES CAMERA TESTER User Manual
Single test: Test cable status, length and attenuation. Repeat test: Continue
to test cable status, length and attenuation. Status: After link up, screen
display “online”, if not link up or open circuit, screen display “open
circuit”, if cable pair is short circuit, screen display “short circuit”.
Length: The max test length is 180 meters, when cable is open circuit or short
circuit, can test the cable length, if screen display “online”, the testing
result would be not accurate. Cable quality test: Green is good quality cable,
Yellow is Poor quality cable, Red is water poured cable, the attenuation value
will be displayed when cable over 10 meters.
Advanced Test: Test cable pair status, length, attenuation, reflectivity, impedance, skew and other parameters. Attenuation reflectivity: After link up, if reflectivity value is 0, it is the best quality communication Impedance: After link up, if the impedance value is 100, it is the best quality communication, the range is generally in 85-135. Skew: After 1000M link up, when skew value is 0ns, it is the best quality communication, if over 50ns, will cause a Bit Error Rate in the transmission. Cable sequence diagram: A straight- through and cross-over cable diagram, the cable sequence display for reference.
WWW.RSRTENG.COM
Page.68.
X7 SERIES CAMERA TESTER User Manual
Click “Help” to check the instruction of all parameters.
WWW.RSRTENG.COM
Page.69.
X7 SERIES CAMERA TESTER User Manual
3.3.24 Cable Tracer
Connect tested cable or BNC cable to the UTP port or the SCAN (video out BNC port) BNC port on the
bottom. Click icon
to enter, click the Number on the screen to adjust audio type.
UTP mode is used for searching the normal network cable or other cables. STP mode is used for searching the shielded network cable. Rotating the switch of cable tracer to turn on. Clockwise rotation increases sensitivity, anticlockwise rotation reduce sensitivity. Cable tracer and Cable tester can be tested at the same time. It is better to judge whether the search network cable is accurate. Connect the other end of the tested network cable to the “UTP” port of cable tracer, the cable sequence, continuity, test box number and network cable type will be displayed on the right side of the meter interface. The “G” indicates the continuity of the shielded network cable. The 1-8 indicators of cable tracer will flash according to the cable sequence. The DIRECT / CROSS / OTHER three indicator lights display the type of network cable directly. Press the “MUTE” button of cable tracer for 2 seconds. After the “Di” sound, the silent mode is turned on. In the silent mode, can judge cable type according to the indicator light. Press the “MUTE” button again to exit the silent mode.
WWW.RSRTENG.COM
Page.70.
X7 SERIES CAMERA TESTER User Manual
Application It’s convenient for people to find out the other end of the cable
from the messy cables in security maintenance and network engineering. While
searching BNC cable, connect one port of the alligator clips to the copper
core or copper net of the BNC cable, the other one to connect the earth wire
(barred windows).
Note: The battery of the cable tracer must according to corresponding positive
pole + and negative pole -, otherwise will damage the tester.
Note: While the cable tracer tester is receiving the audio signal from the
tester, it may be influenced by other signals and make some noise.
3.3.25 TDR cable test* (Only for X7-MOVTADHS)
Note: The testing cable can’t be connected to any equipment, otherwise it will
damage the tester. Connect Alligator clip cable to the TDR port, and the cable
must connect well before testing, otherwise it will influence the accuracy.
Built-in BNC cable, network cable, RVV control cable, Telephone line and TVVB
cable etc can test. 11 groups user-defined cable can be set.
WWW.RSRTENG.COM
Page.71.
X7 SERIES CAMERA TESTER User Manual
(1) Curved trajectory 1) Curve result analysis Inflection point: The position
of break point or short-circuit of the cable, is where curve suddenly rises or
falls after the smooth curve. Short circuit: The curve shows an upward trend
after the inflection point Open (break point): The curve shows a downward
trend after the inflection point 2) Curve operation Zoom: Zoom the curve.
Click icon “zoom”, tap the curves by two fingers or use virtual keyboard (tap
the icon of the screen left edge, to call virtual keyboard) Move: Move curve,
click icon “move”, and drag the curve to move.
Distance bar: Display the current length, and use the virtual keyboard to move distance bar. Curve thumbnail: Double-click the thumbnail, to restore the scaled curve (2) Calibration Due to differences in production processes and materials, the cable impedance of different manufacturers may be different, which will lead to large deviations in the test results. The Calibration function can be used at this time. Click “Cable” “Type” to select cable and start testing. One tap on “Start”, do one testing. If select built in cable type for testing, click “+” and “-” to adjust cable’s wave speed.
WWW.RSRTENG.COM
Page.72.
X7 SERIES CAMERA TESTER User Manual
User-defined calibration: Choose the cable 100 meters to 200 meters (more than
50 meters), click “Cable”, “Type” to select user-defined 1 for calibration, 11
groups user-defined can be set.
1. Select user-defined and click “Calibration” to enter test, click “user- defined 1” can define cable name, such as: AiPu BNC-5 2. Click “Cable”, “Type” to select cable, and corresponding type, for example, if testing BNC cable, select “BNC”, if testing communication cable 75-2, select SYV 75-2.
WWW.RSRTENG.COM
Page.73.
X7 SERIES CAMERA TESTER User Manual
3. Click “+” or “-” to adjust wave speed, while display length is the same
with the actual Length, click “Save” to save calibration data. It can be used
for the same cable testing next time.
Application: TDR test is the use of pulse reflection method, to transmit pulse
signal for tested cable, when cable is open circuit or short-circuit,
reflected pulse is generated, the tester receives and deals with the reflected
wave, measurement results displayed on the screen. TDR can test cable open
circuit and short circuit, help engineer quickly find the cable’s problem
location. It is more convenient and efficient to repair the faulty cable.
Note: The TDR reflect signal could be affected by the cable quality cable’s
not well connected etc to cause the different TDR measurement. The TDR
measurement is for reference only.
3.3.26 BNC attenuation test* (Only for X7-MOVTADHS)
Introduction: Through hardware high-speed sampling and processing technology,
the coaxial cable transmission attenuation value can be tested in real time,
which can be used to detect the attenuation of the coaxial cable through long-
distance transmission and the attenuation value of different cables but at the
same distance, and can detect the quality of coaxial cable.
WWW.RSRTENG.COM
Page.74.
X7 SERIES CAMERA TESTER User Manual
Test Methods: 1.Connect the two alligator clip cables to the CVBS IN port and
CVBS OUT port separately. Two crocodile clips red to red and black to black
clip together, then click “calibration” to calibrate it.
2.After calibration, the red clip clips the copper core of the BNC cable, and the black clip clips the outer envelope of the BNC cable. attenuation value will be displayed after connection, as below:
3.Click “Reset”, the application will restore factory defaults.
WWW.RSRTENG.COM
Page.75.
X7 SERIES CAMERA TESTER User Manual
3.3.27 PoE Voltage test
Click icon
to enter PoE voltage measurement
Connect a network cable from a PoE switch to the IP tester’s PSE IN port.
Connect an IP camera or other PoE using node to IP tester’s LAN port, the PoE
voltage and the cable’s pin connection status show on the screen.
Note: This test if for measuring the voltage being drawn by the PoE node and
the IP tester must be between the PoE switch and the PoE node for this test to
work.
Note: The PoE switch must be connected to the PSE IN port. The powered device
such as IP camera or other PoE node must be connected to the LAN port.
Note: Do not connect PoE power supply equipment (such as a PoE switch) to the
tester’s UTP/SCAN port, otherwise it will damage the tester. PSE transmission
When PoE / PSE voltage testing, PoE/PSE contact to the tester’s PSE “IN” port,
the camera connect to tester’s LAN port, tester not only can transmit voltage
to supply power for camera, but also transmit data at the same time. As well
as the computer connect to the PoE/PSE, it can log in connected tester’s PoE
camera.
3.3.28 12V power input test
Connect 12V power adaptor to tester’s charging port, then click icon “PoE” to
enter voltage
WWW.RSRTENG.COM
Page.76.
X7 SERIES CAMERA TESTER User Manual
measurement app, screen show the current adaptor input voltage and power.
Note: the current 12V input measured power is the battery charging power and
the device working power, the measured power will change depending on the
different of battery power and backlight brightness.
Warning: Not allow connect device with input power over 17V to tester “12V IN” port, otherwise it will damage the machine.
3.3.29 Digital Multi-meter* (Only for X7-MOVTADHS)
Click icon
to enter.
WWW.RSRTENG.COM
Page.77.
- SYMBOLS: U: DC Voltage Measuring : Resistance Measuring
~ U: AC Voltage Measuring
: Continuity Testing
X7 SERIES CAMERA TESTER User Manual
A: DC Current Measuring : Diode Testing
~ A: AC Current Measuring : Capacitance Measuring
AC/DC Auto- range
Voltage and current measurement state display The Multi-meter auto adjust the range by input signal or tested components
Data hold
Hold data
Relative
Display the relative measurement value
measurement Press the key to change display state
10A socket In 10A current measurement state ,indicate use 10A socket
Over range
The current measurement value over the range, if in the Auto range state, to switch Auto.
- OPERATING INSTRUCTION
A. DC Voltage Measuring
WARNING! You can’t input the voltage which more than 660V DC, it’s possible to show higher voltage, but it’s may destroy the inner circuit. Pay attention not to get an electric shock when measuring high voltage.
a. Connect the black test lead to the “COM” jack and the red test lead to the
“V/” jack.
b. Select U, enter the DC voltage measurement.
c. the tester default Auto range status ,by click “DC auto range”, press the
key can select manual range and restore auto range .
WWW.RSRTENG.COM
Page.78.
X7 SERIES CAMERA TESTER User Manual
Manual range: 0.000V 6.600V range 00.00V 66.00V range 000.0V 660.0V range
000.0mV 660.0mV rang B. AC Voltage Measuring
WARNING! You can’t input the voltage which more than 660V AC, it’s possible to
show higher voltage, but it’s may destroy the inner circuit. Pay attention not
to get an electric shock when measuring high voltage.
a. Connect the black test lead to the “COM” jack and the red test lead to the
“V/” jack. b. Select U~ , enter the AC voltage measurement. c. The tester
default Auto range status, by click “AC auto range” d. Manual range can be
select, press the key “NEAR” to restore Auto range e. Manual range: 0.000V
6.600V range
00.00V 66.00V range 000.0V 660.0V range 000.0mV 660.0mV range
C. DC Current Measuring (only manual range)
WARNING! Shut down the power of the tested circuit, and then connect the meter
with the circuit for measurement. a. Connect the black test lead to the “COM”
jack and the red test lead to the “mA” jack for a maximum of 660mA current.
For a maximum of 10A, move the red lead to the 10A jack.
b. Select A, enter the DC current measurement, the screen display “DC
current”, can select manual range.
WWW.RSRTENG.COM
Page.79.
c. Manual range:
X7 SERIES CAMERA TESTER User Manual
0.000mA 6.6mA range 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A
range(use 10A socket)
d. Select the range to enter current measurement
NOTE: When only the figure “OL” is displayed, it indicates over range
situation and the higher range has to
be selected. When the value scale to be measured is unknown beforehand, set
the range selector at the highest
position. The maximum current of mA socket is 660mA, over-current will destroy
the fuse, and will damage
the meter. The maximum current of 10A socket is 10A, over-current will destroy
the meter, and will damage
the operator.
D. AC Current Measuring (Only Manual range)
WARNING! Shut down the power of the tested circuit, and then connect the meter
with the circuit for measurement.
a. Connect the black test lead to the “COM” jack and the red test lead to the
“mA” jack for a maximum of 660mA current. For a maximum of 10A, move the red
lead to the 10A jack.
~ b. Select A, enter the AC current measurement, manually select
the range.
WWW.RSRTENG.COM
Page.80.
X7 SERIES CAMERA TESTER User Manual
c. Manual range: 0.000mA 6.600mA range 00.00mA 66.00mA range 000.0mA 660.0mA range 00.00A 10.00A range (use 10A socket)
Note: When only the figure “OL” is displayed, it indicates over range
situation and the higher range has to
be selected. When the value scale to be measured is unknown beforehand, set
the range selector at the highest
position. The maximum current of mA socket is 660mA; over-current will destroy
the fuse, and will damage
the meter. The maximum current of 10A socket is 10A, over-current will destroy
the meter, and will damage
the operator. In “AC” mode, only can input “AC “, if not, will damage the
meter. E. Resistance Measuring
WARNING! When measuring in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have discharged fully.
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/” jack. b. Select , enter the measurement
The tester default Auto range status, Press the key manually select
range, press “NEAR” to restore “Auto range”
Manual range: (Connect the red lead to black leads, will display the
measure range)
000.0 660 range
WWW.RSRTENG.COM
Page.81.
X7 SERIES CAMERA TESTER User Manual
F. Continuity Testing
0.000 K 6.600K range 00.00 K 66.00K range 000.0 K 660.0K range 0.000 M 6.600M range 00.00 M 66.00M range
WARNING! When testing the circuit continuity, be sure that the power of the circuit has been shut down and all capacitors have been discharged fully.
a. Connect the black test lead to the “COM” jack and the red test lead to the
“V/” jack.
b. Select , enter the continuity test, Connect test leads across two point of
the circuit under testing. c. If continuity exists (i.e., resistance less than
about 50), built-in
buzzer will sound. G. Diode Testing
WARNING! The capacitance of a capacitor should be tested separately, should
not test in the installation
of circuit.
a. Connect the black test lead to the “COM” jack and the red test lead
to the “V/” jack. (the red lead anode “+” )
b. Select , enter the diode testing. c. Connect test red lead across to the
anode, the black lead to the
cathode of the diode under testing. d. Connect test red lead across to the
cathode, the black lead to the anode of the diode under testing. e. Tested
diode, forward voltage low 30m, there is sound indication, then can finish the
testing quickly without view the screen.
WWW.RSRTENG.COM
Page.82.
H. Capacitance Measuring
X7 SERIES CAMERA TESTER User Manual
WARNING! To avoid electric shock, be sure the capacitors have been discharged fully before measuring the capacitance of a capacitor.
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/” jack.
b. Select ” “, enter the capacitance measurement.
c. The tester default auto range status, and manual range by press upward and downward key, Auto rang
by press the key “NEAR” Manual range: 0.000nF 00.00nF 000.0nF
6.600nF range 66.00nF range 660.0nF range
0.000uF 00.00uF 000.0uF 0.000mF 00.00mF
6.600F range 66.00F range 660.0F range 6.600mF range 66.00mF range
d. Before connect test leads across two sides of the capacitor under measurement, be sure that the
capacitor has been discharged fully.
Note:
a. The capacitance of a capacitor should be tested separately, should not test
in the installation of circuit. b. To avoid electric shock, be sure the
capacitors have been discharged fully before measuring the capac
itance of a capacitor.
c. While testing the capacitance of a capacitor to 660uF, the Max time will be
6.6 seconds, if the capacit
or is leaked or damaged, the data can’t be read. The tester will be normal
after disconnecting the capacitor.
WWW.RSRTENG.COM
Page.83.
X7 SERIES CAMERA TESTER User Manual
Manual range and Auto range When testing, click “Range select” to change the
value, click “Auto range” to enter Auto measurement.
Data hold Click “Hold data” to enter, the data be hold, the value is green.
Press it again to quit.
Relative value measurement Click “Relative “to enter, the tester Auto-save the
data, the displayed new measurement and relative value is red color. Press it
again to quit.
The hold function and the relative value be combined use, the display value is
yellow The meter protection Voltage protection
You can’t input the voltage which more than 660V AC, it’s possible to show
higher voltage, but it’s may destroy the inner circuit. Resistance,
Continuity, Diode, PTC component Protection Wrong input voltage, will Auto
enter protection state, It only suitable for short and limit time work. If
input voltage over 600V, will damage the meter. mA current fuse range: 250V 1A
If the current over the rated range, fuse will melt to protect the meter
.Please use the same model
WWW.RSRTENG.COM
Page.84.
X7 SERIES CAMERA TESTER User Manual
when change the fuse, Please opens the battery cover to change.
Note: 10A socket without fuse protection, if over the current range Wrong
using the 10A socket to measure the voltage, will damage the meter.
3.3.30 Optical power meter* (Only for X7-MOVTADHS)
Click icon
to enter, with five wavelength 1625nm, 1550nm, 1490nm, 1310nm, 1300nm,
850nm, linear or nonlinear optical power display, both for optical power testing and Fiber link loss
relative measurement. It is necessary tool for installation and maintenance optical fiber communication,
cable television and CCTV security system.
Note: Please keep the fiber connector and the dust cap be clean, and clean the detector with the special alcohol. Data hold While testing, click “Hold” to data hold, the data will not change. It’s convenient to read. Press again to quit.
Relative power value (optical link loss) measurement While testing, set the wavelength for measurement. Click “relative”(difference) to test, the tester Auto save current fiber power value as the base reference value. Input another optical fiber to be measured, the displayed new measurement and relative value is red color. Press it again to quit.
WWW.RSRTENG.COM
Page.85.
X7 SERIES CAMERA TESTER User Manual
Data hold and Relative measuring use together, the data is yellow while the
function is effect.
WWW.RSRTENG.COM
Page.86.
X7 SERIES CAMERA TESTER User Manual
3.3.31 Visual Fault Locator* (Only for X7-MOVTADHS)
Click icon
to enter
VFL four status can select—-“Steady mode”, “Evasive 1Hz”,”Evasive 2Hz”and “Time off”. Click button “Steady mode” to enter steady status, click button “Evasive 1Hz” and “Evasive 2Hz”, to enter pulse mode, click button “Time off “, VFL is turned off. Timed turn off can select (5 mins, 10 mins, 30 mins, 60 mins and 120 mins). Click “Steady mode”, red laser source emits steady, click again to quit.
Click icons “Evasive 1Hz”or “Evasive 2Hz” to enter pulse mode, the red laser source is emitted by a certain frequency, press it again to quit
WWW.RSRTENG.COM
Page.87.
X7 SERIES CAMERA TESTER User Manual
3.3.32 Audio Record
Connect an audio device to the IP tester’s audio input port. Click the
icon to enter the Audio
Recorder app. Click the red button to stop, and the unit will prompt you to save the recording.
3.3.33 Data monitor
Please click icon
to enter
Click “Setting” to choose the baud rate of RS485, it must be the same as the DVR or the Control
keyboard. The DVR or Control keyboard send the code to the tester, if it can be read, the protocol will
show on the upper right, like Pelco-D, if not, like P:—
While the tester receives the code, press the
key to empty.
Though the RS485 port, display the PTZ control code of the multifunctional keyboard or the DVR.
Controller can check the status of the RS485 transmission through the code on the display. (The RS485
communication rate must be the same.)
Application: Check the RS485 communication states of the video optical transmitter whether normal.
Engineer can analyze the protocol and check the data through the displayed code.
WWW.RSRTENG.COM
Page.88.
X7 SERIES CAMERA TESTER User Manual
3.3.34 Audio player
Click the icon
to enter. The audio player only supports MP3 format Audio files.
3.3.35 Media Player
Click the icon
to enter
The Media player can browse video and image files. It supports the video formats of MP4, H.264, MPEG4, and MKV. The IP tester recorded files can play directly via the Media player. The Media player will automatically display the video files from the SD card. Click on the desired file to play. Click RETURN to exit. To rename or delete an existing file, press the file name for a few seconds until the screen below appears. You can then rename or delete the file by pressing the desired option.
WWW.RSRTENG.COM
Page.89.
X7 SERIES CAMERA TESTER User Manual
3.3.36 RTSP Player
The RTSP Player app will allow you to view the RTSP video stream from an IP
camera. If you were unable to view your camera via the ONVIF or IPC Test apps,
it is possible your camera will have an RTSP stream and you can view live
video. From the main menu, select the “APP Tool” folder and then select the
“RTSP Player” to open the app. If the IP camera uses MJPEG, select the RTSP
icon. If the IP camera uses H.264, select the “RTSP HD” icon.
WWW.RSRTENG.COM
Page.90.
X7 SERIES CAMERA TESTER User Manual
Local IP: This is the IP testers IP address. RTSP Add: This is where you can
manually enter the IP camera’s RTSP URL or click on Search to search the
network for cameras that use an RTSP stream. IPC Username: Enter the IP
camera’s user name. IPC Password: Enter the IP camera’s password. Once you
have entered all the necessary information, select Enter at the bottom left to
view the RTSP stream.
Note: In the event the IPC tester does not auto detect the RTSP stream, refer
to the specific camera manufacturer for the specific RTSP stream URL. you may
find this on line with a search of the camera model number and the word RTSP.
WWW.RSRTENG.COM
Page.91.
X7 SERIES CAMERA TESTER User Manual
3.3.37 Hik test tool
Hik test tool app is design for activating and debugging Hikvision camera, can auto-identify
Inactivated hikvision camera, also can display image from the Hikvision camera.
Tap icon
to enter
Activation: Select left [online detection] to display the “inactivated” camera and click activate.
“Activation” and “Batch activation” are optional.
Auto open ONVIF protocol: After activation, the new HIK cameras click “play, modify the channel name, modify network information, modify user information” any one of to auto open the selected camera ONVIF protocol.
WWW.RSRTENG.COM
Page.92.
X7 SERIES CAMERA TESTER User Manual
Play: Security status shows the “activated” camera. Enter the correct camera
password in the right [password] and click [play] to pop up the “private
protocol” or “speed ONVIF” two options. Select the protocol you need to see
the camera images.
Modify channel name: Clicking “Modify the channel name” will pop up OSD
settings, including time, channel name and other optional items. After channel
selecting, you can edit the channel name, modify the display position, and
switch the font size. Select “default location” in “content location” is
without modification. Select “Customization” to arbitrarily adjust the channel
name and display location. Click “OK” and the effects will appear. Press
return key or click any area of the screen to return to the upper layer of the
interface.
WWW.RSRTENG.COM
Page.93.
X7 SERIES CAMERA TESTER User Manual
Modify network information: Support “modify” and “batch modify” camera IP
address, subnet mask and other parameters modification.
Enter a new IP address and subnet mask, the default gateway will be auto
modified according to the IP address. Click “OK” to save the changes.
WWW.RSRTENG.COM
Page.94.
X7 SERIES CAMERA TESTER User Manual
Modify user information: Modify the camera’s user name and password.
Factory Reset: Camera factory reset.
3.3.38 DH test tool
DH test tool is developed for installation and debugging of the Dahua IP
camera, it can display image, and modify IP, user name and password etc.
Making Dahua camera test more convenient and quickly.
WWW.RSRTENG.COM
Page.95.
X7 SERIES CAMERA TESTER User Manual
Activation: select left [online detection] to display the “inactivated” camera
and click activate.
Activate and Batch activate are optional, support reserved phone number for
resetting password.
WWW.RSRTENG.COM
Page.96.
X7 SERIES CAMERA TESTER User Manual
Play: When mode display “activated” camera, input correct password, click
“Play” poping up “private protocol” and “ONVIF”, Select correspond protocol to
view the camera image.
Modify Channel: Click “Modify Channel”, will pop up OSD setting, includes time, channel name etc.
WWW.RSRTENG.COM
Page.97.
X7 SERIES CAMERA TESTER User Manual
After selected Channel name, can edit channel name, modify the display
position and font size. If select “Default position” of Content location, then
no need to modify. If select “customize”, then can modify Channel name and
display position, click “OK” to view the image. Click “Back” or “Return”
button to return previous interface.
WWW.RSRTENG.COM
Page.98.
X7 SERIES CAMERA TESTER User Manual
Modify Network: Support Modify and batch modify two way, can modify camera IP
address, Subnet mask and gateway.
Input new IP address, need to input password, click “OK” to save the
modification
WWW.RSRTENG.COM
Page.99.
X7 SERIES CAMERA TESTER User Manual
Modify user information: Modify camera user name and password, which is Onvif,
Dahua test tool, IPC TESTE user name and password, not web user name and
password.
Factory reset setting: Camera will be soft reset, and the device’s user name,
password and network set be saved. Other settings information is factory
reset.
WWW.RSRTENG.COM
Page.100.
X7 SERIES CAMERA TESTER User Manual
3.3.39 Update
Copy the downloaded update file to SD card “update” directory, if no directory, please create one.
Click the
icon to open the Update menu. Select “Local Update” to update via the SD card or
select “Online Update” to check for updates on the internet. If there are applications that need updating,
the applications will be displayed on the
If there are update programs, applications will be listed in the interface,
click related applications, update to the latest version. Update online:
Before using online update, need enter settings-user management to register
first. System update: Connect the Internet to update systems.
3.3.40 Office
Quick office app (support excel, word, ppt format) doc. editable
WWW.RSRTENG.COM
Page.101.
X7 SERIES CAMERA TESTER User Manual
3.3.41 LED Flashlight
It is convenient for the installation or maintenance in the evening or in the dark. Click icon
to
enter
While in the flashlight app, click the red button to turn on the LED lamp. Press it again to turn it off. If
you don’t press the red button
to shut off the lamp and press the button to exit the app, the lamp
will stay on. Click the Time Setting button to set a timer that will shut off the lamp.
3.3.42 Browser
Click icon
to enter
Type in the camera’s IP address and press “Go” to access the IP camera’s interface.
NOTE: The web view plug-in of the existing IP cameras only supports Windows operating system, and our tester is based on Android system, so you will can’t view the live image in the tester’s browser. For viewing video, please use the IP tester’s live camera view Apps. However, some brands of cameras can still view and set parameters through the browser, just cannot be previewed in real time.
WWW.RSRTENG.COM
Page.102.
X7 SERIES CAMERA TESTER User Manual
The IP camera and IP tester be on the same network segment for the browser to interface with the
camera. If they are not in the same segment, click the button
or press “RETRUN” to exit. Open
the “Settings” app from the main menu to change the IP tester’s network settings to match those of the
IP camera.
3.3.43 Notepad
Notepad can be used to record the important testing results, click the key
“Save” to save the contents. Notepad can auto record the storage date and
time.
.
Please click
to view the notepad, all saving contents display. Click each record bar to show the
details. Press the record bar for several seconds, prompt whether delete it.
WWW.RSRTENG.COM
Page.103.
X7 SERIES CAMERA TESTER User Manual 3.3.44 Professional WiFi Analyzer
Detect the surrounding wifi signal and signal strength, support 2.4G and 5G
frequency band.
Access point list and List format, display WIFI’s channel, frequency, signal
strength, device information and distance, etc.
WWW.RSRTENG.COM
Page.104.
3.3.45 System Setting
Click icon
to enter
X7 SERIES CAMERA TESTER User Manual
Language: Select your desired language: English, Chinese, Korean, Russian, Italian, Polish, Spanish, French or Japanese, German, Turkish etc. Typewriting: You can select typewriting or install other typewriting: Date/Time: Set the Date/time of the IP tester IP setting: Manually set the IP address, Subnet Mask, Default Gateway and DNS address or select “Dynamic allocation” to use DHCP. To test multiple network segments, click “Advanced” and then click “Add” to enter another IP address for the IP tester.
After setting an advanced IP address (refer to the photos above), the unit can test two network segments (192.168.5.0) and (192.168.1.0)
WWW.RSRTENG.COM
Page.105.
X7 SERIES CAMERA TESTER User Manual
WLAN Net: Turn WiFi off or on by pressing the “Open the wifi” button. Once
WiFi is turned on, and click connected WiFi, it will scan for wireless
networks in your area.
Select and press “WIFI” several seconds, to set static IP address.
Wi-Fi hotspot: Input “SSID” name and “password”, and then click “ok” to create
Wi-Fi hotspot.
WWW.RSRTENG.COM
Page.106.
X7 SERIES CAMERA TESTER User Manual
Brightness: Set the desired brightness of the IP tester and adjust the sleep
time settings. Volume: Set volume level SD Card: Displays SD Card Capacity.
You can also format the SD card or un-mount it before removing it. FTP server:
Once the IP tester connects to a network, a computer can be used to read the
SD card files via FTP
Start the FTP server and then input the tester’s FTP address in the PC’s
address bar. This will enable the PC to read, copy and edit the files from the
SD card without the use of SD card reader.
WWW.RSRTENG.COM
Page.107.
X7 SERIES CAMERA TESTER User Manual
Version Information: Shows applications version information, if press any apps
icon several seconds to uninstall. Screen display rotation: Click on “Screen
Rotation” to flip the IP tester’s display 180 degrees. This function is very
convenient for the user to connect the LAN cable on the bottom of the unit
without having to flip the unit itself. PTZ address scan: You can toggle the
PTZ Address scan off or on before entering the “PTZ controller” app. This
needs to be turned on in order to use the PTZ Scan feature of the PTZ app.
Online Registration: Online update need register first, after the tester
connect to network, then fill registration information to register. User
Feedback: If you have any comments or suggestions for the tester, please
connect it to network and write your feedback. Lock Screen: The meter default
is not locked. You can choose password Lock screen, pattern Lock screen or
“NO”. Password Lock Screen: Set password, you can input digitals, letters or
characters as password, input it again to confirm .when the meter is in
standby mode or turn it on, you can input your password to enter. Pattern Lock
Screen: Drawing a pattern to lock. While the meter is in standby mode or turn
it on, you can input your pattern to enter. Modify Lock screen password, you
need input lock password again. Select password Lock screen or pattern Lock
screen to reset lock screen password. After reset pattern lock screen, you
need to draw a new lock pattern. Restore the factory settings: If the tester
to restore factory settings, all your personal files and apps will be removed.
WWW.RSRTENG.COM
Page.108.
X7 SERIES CAMERA TESTER User Manual 3.3.46 File explorer
Click “File” on the top bar tool, can select internal or external storage.
Click on the upper right corner Icon”… “. Will pop-up menu, you can select
other operation or exit.
Browse It includes Music, Videos, Pictures, Documents, zip file etc. It is
convenient to view and manager.
WWW.RSRTENG.COM
Page.109.
X7 SERIES CAMERA TESTER User Manual
FTP server You can choose internal or external SD card. Other operation
details, please refer to FTP settings.
3.3.47Audio test
You can test the audio input from audio pickup devices by connecting the audio
pickup device to the IP tester with the supplied audio cable.
WWW.RSRTENG.COM
Page.110.
X7 SERIES CAMERA TESTER User Manual
4. Specifications
4.1 General Specifications
Product
Rsrteng X7 Series IP Camera Tester*models Optional
Display
New 7 inch retina touch screen, 1920*1200 resolution
Network port
Dual RJ45 LAN port, 10/100/1000Mbps auto adjust
WIFI
Built in WIFI, speeds 150M, allows you to connect to a wireless network and view IP cameras. Operating Frequencies: 2.4G and 5G
New hardware decoding, 4K H.265/H.264 camera image display by H.265 Mainstream
test
mainstream testing
IP discovery
Auto-scan the whole network segment camera IP
Rapid ONVIF
Search camera quickly, auto log in and display image from the camera, activate Hikvision camera
Batch activate Hikvision camera, display image from the camera,
Hik test tool
modify Channel, batch modify IP, user name and password parameters
etc.
DH test tool
Batch activate Dahua camera, batch modify IP, modify Channel, user name and password parameters etc.
IP camera type
ONVIF, Non-ONVIF, Dahua, Hikvision, Samsung, Axis, Tiandy, Kodak, Honeywell, RTSP Viewer
AutoHD*
Auto-recognize the resolution and Auto-display the image of the
(only X7-ADH, X7-ADHS, connected camera. Support coaxial PTZ control and call OSD menu,
X7-MOVTADHS)
support up to 8MP TVI/CVI/AHD and CVBS cameras.
4K HD Coaxial level Through hardware high-speed sampling and processing technology, acc
test* (only
urately measure video peak level, sync level and burst level. By one
X7-MOVTADHS)
key to create testing report.
SDI video signal test* 1 channel HD-SDI/EX-SDI input (BNC interface), resolution support:
(only X7-ADHS,
720P 60fps, 1080P 60fps, 1080i 60fps, EX-SDI: 2560 x1440P
X7-MOVTADHS)
/25/30fps, 3840 x 2160P 25/30 fps, UTC control and call OSD menu
WWW.RSRTENG.COM
Page.111.
X7 SERIES CAMERA TESTER User Manual
CVI video signal test*
(only X7-ADH, X7-ADHS, X7-MOVTADHS)
1 channel CVI input (BNC interface), resolution support 720P 25/30/50/60fps, 1080P 25/30fps, 2560x1440P 25/30fps, 2592×1944 20fps, 2960×1920 20fps, 3840 x 2160 12.5/15 fps. UTC control and call OSD menu
TVI video signal test*
(only X7-ADH, X7-ADHS, X7-MOVTADHS)
1 channel TVI input (BNC interface), resolution support 720P 25/30/50/60fps, 1080P 25/30fps, 2048x1536P 18/25/30fps, 2688x1520P 15fps, 2560x1440P 15/25/30fps, 2560x1944P 12.5/20fps, 3840 x 2160 12.5/15 fps, UTC control and call OSD menu
AHD video signal test*
(only X7-ADH, X7-ADHS, X7-MOVTADHS)
1 channel AHD input (BNC interface), resolution support 720P 25/30fps, 1080P 25/30fps, 2048x1536P 18/25/30fps, 2560x1440P 15/25/30fps, 2560x1944P 12.5/ 20fps, 3840 x 2160P 15 fps, UTC control and call OSD menu
CVBS video test
1 ch BNC Input & 1 ch BNC Output , NTSC/PAL (Auto adapt)
Video level meter
PEAK video signal level, SYNC signal level, COLOR BURST chroma level measurement for CVBS camera.
Zoom Image
Supports Analog and IP camera image zooming & movement
Snapshot, Video
Capture current images and record live video as JPG file. Media player
record and playback will view photos and playback video
1ch, support max 4K 3840x2160P 30fps,
HDMI input
720×480P/720×576P/1280×720P/1920×1080P/1024×768P/1280×1024
P/1280×900P/1440×900P
HDMI output
1 channel HDMI output, supports up to 4K 30FPS
RJ45 cable TDR test
RJ45 cable TDR test and cable quality test, to test cable pair status, length, attenuation reflectivity, impedance, skew and other parameter.
DC24V/2A Output power to camera
Power output
DC12V/3A Output power to camera DC5V/2A power output
Standard PoE IEEE802.3af/at power output, DC48V, Max 25.5W
WWW.RSRTENG.COM
Page.112.
X7 SERIES CAMERA TESTER User Manual
Screen management
Under normal mode, you can change icons sequence and self-define the number of icons in each page
Theme drop-down menu
Audio test PTZ control
Color bar generator UTP Cable tester Data monitor
Net tool pro
Cable tracer PoE /PSE voltage test Digital Multi-meter
(only X7-MOVTADHS)
Optical power meter
(only X7-MOVTADHS)
Self-define icons, desktop and application interface background, modify interface sliding effect. PoE power switch, IP setting, WLAN switch, HDMI IN functions etc screen lock, password lock screen or pattern lock 1 ch audio signal input and 1 ch audio signal output test. Support RS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc Output one channel CVBS PAL/NTSC color bar video signal for testing monitor or video cable.(red, green, blue, white and black color ) Test UTP cable connection status and display on the screen. Read the number on the screen Captures and analyzes the command data from controlling device, also can send hexadecimal NET TOOL PRO-Cable Test, Wireless Tool, Link Tool, Full Duplex Detection, PING, IP Scan, DHCP Server, PPPOE, OUI Search, Socket Tool, DNS, LLLDP. Using the advanced multiplexing technique, the cable tracer and cable test in the same interface. Find a connected cable from a bundle of cables using audio tones Measures PoE switch voltage and displays pin configuration AC/DC Voltage, AC/DC current, Resistance, Capacitance, Data hold, Relative measurement, Continuity testing. Testing speed: 3 times/ seconds, Data range -6600+6600. Calibrated Wavelength(nm): 850/1300/1310/1490/1550/1625nm Power range(dBm): -70+10dBm
WWW.RSRTENG.COM
Page.113.
X7 SERIES CAMERA TESTER User Manual
Visual fault locator *
(only X7-MOVTADHS)
Test fiber’s bending and breakage ( SM and MM fiber)
TDR cable test*
(only X7-MOVTADHS)
BNC cable, network cable, telephone cable, RVV cable and elevator cable, cat 5/6 cable’s length and short circuit. measurement range 1.2KM
BNC attenuation test*
(only X7-MOVTADHS)
Through hardware high-speed sampling and processing technology, test the BNC coaxial cable transmission attenuation value, detect the transmission quality of BNC cable.
External power supply DC 12V/2A
Battery
Built-in 7.6V Lithium polymer battery, 7800mAh, 59.28Wh
Rechargeable
Fasting charge, after charging 3.5 hours, normal working time 16 hours
Capacitive touch screen, OSD menu, select your desired language:
Operation setting
English, Chinese, Polish, Italian, Korean, Russian, Spanish, Japanese,
French, German, Turkish, Portuguese, Vietnamese, etc.
Auto off Working Temperature
1-30 (mins) -10—+50 (14—122)
Working Humidity 30%-90%
Dimension / Net Weight
265x160x45mm / 1100g (10.43×6.3×1.77inch / 2.4lbs)
4.2 Multi-meter specifications
Counts: -6600+6600 Conversion rate: 3times/s Current modes for clamp meter
with ZERO function Isolation: the Multi-meter connector must be isolated with
the other connector.
WWW.RSRTENG.COM
Page.114.
DC voltage Range
660mV (Manual range) 6.600V 66.00V 660.0V
AC voltage Range
660.0mV (Manual range) 6.600V 66.00V 660.0V
DC current Range
6.600mA 66.00mA 660.0mA 10.00A
AC current Range
6.600mA 66.00mA 660.0mA 10.00A
X7 SERIES CAMERA TESTER User Manual
Accuracy ±0.3%+4
Resolution 0.1mV 1mV 10mV 100mV
Accuracy ±1.5%+6
±0.8%+6
Resolution 0.1mV 1mV 10mV 100mV
Accuracy ±0.5%+3 ±1%+5
Resolution 1uA 10uA 100uA 10mA
Accuracy ±0.5%+3 ±1%+5
Resolution 1uA 10uA 100uA 10mA
WWW.RSRTENG.COM
Page.115.
X7 SERIES CAMERA TESTER User Manual
Resistance Range
660.0 6.600K 66.00K 660.0K 6.600M 66M Continuity
Range
Resolution
660.0
0.1
Diode Range
Resolution
2.0V
1mV
Capacitance Range
6.600nF 66.00nF 660.0nF 6.600F 66.00F 660.0F 6.600mF 66.00mF
Accuracy ±0.8%+5
±0.8%+2
±1.2%+5
Resolution 0.1 1 10 100 1K 10K
Function The measurement value less 30±3,the tester will sound
Function Schottky diode:0.15~0.25V rectifier diode:0.6~1.0V triode PN junction:0.5~0.8V
Accuracy ±0.5%+20 ±3.5%+8
±5%+8
Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1F 10F
WWW.RSRTENG.COM
Page.116.
X7 SERIES CAMERA TESTER User Manual
4.3 Optical power meter specifications
Measure Range(dBm)
-70+10dBm
Wavelength(nm) Detector Uncertainly Display Resolution
850nm,1300nm,1310nm,1490nm,1550nm,1625nm InGaAs
±3%dB(-10dBm,22) ±5%dB(full range,22)
Linear:0.1% ; Nonlinear:0.01dBm
Operating Temperature() Storage Temperature ()
-10+50 -20+70
Connector type
FC/PC
4.4 Visual fault locator specifications
Laser type
LD
Wavelength Calibration
650nm
Output power
10mW
Modulation mode
Measurement Range Connector Working Temperature Operating Temperature
CW/1Hz/2Hz
10KM FC/PC exchangeable -10+50 -20+70
NOTE:The data above is only for reference and any change of them will not be informed in advance. For more detailed technical inquiries, please feel free to call the Technical Department of our company.
WWW.RSRTENG.COM
Page.117.
Contact us
X7 SERIES CAMERA TESTER User Manual
You can get more information and support by: Website: www.rsrteng.com Sales department: sales@rsrteng.com After-sales support: service@rsrteng.com Tel: +86-755-32974680
Thank you!
WWW.RSRTENG.COM
Page.118.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>