bticino BT12WVKIT Multi Way Door Entry Kits Installation Guide

June 15, 2024
bticino

BT12WVKIT Multi Way Door Entry Kits

bticino BT12WVKIT Multi Way Door Entry Kits MULTI WAY AUDIO AND VIDEO
DOOR ENTRY KITS
18 WAY VIDEO DOOR ENTRY KIT![bticino BT12WVKIT Multi Way Door Entry Kits

If you require assistance, please contact our  technical support helpline on 0370 608 9020or email doorentry.uk.technical@legrand.com
bticino BT12WVKIT Multi Way Door Entry Kits - fig 1We recommend Bticino cable Cat. No. 3369 04, see guidance notes for usage of different cable types
BUS cable connections are non polarised meaning the cable cores can be terminated in either connection terminal

ALL CONFIGURATION SHOULD BE DONE WHILE THE SYSTEM IS POWERED OFF!

ENTRANCE PANEL CONFIGURATION

bticino BT12WVKIT Multi Way Door Entry Kits - fig 3 EXAMPLE HANDSET CONFIGURATION     bticino BT12WVKIT Multi Way
Door Entry Kits - fig 2■ If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com

DOOR LOCK WIRING EXAMPLES

EXAMPLE 1 – Fail secure door dock (energise to open)bticino BT12WVKIT Multi
Way Door Entry Kits - fig 4EXAMPLE 2 – Fail safe door dock (de-energise to open)  ![bticino BT12WVKIT Multi Way Door Entry Kits

ENTRANCE PANEL MOUNTING AND CABLING GUIDELINES

BACKBOX SIZES Dimensions (mm)

Cat. Nos. A B C
BT4WAKIT 151 151 82

BT4WVKIT
BT6WVKIT
BT6WAKIT
BT8WVKIT
BT8WAKIT
BT10WVKIT
BT10WAKIT
BT12WAKIT| 151| 242| 82
BT12WVKIT
BT14WVKIT
BT14WAKIT
BT16WVKIT
BT16WAKIT
BT18WVKIT
BT18WAKIT| 151| 334| 82

RECOMMENDED MOUNTING HEIGHTS AND FIELD OF VIEW (to centre of camera) bticino
BT12WVKIT Multi Way Door Entry Kits - BACKBOX SIZES 1

CABLING GUIDELINES

LINE
max. distance| 2 core untwisted
0.2 mm| Cat 5 single twisted
pair| Telephone single
twisted pair 0.28 mm| Bticino
3369 04/3369 05
---|---|---|---|---
A| 50 m| 125 m| 125 m| 200 m
B| 50 m| 70 m| 70 m| 150 m
C| 50 m| 75 m| 75 m| 170 m
D| 10 m| 30 m| 30 m| 50 m

Recommended cable 3369 04/3369 05 for best performance
We cannot guarantee the performance of 3rd party cable suppliers

OPTIONAL ADVANCED SETTINGS AND FEATURES

FLOOR CALL (doorbell) A non-illuminated bell push can be wired to the pushbutton terminals of the internal handset, this will ring the internal unit with a different audio tone to let you know that somebody is at the apartment door
This removes the need to install a separate bell transformer and chime The maximum distance between the call to the floor push button and the internal unit is 15 m
DOOR LOCK TIMING (T configuration)bticino BT12WVKIT Multi Way Door
Entry Kits - BACKBOX SIZES 4 Jumpers in slots J1 and J2 may vary depending on kit used, please see p. 3 for required configuration details
As default, the speaker module without a configurator in the “T” slot will allow the door lock to operate for 4 seconds, if a different door lock operation time is desired, you can change the door lock timing to match the table below (additional purchase of configurators may be required)
Configurator Number

0
(no configurator)| 1| 2| 3| 5| 6| 7
---|---|---|---|---|---|---
4 sec| 1 sec| 2 sec| 3 sec| 6 sec| 8 sec| 10 sec

For door lock times greater than 10 seconds and/or different lock requirements please contact our technical support team who would be more than happy to assist

TROUBLESHOOTING

System does not power up

  • Check the incoming supply of the power supply is 230 V
  • Check the BUS voltage on BUS terminals of all devices is 27 V DC
  • Check for loose connections on the system

System powers up but does not call correctly

  • Check the BUS is 27 V DC is at every point, including entrance panel and internal handsets and make sure that the BUS is wired to the correct terminals on each device
  • Check entrance panel and handset configurators are correct, please see the configuration guide on p. 3
  • Reset the power to the system. The configuration must be done with the system powered off as the configuration only gets read into the system when it is powered up
  • Check you are pressing the correct call button, please see the call button positions on p. 3 which shows the configuration positions of the call buttons
  • Check the JMP configurator is correct in the J1 slot of the entrance panel as shown on p. 2 and 3, once this has been changed a power reset must be performed to read in the new configuration
  • If the handset is not calling, check the ringer volume settings on the right-hand side of the internal unit to make sure the ringer volume is at a suitable level, see p. 3

Door lock is not working correctly

  • Check 12-18 V DC is on terminals S+ and S- of the entrance panel whilst the door lock button on the handsets is being pressed
  • Check the door lock wiring is correct for the type of door lock you have, see p. 4
  • Check the push to exit button (if installed) is a sprung return N/O push switch

Video has interference

  • Low voltage cabling should not be run with mains equipment, check the wiring runs are not being run along with power cables anywhere on the system
  • Check end of line switches are set to the ‘ON’ position for every internal handset as shown on p. 3
  • Make sure you are using the correct type of twisted pair cabling as recommended within the cabling guidelines shown on p. 5 (do not double up on a cat 5, use a single twisted pair i.e. brown pair)
  • Check BUS TK and BUS PI connections on the power supply are wired correctly. BUS TK should feed the entrance panel and BUS PI should feed the internal units/distribution blocks

Audio low / squealing

  • If you hear squealing at the entrance panel during conversation (Larson effect) this could be due to the mic and loudspeaker adjustments both being set too high causing the A/V module to self amplify. Fine tune the mic and speaker until squealing stops and  the desired audio level is achieved. These can be found on the front of the A/V module and adjusted using the orange adjustment tool supplied with the A/V module, see p. 3
  • Low speech audio can be rectified with fine tune adjustment to the mic and loudspeaker. The settings for these are located on the front of the A/V module of the entrance panel and can be changed using the orange adjustment tool supplied with the A/V module, see p. 3

If you require assistance, please contact our technical support helpline on 0370 608 9020 or email doorentry.uk.technical@legrand.com

Contact details
United Kingdom
Great King Street North,
Birmingham, B19 2LF
Customer Services:
Tel: +44 (0) 345 605 4333
E-mail: legrand.sales@legrand.co.uk
Quotations and Technical Support:
Tel: +44 (0) 370 608 9020
E-mail: doorentry.uk.technical@legrand.com
Republic of Ireland:
Tel: 01 295 9673
E-mail: legrand.sales@legrand.co.uk

FOLLOW US AT
www.legrand.co.uk
www.legrandie
www.youtubescom/legrandtvuk
www.twitter.comnegranduk
www.linkedin.com/cornpanyilegranduk
In accordance with its policy of continuous improvement, the Company reserves the right to change specifications and designs without notice. All illustrations, descriptions, dimensions and weights in this catalogue are for guidance and cannot be held binding on
the Company. All contents and design presentation included in this publication are © Legrand Electric Limited. All rights reserved. 2023.

Head office (UK and Ireland):
Legrand Electric Limited Great King Street North, Birmingham, B19 2LF
Tel: +44 (0) 370 608 9000
Website:www.legrand.co.uk
The Legrand logo is a registered trademark of the Legrand group of companies.
Bticino multi way door entry kits installation guide 10/2023

Documents / Resources

| bticino BT12WVKIT Multi Way Door Entry Kits [pdf] Installation Guide
BT12WVKIT Multi Way Door Entry Kits, BT12WVKIT, Multi Way Door Entry Kits, Door Entry Kits, Entry Kits, Kits
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

bticino User Manuals

Related Manuals