bticino MyHOMEServer1 MyHOME Server Owner’s Manual

June 10, 2024
bticino

bticino MyHOMEServer1 MyHOME Server

bticino MyHOMEServer1 MyHOME Server

Description

The MyHOME Server is a device designed to interact with the MyHOME (1) (2) by means of the Home + Control app for smartphone and tablet (available in the stores for Android and iOS systems).

In particular thanks to this device one can:
Start the MyHOME system

  • Concerning the Lights(3), Automation(3) and Temperature Control(3) systems the system is started via the MyHOME Server directly using the Home + Project application.
  • Energy management system can be configured via MyHOME Server using MyHOME_Suite PC software.

Interact with the MyHOME system

  • The MyHOME (4) system can be controlled via the MyHOME Server and third party devices (5) via the Home + Control. Both the installer (using the Home + Project App) and the user (using the Home + Control App) can perform customisations and create scenarios for managing the MyHOME system.

Note :

  1. MyHOME Server is only compatible with the Home + Project application and with the MyHOME_Suite software.
  2. The new Living Now civil series is compatible with firmware versions after 2.1, or app versions after 2.2
  3. For correct operation it is fundamental that the connection is made on the private riser BUS (level 3) of the automation system (see MyHOME Automation Guide).
    NOTE : It is not possible to have more than 175 channels per system. Home
  • Project will issue a warning when this limit is exceeded. It is not possible to install the MyHOME Server on systems with logical expansion.

    1. The MyHOME Server manages the Light, Automation, Temperature control, Energy Management, Burglar-alarm systems.
    2. For example one can interact with Philips Hue® and Lifx® lamps, …

Front viewbticino MyHOMEServer1 MyHOME Server 1

Technical data

  • Power supply from SCS BUS: 18 – 27 Vdc
  • Supplementary power supply (optional): 18 – 27 Vdc
  • Absorption from SCS BUS without additional power supply: 130 mA max
  • Absorption from SCS BUS with additional power supply: 3 mA max
  • Absorption from additional power supply: 160 mA max
  • Operating temperature: 5 – 35 °C
  • Default fixed IP address: 192.168.0.55

Dimensional data

  • Size: 6 DIN modules

Legend

  1. RJ45 for Ethernet LAN 10/100 Mbit

  2. Under the door are:

    • USB port for firmware update using MyHOME_Suite software *
    • RESET pushbutton (to change to DHCP Dynamic IP keep pressed for 10 s)
    • RS232 serial connection
  3. User interface:

    • Speed: Connection speed: ON = 100 Mbit/s
      OFF = 10 Mbit/s

    • Link: When on, it indicates that the Ethernet network has been found

    • System: On connecting the power supply it switches on and off and the next time it switches on it indicates that MyHOME Server is operative

  4. 2 wire BUS for connection to the MyHOME system

  5. Supplementary power supply (optional) (27 Vdc)

  6. Restart pushbutton:

    • short pressure (1”) = device restart
    • long pressure (10”) = Dynamic IP Setting (D HCP)
      After the long pressure of the reset pushbutton, the system LED will flash twice slowly and twice quickly for about 10”.

NOTE : It is recommended to update the MyHOMEServer1 to the latest available firmware version. The MyHOME_Suite software and the firmware can be downloaded from the website www.homesystems-legrandgroup.com.

Light and Automation Devices that can be directly associated via MyHOME Server

Description| Legrand code| From production batch:| BTicino code| From production batch:|
---|---|---|---|---|---
Scenario control| LG- 573902 __

LG- 573903 __

| 08W51 __

08W51 __

| BT- L4680 __

BT- N4680 __

| 09W08|
09W08|
 | LG- 574503 | all | BT- NT4680 | 09W08|
 | LG- 574504
| all | BT- HC4680 | 09W08|
 | LG- 067217 | all | BT- HD4680 | 09W08|
 | LG- 067218
| all | BT-HS4680| 09W08|
 | LG- 078478
| all |  |  |
 | LG-079178| all|  |  |
SCS/SCS interface| LG-003562| 12W20| BT-F422| 12W20|
Touch multifunction control| LG- 067243

LG- 067244 __

| 13W05 __

13W05 __

|  |
 | LG-067245| 13W05|
BUS 8-key control| LG-067592| all| BT-LN4652 BT-H4652| all|
all|
2 m basic control| LG-067552| all| AR- 64360

BT- H4652/2 __

| 09W40|
09W40|
 |  |  | BT- L4652/2 | 09W40|
 |  |  | BT-AM5832/22| 09W40|
3 m basic control| LG-067554| all| BT- L4652/3

BT- H4652/3 __

| 09W40|
09W40|
 |  |  | BT-AM5832/3| 09W40|
Light actuator|  | BT-K8002L| all|
BUS shutter actuator| LG-067557| all| BT- LN4661M2 __

BT- H4661M2 __

| all|
all|
 |  |  | BT- AM5861M2 | all|
 |  |  | BT-K8002S|
all|
BUS shutter control| LG-067558| all| BT- LN4660M2

BT- H4660M2 __

| all|
all|
 |  |  | BT-AM5860M2| all|
Special control| LG-067553| all| AR- 64362 __

BT- L4651M2 __

| all|
08W41|
 |  |  | BT- H4651M2 | 08W41|
 |  |  | BT-AM5831M2| 08W41|
16A 100/240V 1 relay DIN actuator| LG-003847| all| BT-F411U1| all|
16A 100/240V 2 relay DIN actuator| LG-003848| all| BT-F411U2| all|
16A 100/240V 1 relay DIN actuator| LG-003841| 10W17| BT-F411/1N| 09W13|
16A 2 relay DIN actuator| LG-003842| 10W18| BT-F411/2| 09W04|
16A 100/240V 2 relay DIN actuator| LG-002601| all| BT-BMSW1002| all|
16A 100/240V 4 relay DIN actuator| LG-002602| all| BT-BMSW1003| all|
6A 4 relay DIN actuator| LG-003844| 10W22| BT-F411/4| 09W04|
16A 100/240V 4 relay DIN actuator| LG-002604| all| BT-BMSW1005| all|
4 output DIN actuator for 0-10V ballast| LG-002612| all| BT-BMDI1002| all|
DIN actuator for 0-10V ballast| LG-003656| 10W05| BT-F413N| 09W14|
Basic contact interface| LG-573996| 10W04| BT-3477| 10W04|
DIN contact interface| LG-003553| 10W13| BT-F428| 09W50|
Description| Legrand code| From production batch:| BTicino code| From production batch:
---|---|---|---|---
1000 VA DIN dimmer| LG-002621| all| BT-F416U1| all
1000 W DIN dimmer| LG-003652| 09W50| BT-F414| 09W29
400 VA DIN dimmer| LG-003653| 10W07| BT-F415| 09W22
2 x 400 VA DIN dimmer| LG-002622| all| BT-F417U2| all
300 VA DIN dimmer| LG-003665| all| BT-F418| all
2 x 300 VA DIN dimmer| LG-003651| all| BT-F418U2| all
LG-573912 3 m touch control| LG- 573912
| 11W27 | BT- HC4657M3 | 11W09
 | LG-573913| 11W09| BT- HD4657M3
| 11W12
 |  |  | BT-HS4657M3| 11W12
4 m touch control|  | BT- HC4657M4
| 11W12
 | BT- HD4657M4
| 11W12
 | BT-HS4657M4| 11W14
SCS/DALI interface| LG-002631| 10W13| BT-F429| 10W20
Basic actuator|  | BT-3475| 12W31
BUS shutter DIN actuator| LG-003666| all| BT-F401| all
Control actuator| LG- 067561
| all | BT-AM5852M2| all
 | AR- 64195 | all | BT-H4672M2| all
 | AR- 64196
| all | BT-LN4672M2| all
 | AR-64393| all|  |
Basic control actuator|  | BT-3476| 12W39
Control actuator| LG-067556| all| BT-LN4671M2| all
DIN dimmer for 0-10 V ballast| LG-002611| all| BT-BMDI1001| all
BUS Dual Tech Green Switch| LG- 067226
| all | BT- L4658N | all
 | LG- 078486
| all | BT- N4658N | all
 | LG- 574048
| all | BT- NT4658N | all
 | LG-574098| all| BT- HC4658
| all
 |  |  | BT- HD4658
| all
 |  |  | BT-HS4658| all
PIR BUS automatic switch| LG- 067225
| all | BT- L4659N | all
 | LG- 078485
| all | BT- N4659N | all
 | LG- 574046
| all | BT- NT4659N | all
 | LG-574096| all| BT- HC4659
| all
 |  |  | BT- HD4659
| all
 |  |  | BT-HS4659| all
PIR ceiling mounted sensor| LG-048820| all| BT-BMSE3001| all
PIR+US double technology ceiling mounted sensor| LG-048822| all| BT-BMSE3003| all
IP55 PIR wall mounted sensor| LG-048834| all|
Memory module|  | BT- F425| 10W01
Control|  | BT- K4652M2
| all
 | BT-K4652M3| all
Control actuator|  | BT- K4672M2S
| all __
 | BT-K4672M2L| all

Temperature Control Devices that can be directly associated via MyHOME Server

Description| Legrand code| From production batch:| BTicino code| From production batch:
---|---|---|---|---
Thermostat with Display| LG- 067459 __

LG- 064170 __

LG- 752131 __

LG- 752731 __

| all all all all| BT- LN4691

BT- H4691 __

| all all
Temperature control probe|  | BT- KM4691

BT-KG4691 __ BT-KW4691

| all all all
Probe without adjustment| LG- 067458

LG- 573924 __

LG- 573925 __

| 13W36 __

13W36 __

13W36 __

| BT- L4693 __

BT- N4693 __

BT- NT4693 __

BT- HC4693 __

BT- HS4693 __

BT- HD4693 __

| 13W36 __

13W36 __

13W36 __

13W36 __

13W36 __

13W36 __

DIN actuator with 2 independent relays| LG-003579| 13W06| BT-F430/2| 13W06
DIN actuator with 4 independent relays| LG-003580| 13W06| BT-F430/4| 13W06
DIN actuator with 8 independent relays| LG-003517| all| BT-F430R8| all
DIN actuator with 2 0-10 V outputs| LG-003518| all| BT-F430V10| all
DIN actuator with 3 independent relays and 2 0-10 V outputs| LG-003519| all| BT-F430R3V10| all

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

bticino User Manuals