VIVOTEK FT9361-R Access Control Reader Installation Guide
- June 4, 2024
- Vivotek
Table of Contents
VIVOTEK FT9361-R Access Control Reader
Physical Description
No. | Description | No. | Description |
---|---|---|---|
1 | Display | 2 | NFC induction zone |
3 | Reboot button | 4 | Anti-Force dismantle trigger |
Installation
Bracket Moumnt
-
Themountbracketwillbeavailablelater.
- Secure the back plate to the mount bracket using 4 M3 x 8.0mm screws.
-
Route cables through a hole on the wall or through the bracket. Below are the definitions for these cables.
Lines| Name| Color| Description
---|---|---|---
Line1| GND| Black| GND
12V| Red| 12V input
GND| Brown| GND
12V| White| 12V input
WG_DO| Purple| Wiegand/output DO
GND| Blue| GND
WG_DI| Green| Wiegand/output DO
DC12V_OUT| Orange| 12V output
Line2| Button_HC32| Black| Button for gate open
Senses_HC32| Red| Senses for gate open
Alarm_In_HC32| Brown| Alarm input
GND| White| GND
RS485_A| Purple| RS485 A
RS485_B| Blue| RS485 B
NC| NC| No connection
NC| NC| No connection
Relay_SW3_B| Green| Relay3 B
Relay_SW3_A| Orange| Relay3 A
Line3| NC| NC| No connection
Relay_SW2_B| Black| Relay2 B
Relay_SW2_A| Red| Relay2 A
NC| NC| No connection
Relay_SW1_B| Brown| Relay1 B
Relay_SW1_A| White| Relay1 A
NC| NC| No connection
Relay_Lock_NO| Purple| Relay normally open
Relay_Lock_COM| Blue| Relay normally grand
Relay_Lock_NC| Green| Relay normally close
GND| Orange| GND
NC| NC| No connection
Line4| RJ45| –| RJ45 Ethernet -
Mount the sensor device onto the bracket by sliding it from top down.
-
Secure the installation by driving a screw from the bottom of the back plate.
Login and Registration
Server Configuration
-
Network configuration: When the FT9361-R is started, proceed with network configuration. DHCP or Static IPs are applicable.
-
erver:The FT9361-R requires a connection to a VAST FaceManager server. Click onthe Configuration button on the upper right of screen to configure a VAST Face Managerserver IP. (http://xxx.xxx.xxx.xxx:6073/3rd/vivotek/)
-
hanging Server IP:If you need to change server IP, you need to logout and click the Settings button on the upper right corner of the screen.
Log in to the account
- ogin:On the first startup, credentials are required for a name and password.
Reboot
Press the Reboot button and the machine will reboot.
Setting
Long press the screen enter the Setting modevia Password that you set in
server.
Reset
Long press the screen, select “Reset”, enter the password: Az123567!. Machine
will reset to factory mode.
FCC
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation. Note: This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.