SALTO ESD22Ux Energy Saver Device Instruction Manual

June 15, 2024
SALTO

SALTO ESD22Ux Energy Saver Device

SALTO-ESD22Ux-Energy-Saver-Device-PRODUCT

Product Information

  • Specifications
    • Model: ESDx2UxC
    • Technology: Smart ESD
    • Receiver class : 3
    • Input voltage : 85-265 Vac
    • Frequency: 50/60 Hz
    • Power consumption: To be determined

Product Usage Instructions

  • Electric Panel Protection
    • The ESDx2UxC should be installed in the electric panel of the room. Follow the steps below:
    • Connect the AC input to the L and N terminals.
    • Connect the passage for cables (PASO DE CABLES) to the relevant terminals.
    • If the window detector is not used, do not remove the jumper.
  • Connection Setup
    • To connect the ESDx2UxC, follow these steps:
    • Connect the RS485 bus cables to the IN and OUT ports.
    • Set the jumper to ON or OFF based on your requirements.
    • The communication LED will indicate the status of communication.
  • Optional Placing and Installation
    • If you choose to place the ESDx2UxC on a standard electrical box, follow these steps:
    • Use the recommended holes for placing the device.
    • Ensure proper placement on a 1-gang electrical standard box.
  • Window Detector Function
    • The ESDx2UxC has a window detector function that can be activated. Follow these instructions:
    • Install a window detector and connect it to the right terminal block.
    • Remove the jumper to allow the relay 2 activation to be conditioned to the window being closed.
  • Frequently Asked Questions (FAQ)
    • What is the receiver class of the ESDx2UxC?
    • The receiver class of the ESDx2UxC is 3.
    • What is the input voltage range for the ESDx2UxC?
    • The ESDx2UxC operates with an input voltage range of 85-265 Vac at a frequency of 50/60 Hz.
    • How is the ESDx2UxC configured?
    • The ESDx2UxC is factory-configured to work with any SALTO key and has an activation time of 30 seconds.
    • What is the function of the window detector?
    • The window detector allows the activation of relay 2 to be conditioned on the window being closed. To use this function, install a detector, connect it to the terminal block, and remove the jumper.

INSTALLATION

ESDx 2 U x (C)

SALTO-ESD22Ux-Energy-Saver-Device-FIG-1 \(1\)

MODELS

DIMENSION

SALTO-ESD22Ux-Energy-Saver-Device-FIG-1 \(9\)

WIRING

ESDx 2 U x (C)

  • PROTECTIONS IN THE ROOM ELECTRIC PANEL

  • PASSAGE FOR CABLES

ESDx 2 U x (C)

OPTIONAL PLACING

Use always with electrical standard box

  • Input voltage: 85-265 Vac 50/60 Hz

Consuption:

  • Rest Mode: 100mw (110Vac)// 200mw (220Vac)
  • Relais & Leds bar activated: 1,5w (110Vac) // 1,8w (220Vac)
  • Relays power cut: 10 A (Incandescent and halogen lamps). 12 A (250Vac, cosφ=1) // 8 A (250Vac, cos φ=0,6)
  • Minimal contact current: 100mA@6v
  • Max. section for power and relays contacts connector.
  • Stranded wire section: 12 AWG (2.5 mm²).
  • Strip length: 5.5-6.5 mm.
  • Max. section for windows detector connector.
  • Stranded wire section: 16 AWG (1.5 mm²).
  • Strip length: 4-5 mm.
  • Max. section for RS486 BUS connector.
  • Stranded wire section: 17 AWG (1mm²).
  • Strip length: 5-6 mm.
  • Operating ambient temperature: 0 ° C a 60 ° C.
  • Operating ambient humidity: inferior to 95% without condensation.

Notes:

  • It is mandatory to protect the electric circuits with fuses or magnetotermic switches properly sized.
  • ESD is configured from factory to wok with any SALTO key and with an activation time of 30 seconds.
  • Window detector funtion: Relay 2 activation can be conditioned to “window closed”. For that reason it is necessary to install a detector, connect it to the right terminal block and remove the jumper.
    • CAUTION- Distance between two Energy Savers mod. ESD 8/9xxxx face to face must be minimun of 80 mm.

Declaration of conformity

  • By means of the present Salto Systems S.L. (Pol. Lanbarren C/Arkotz, 9 – 20180 Oiartzun – Spain – CIF B20708517), declares that this equipment fulfills the essential requirements and any other applicable or indispensable dispositions of the Directive 1999/5/CE or the Directive 89/336/EEC.
  • You will be able to find a copy of the original declaration of conformity at the following
  • Internet address: http://www.saltosystems.com.
  • All proximity models are “Receiver class 3”.

All contents current at time of publication. SALTO Systems S.L. reserves the right to change availability of any item in this catalog, its design, construction, and/or materials. P-200693 – -ED.XX/XX/XXXX www.saltosystems.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals