MEAN WELL SE-600 Series 600W Single Output Power Supply User Manual

June 15, 2024
MEAN WELL

MEAN WELL SE-600 Series 600W Single Output Power Supply

MEAN WELL SE-600 Series 600W Single Output Power
Supply

Features

  • AC input active surge current limiting
  • AC input range selected by switch
  • Protections: Short circuit/ Overload/ Over voltage / Over temperature
  • Forced air cooling by built-in DC fan
  • High power density 4.9w/in’
  • Built-in remote sense function
  • UL approved
  • Low cost

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN

SPECIFICATION

MODEL| SE-600-5| SE-600-12| SE-600-15| SE-600-24| SE-600-27| SE-600-36| SE-600-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 100A| 50A| 40A| 25A| 22.2A| 16.6A| 12.5A
CURRENT RANGE| 0 ~ 100A| 0 ~ 50A| 0 ~ 40A| 0 ~ 25A| 0 ~ 22.2A| 0 ~ 16.6A| 0 ~ 12.5A
RATED POWER| 500W| 600W| 600W| 600W| 599.4W| 597.6W| 600W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.75 ~ 5.5V| 10 ~ 13.5V| 13.5 ~ 16.5V| 22 ~ 26.4V| 24 ~ 30V| 32 ~ 40V| 43 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms/230VAC         1000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)| 20ms/230VAC         16ms/115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 132VAC / 180 ~ 264VAC selected by switch 254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 83%| 84%| 87%| 87%| 87%| 88%
AC CURRENT (Typ.)| 12A/115VAC        7.5A/230VAC
INRUSH CURRENT (Typ.)| 30A/115VAC 60A/230VAC
LEAKAGE CURRENT| <2.0mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.3V| 13.8 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 31 ~ 36.5V| 42 ~ 50V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 85℃±5℃ (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to output load derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS**| CB IEC62368-1, UL60950-1,UL62368-1, EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only),

IS13252(Part1)/IEC60950-1(except for 48V) approved; Design refer to BS EN/EN62368-1

WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
OTHERS| MTBF| 1529.1K hrs min. Telcordia TR/SR-332 (Bellcore) ; 204.2K hrs min.

MIL-HDBK-217F (25℃)

DIMENSION| 24712763.5mm (LWH)
PACKING| 2.1Kg; 6pcs/13.4Kg/1.03CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25″C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Tolerance : includes set up tolerance, line regulation and load regulation.

  4. The ambient temperature derating of 3.5°C/1000m with fan less models and of 5°C/1 000m with fan models for operating altitude higher than 2000m(6500ft).

  5. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:
    a ) the end-devices is used within the European Union, and
    b ) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
    c ) the power supply is:

    • installed in end-devices with average or continuous input power greater than 75W, or
    • belong to part of a lighting system
      Exception:
      Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2
      a ) professional equipment with a total rated input power greater than 1 OOOW;
      b ) symmetrically controlled heating elements with a rated power less than or equal to 200W *
      ※Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

Mechanical Specification

AC input terminal :

Pin No. Assignment
1 AC/L
2 AC/N
3 FG

DC Output terminal :

Pin No. Assignment
1~3 +V
4~6 -V

RS Connector (CN4) : JST B-XH or equivalent

Pin No. Assignment Mating Housing Terminal
1 +S JST XHP

or equivalent

| JST SXH-001T

or equivalent

2| -S

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

Static Characteristics

User’s Manual

Symbols

Documents / Resources

| MEAN WELL SE-600 Series 600W Single Output Power Supply [pdf] User Manual
SE-600-5, SE-600-12, SE-600-15, SE-600-24, SE-600-27, SE-600-36, SE-600-48, SE-600 Series 600W Single Output Power Supply, SE-600 Series, 600W Single Output Power Supply, Single Output Power Supply, Output Power Supply, Power Supply, Supply
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals