MODEL| SE-600-5| SE-600-12| SE-600-15| SE-600-24|
SE-600-27| SE-600-36| SE-600-48
---|---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 5V| 12V| 15V| 24V| 27V| 36V| 48V
RATED CURRENT| 100A| 50A| 40A| 25A| 22.2A| 16.6A| 12.5A
CURRENT RANGE| 0 ~ 100A| 0 ~ 50A| 0 ~ 40A| 0 ~ 25A| 0 ~ 22.2A| 0 ~
16.6A| 0 ~ 12.5A
RATED POWER| 500W| 600W| 600W| 600W| 599.4W| 597.6W| 600W
RIPPLE & NOISE (max.) **Note.2| 150mVp-p| 150mVp-p| 150mVp-p|
150mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 4.75 ~ 5.5V| 10 ~ 13.5V| 13.5 ~ 16.5V| 22 ~ 26.4V|
24 ~ 30V| 32 ~ 40V| 43 ~ 56V
VOLTAGE TOLERANCE Note.3| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%|
±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±2.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at
full load
HOLD UP TIME (Typ.)| 20ms/230VAC 16ms/115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 132VAC / 180 ~ 264VAC selected by switch
254 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 78%| 83%| 84%| 87%| 87%| 87%| 88%
AC CURRENT (Typ.)| 12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.)| 30A/115VAC 60A/230VAC
LEAKAGE CURRENT| <2.0mA / 240VAC
PROTECTION| OVERLOAD| 105 ~ 125% rated output power
Protection type : Shut down o/p voltage, re-power on to recover
OVER VOLTAGE| 5.75 ~ 6.3V| 13.8 ~ 16.2V| 18 ~ 21V| 27.6 ~ 32.4V| 31 ~
36.5V| 42 ~ 50V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| 85℃±5℃ (TSW1) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after
temperature goes down
ENVIRONMENT| WORKING TEMP.| -20 ~ +60℃ (Refer to output load
derating curve)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.05%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC| SAFETY STANDARDS**| CB IEC62368-1, UL60950-1,UL62368-1,
EAC TP TC 004, BSMI CNS14336-1, KC K60950-1(for 12V,24V only),
IS13252(Part1)/IEC60950-1(except for 48V) approved; Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
OTHERS| MTBF| 1529.1K hrs min. Telcordia TR/SR-332 (Bellcore) ;
204.2K hrs min.
MIL-HDBK-217F (25℃)
DIMENSION| 24712763.5mm (LWH)
PACKING| 2.1Kg; 6pcs/13.4Kg/1.03CUFT
NOTE|
-
All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25″C of ambient temperature.
-
Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
-
Tolerance : includes set up tolerance, line regulation and load regulation.
-
The ambient temperature derating of 3.5°C/1000m with fan less models and of 5°C/1 000m with fan models for operating altitude higher than 2000m(6500ft).
-
This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:
a ) the end-devices is used within the European Union, and
b ) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and
c ) the power supply is:- installed in end-devices with average or continuous input power greater than 75W, or
- belong to part of a lighting system
Exception:
Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2
a ) professional equipment with a total rated input power greater than 1 OOOW;
b ) symmetrically controlled heating elements with a rated power less than or equal to 200W *
※Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Mechanical Specification
AC input terminal :
Pin No. | Assignment |
---|---|
1 | AC/L |
2 | AC/N |
3 | FG |
DC Output terminal :
Pin No. | Assignment |
---|---|
1~3 | +V |
4~6 | -V |
RS Connector (CN4) : JST B-XH or equivalent
Pin No. | Assignment | Mating Housing | Terminal |
---|---|---|---|
1 | +S | JST XHP |
or equivalent
| JST SXH-001T
or equivalent
2| -S
Block Diagram
Derating Curve
Static Characteristics
User’s Manual
Documents / Resources
| MEAN
WELL SE-600 Series 600W Single Output Power
Supply
[pdf] User Manual
SE-600-5, SE-600-12, SE-600-15, SE-600-24, SE-600-27, SE-600-36, SE-600-48,
SE-600 Series 600W Single Output Power Supply, SE-600 Series, 600W Single
Output Power Supply, Single Output Power Supply, Output Power Supply, Power
Supply, Supply
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>