CWCE EM30 Constant Power LED Emergency Converter Instruction Manual
- October 30, 2023
- CWCE
Table of Contents
EM30 15W/20W/30W ALL IN ONE
CONSTANT POWER LED EMERGENCY CONVERTER
Product Information
This emergency driver is designed for use with the high bay luminaires with integrated LEDs and remote LED drivers. It can be suspended with a luminaire to provide a back-up supply in the event of the power cut. This emergency driver requires a permanent live un-switched supply to maintain the battery charge. In the event of the power cut, the battery will supply the integrated LEDs at rated output.
Features
-
Constant power output
-
For LED modules with a wide rated voltage 30-150VDC
-
Tow gears for adjusting maximum output voltage:60V/150V
-
Three gears for adjusting emergency power: 15W/20W/30W
-
Wireless remote control for emergency testing
-
For high bay luminaires with integrated LEDs and remote LED drivers
-
Maintenance of emergency lighting system
-
Conforms to EN 61347-1,EN 61347-2-7 and EN 61347-2-13
-
Equipped with IP68 certified water-proof connector
-
Automatically starts to work during voltage fluctuation and flicker.
-
1.5/2/3 hours rated duration
-
Over-charge, over-current, short-circuit and deep discharge protection for battery
-
Test button for a quick functional test
-
Design life:
8 years @ 25°C max ambient temperatures.
6 years @ 35°C max ambient temperatures.
4 years @ 45°C max ambient temperatures. -
Warranty 3 years.
Model List
Model No.| Input Voltage| Output Power| Test Mode|
Charge Time| Discharge Duration| Battery
---|---|---|---|---|---|---
EM30-180A/B-6Ah-LFP| 220-240VAC| 15W| MT/AT| 24H| 180Mins| LiFePO4 12.8V 6Ah
EM30-120A/B-6Ah-LFP| 220-240VAC| 20W| MT/AT| 24H| 120Mins| LiFePO4 12.8V 6Ah
EM30-090A/B-6Ah-LFP| 220-240VAC| 30W| MT/AT| 24H| 90Mins| LiFePO4 12.8V 6Ah
Specifications
EM30-180A-6Ah-LFP | EM30-120A-6Ah-LFP | EM30-090A-6Ah-LFP | |
---|---|---|---|
Output Power | 15W | 20W | 30W |
Discharge Duration | 180Mins | 120Mins | 90Mins |
Input Voltage | 220-240VAC,50/60Hz | 220-240VAC,50/60Hz | 220-240VAC,50/60Hz |
Input Current | 100mA Max. | 100mA Max. | 100mA Max. |
Power factor | 0.5 | 0.5 | 0.5 |
Output Voltage | 30-60VDC | 30-60VDC | 30-60VDC |
Output Current | 250-500mA | 330-670mA | 500-1000mA |
Battery | LiFePO4 12.8V 6Ah | LiFePO4 12.8V 6Ah | LiFePO4 12.8V 6Ah |
Charge Time | 24H | 24H | 24H |
Test Mode | MT/AT | MT/AT | MT/AT |
IP Rating | IP65 | IP65 | IP65 |
Ambient Temperature | 0°C-45°C | 0°C-45°C | 0°C-45°C |
EM30-180B-6Ah-LFP | EM30-120B-6Ah-LFP | EM30-090B-6Ah-LFP | |
Output Power | 15W | 20W | 30W |
Discharge Duration | 180Mins | 120Mins | 90Mins |
Input Voltage | 220-240VAC,50/60Hz | 220-240VAC,50/60Hz | 220-240VAC,50/60Hz |
Input Current | 100mA Max. | 100mA Max. | 100mA Max. |
Power factor | 0.5 | 0.5 | 0.5 |
Output Voltage | 60-150VDC | 60-150VDC | 60-150VDC |
Output Current | 100-250mA | 130-330mA | 200-500mA |
Battery | LiFePO4 12.8V 6Ah | LiFePO4 12.8V 6Ah | LiFePO4 12.8V 6Ah |
Charge Time | 24H | 24H | 24H |
Test Mode | MT/AT | MT/AT | MT/AT |
IP Rating | IP65 | IP65 | IP65 |
Ambient Temperature | 0°C-45°C | 0°C-45°C | 0°C-45°C |
Wiring diagram
System Status indication
TEST | LED indicator | LED indication | System Status |
---|---|---|---|
AT | Greenpermanent | Power on and System OK | |
Greenspoon flash (4s on, 1s off) | Charging | ||
Red Slow flash (4s on, 1s off) | Duration tested 5days indication following |
completion of test
| Red medium flash (1s on, 1s off)| Function test
| Red fast flash once, then pause (o.5s on, 0.5s off, 4s pause)| Battery not
connected or
short-circuited
| Fast flash twice, then pause (o.5s on, 0.5s off, 4s pause)| Low battery
capacity
| Fast flash 3 times, then pause (o.5s on, 0.5s off, 4s pause)| Charge circuit
fault
| Fast flash 4 times, then pause (o.5s on, 0.5s off, 4s pause)| LED driver
circuit fault
| Fast flash 4 times, then pause (o.5s on, 0.5s off, 4s pause)| LED lamp fault
| Green and Red Off| Power off
Notes: After repairing a service fault, press and hole the test button for
more than 2 seconds to reset the flashing indicator light to green.
MT| Green| Permanent| Normal standby mode or charging
Green| Off| Power off or battery fault
Remote Control Operation Instructions
D. Other parameters
- Use 433MHz transmission and reception frequency, not easily interfered.
- Remote control direction 360 degrees without dead angle, not easy to block.
- Super power transmitting and receiving antenna, remote control distance is longer, linear remote control distance 20-50M.
- No need to learn, use one-to-many control mode, one remote control can control all emergency lamps.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>