CO-Z 1400LBS 600KG Automatic Sliding Gate Opener
Product Information
Specifications
- Maximum weight of gate: 600KG (1400Lbs)
- Power supply: 110V/60Hz
- Motor power: 280W
- Gate moving speed: 40ft/min
- Remote control distance: 30m(10ft)
- Remote control mode : Single button mode
- Limit switch: Magnetic limit switch
- Noise: 58dB
- Working duty: S2, 15min
- Recording of up remote controls: 20
- Frequency: 433.92 MHz
- Working temperature: N/A
- Package weight: 34.4Lbs
- Size of embedded hole: N/A
Product Usage Instructions
Installation Procedures
Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail
is horizontal, and the gate can glide back and forth smoothly when moved by
hands before installing the gate opener.
Cable installation
Please bury the motor & power cable and controlling cable with PVC tube,
and use two PVC tubes to bury (motor & power cable) and (controlling cable)
separately, so as to guarantee normal operation of the gate opener and protect
the cables from damages.
Concrete pedestal
Please cast a concrete pedestal with the size of 19.69inch x 13.78inch and
depth of 7.87inch in advance, so as to firmly install the gate opener. Please
verify whether the distance between the gate and gate opener is suitable
before casting the pedestal.
Main engine installation
- Dismantle the plastic housing on the main engine before installation and keep relevant fasteners properly.
- Assemble the detachable mounting base.
- Attach the flat washer, spring washer, and nut M6 to the horizontal mounting plate.
- Attach the horizontal mounting plate to the main engine using the embedded screws.
- Attach the vertical mounting plates to the main engine using the embedded screws.
FAQ (Frequently Asked Questions)
What is the maximum weight limit for the sliding gate opener?
The maximum weight limit for the sliding gate opener is 600KG (1400Lbs).
What is the power supply requirement for the gate opener?
The gate opener requires a power supply of 110V/60Hz.
What is the remote control distance?
The remote control distance is 30m (10ft).
How many remote controls can be recorded for the gate opener?
The gate opener can record up to 20 remote controls.
Dear users,
Thank you for choosing this product. Please read the manual carefully before
assembling and using it. Please do not leave out the manual if you send this
product to a third party.
Safety Instruction
- Please ensure that the using power voltage matches with the supply voltage of gate opener (AC110V ); kids are forbidden to touch the control devices or the remote-control unit.
- The remote-control unit is controlled by a single button mode. The indicator light on the remote-control unit will flicker when the button on it is pressed. Main engine and gate can be unlocked by disengagement wrench and the gate can move with manual operation after disengagement.
- Please ensure that no one is around the main engine or gate when the switch is operated and it is usually demanded to examine the stability of installation.
- Please temporarily stop using if the main engine needs repairing or regulation.
The installation and maintenance of the products must be carried out by professionals.
Packing List
Technical parameters
This sliding gate opener is applicable to gate weight less than 600kg (1400Lbs), and length of the sliding gate should be less than 30ft. This gate opener must be installed inside the enclosure or yard for protection.
Maximum weight of gate | 600KG (1400Lbs) |
---|---|
Power supply | 110V/60Hz |
Motor power | 280W |
Gate moving speed | 40ft/min |
Remote control distance | ≥ 30m(10ft) |
Remote control mode | Single button mode |
Limit switch | Magnetic limit switch |
Noise | ≤58dB |
Working duty | S2, 15min |
Recording of up remote controls | 20 |
Frequency | 433.92 MHz |
Working temperature | -20°C ~ +70°C |
Package weight | 34.4Lbs |
Installation procedures
Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail is
horizontal, and the gate can glide back and forth smoothly when moved by hands
before installing the gate opener.
Cable installation
Please bury the motor & power cable and controlling cable with PVC tube, and
use two PVC tubes to bury (motor & power cable) and (controlling cable)
separately, so as to guarantee normal operation of the gate opener and protect
the cables from damages.
Concrete pedestal
Please cast a concrete pedestal with the size of 19.69inch x 13.78inch and
depth of 7.87inch in advance, so as to firmly install the gate opener. Please
verify whether the distance between the gate and gate opener is suitable
before casting the pedestal.
Main engine installation
- a ) Dismantle the plastic housing on the main engine before installation and keep relevant fasteners properly;
- b ) assemble the detachable mounting base;
- c ) Assemble the machine engine to the mounting base;
- d ) Please prepare the power line for connecting mounting plate and main engine (the number of power supply cable core shall not be less than 3 PCS, the sectional area of cable core shall not be lower than 1.5mm² and the length shall be determined by users according to the field situation) due to different installation environments;
- e ) Please unlock the main engine before installation, the unlock method is: take out the key cover, insert the key, and open the manual release bar till it rotates by 90°. Then turn the output sprocket and the sprocket can be rotated easily;
Chain installation
Close the gate; connect the tie rod with chain through chain link; fasten the
tie rod to the door connecting plate by washers and nuts . If necessary, the
chain can be shortened. If it need to be lengthened, make sure to use same
type of chain. (US standard NO.41).
- Use the round screws when the door frame is round; Use the square screws when the door frame is square.
- Install the chain and sprocket cover as shown in the figure.
- The distance between main engine and chain ends should be at least 11.81inch (30cm):
Warnings
- To ensure safety, install safety stopblocks on both ends of the rails to prevent the gate out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place and that it has the function of preventing the gate from moving out of the rail and out of the safety range.
- Please ensure that the main engine and its components have good mechanical properties, and the gate can operate flexibly when moved by hand before installing the main engine.
- In this product, one control can drive one main engine only, otherwise, the control system will be damaged.
- Earth leakage circuit breaker must be installed where the gate movement can be seen, and the minimum mounting height is 4.92ft to protect it from being touched.
- After installation, please check whether the mechanical property is good or not, whether gate movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is installed correctly and effectively.
Limit switch adjustment
Use the manual release key to unlock the gate opener and manually move the
gate to the predetermined position; fix the magnetic limit switch block and
close the clutch; testing run after power on, slightly adjust the position of
the magnetic limit switch block until the gate reaches the desired open and
close limit location. Installation of magnetic limit switch bock (97mm =
3.82inch 35mm = 1.38inch, 20mm = 0.79inch)
Control board
Connections and Indicators Diagram
Connection | Interface Terminals |
---|---|
Power | X4:PE, N, L |
Caution/Alarm Lamps | X2:D1, D2 |
External Button | X5: COM, OSC |
Photocell Infrared Sensor | X6: 24VDC, GND, I.R |
Features
- Pair with up to 20 different 433.92 MHz remote controls and with wireless keypads.
- Compatible with and easily connected to alarm lamps, external control buttons, and infrared photocell sensors.
- Auto-close functionality for improved security.
Gate Opener Installation
-
Step 1
Ensure your gate can glide back and forth smoothly by hand before installing the gate opener. -
Step 2
Toggle the Travel Direction Switch on the control board according to the installation location of your automatic gate opener. Flip the switch to FWD for right-mounted gate openers. Flip the switch to REV for left-mounted gate openers. -
Step 3
Wire the control board to your automatic gate opener and any compatible accessories according to the Connections and Indicators Diagram in the Product Overview section of this manual and the instruction manuals for the other devices. -
Step 4
Press the test button, Travel direction indicator (open) will light when the gate is opening; Travel direction indicator (close) will light when the gate is closing.
Remote Control
The included remote control uses single-button mode. Each button on the remote
control can pair with one control board. When pressed, the paired button will
open the gate if the gate is closed, close the gate if the gate is open, and
stop the gate if the gate is traveling.
CAUTION : To prevent accidents, DO NOT pair one button with two different
control boards. The transmitter has been matched to the door opener when it
leaves the factory, No need to match again when the product is received.
Remote Control Pairing:
-
Step 1
Press the Remote Pair Button (AN1) on the control board. The Remote Signal Indicator (LED2) will come on. -
Step 2
Press the button on the remote control to be paired. The Remote Signal Indicator will go off. -
Step 3
Press the same button the remote control. The Remote Signal Indicator will flash quickly then go off. DONE!
Remove All Paired Remote Controls:
Hold Remote Pair Button (AN1) on the control board until the Remote Signal
Indicator (LED2) goes out. DONE!
DIP Switches
The DIP switches on the control board control the external buttons control
mode and the auto-close time settings.
- Switch 1 : External Buttons Settings
- ON = external button only can open the gate
- OFF = external button can open/stop/close the gate
Switches 2 & 3: Auto-Close Time Settings
Switch Orientations | Auto-Close Time |
---|---|
2 ON 3 OFF | 15 seconds |
2 OFF 3 ON | 30 seconds |
2 OFF 3 OFF | 45 seconds |
2 ON 3 ON | Auto-Close Disabled |
Photocell Infrared Sensor Installation
-
Step 1
Remove the short wire connecting the I.R and GND interface terminals on the control board. -
Step 2
Install the photocell infrared sensor on your gate posts according to the instructions for your photocell infrared sensor. -
Step 3
Connect the sensor to the control board according to the image below.
Troubleshooting
Problems
|
Possible Reasons
|
Solutions
---|---|---
The gate cannot open or close normally, and the LED does not light.| 1. The
power is off.
2. Fuse is burned.
3. Control board power wiring
with problem.
| 1. Switch on the power supply.
2. Check the fuse (code FU), and change the fuse if burnt.
3. Re-wiring according to instructions.
The gate can open but cannot close.| 1. Photocell wiring with problem. 2. Photocell mounting with problem.
3. Photocell is blocked by objects.
4. The sensitivity of the obstacle is too high (Intelligent type).
5. Hall switch parts is damaged (Intelligent type).
| 1. If not connected photocell, please make sure that the infrared port and GND short circuit; if connected infrared sensor, please make sure the wiring is correct and the photocell is N.C.
2. Make sure that the photocell mounting position can be mutually aligned.
3. Remove the obstacle.
4. Reduce the sensitivity of obstacles.
5. Change hall switch parts.
Remote control doesn’t work.| 1. The battery level of the remote control is low.
2. Remote control learning is not completed.
| 1. Change the remote control battery.
2. Re-conduct remote control learning.
Press the OPEN and CLOSE buttons, the gate is not moving, motor makes a
noise.| 1. Capacitor is broken.
2. The capacitor is poorly connected. 3. Gate moving is not smooth.| 1.
Change capacitor.
2. Check the capacitor wiring.
3. According to the actual situation adjust the motor or the gate.
Not stop at the limit position when opening / closing.| 1. The limit direction is wrong.
2. The mounting of the magnetic limit switch with the problem.
| 1. Check whether the limit switch wiring is consistent with the actual direction of operation.
2. Check whether the distance between the magnetic limit switch and motor, and the height of the magnetic limit switch can reach the mounting requirement.
The leakage switch tripped.| Power supply line short circuit or motor line
short circuit.| Check wiring.
The remote control working distance is too short.| The signal is blocked.|
Connect external receiver antenna, 1.5 meters above ground.
Contact Us
Thank you for choosing our products! If you have any questions or comments,
contact us at help@cs-supportpro.com and
we’ll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the appropriate app on your smartphone to scan the QR code to the right.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>