- SOYAL AR-401-IO-1608R WEB PLC and Expansion I-O Module
- Contents
- Features
- Specification
- Installation(mm)
- PIN Assignments
- Module I/O (16 Optical Isolation Input / 8 Relay Output)
- Wiring Diagram
- Feature Introduction
- Software Setting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SOYAL AR-401-IO-1608R WEB PLC and Expansion I-O Module
Contents
Product
Features
- Support for a high-security centralized access control system with separation of reading and control.
- Supports Modbus and SOYAL communication protocols, suitable for various IoT integration applications.
- Built-in input optocoupler protection function, effectively achieving electrical isolation, high voltage protection, lightning resistance, and avoiding noise interference.
- Versatile application modes: standard I/O, multi-door interlock, people counting, crowd control, etc., easily meeting various application scenarios.
- Compatible with Modular DIN Rail Mounting Base (AR-701B)
Specification
Interface | Serial port | RS485 X 1 port |
---|---|---|
Baud Rate | 9600,19200 bps (N,8,1) | |
Input/Output | 16 Digital Input / 8 Relay Output (Form C) | |
Protocol | Modbus, Soyal protocol | |
LED Indicator | Power,Tx/Rx, D.O./D.I | |
Watchdog function | Yes | |
Operating Temperature | -20℃ ~ +70℃ | |
Fuses | Power and RS485 Isolation protection | |
Noise Isolation | Input optical isolation | |
Power Supply | 9-24 VDC | |
Power Consumption | <4W |
Dimension(mm)
| PCB:117(H)x148(W)x20(D)
Panel Mounting Base :117(H)x175(W)x30(D) Metal Box:180(H)x231(W)x62(D)
Weight(g)| 100±10(PCB Only)
Installation(mm)
PIN Assignments
CN1
Function | Pin | Description |
---|---|---|
Main Power Supply (Single Power Supply Mode) (DC12V/1W) | 1 | V+ |
2 | V- |
CN2
Function | Pin | Description |
---|
External Port 1
(RS-485 input)
| 1| L1-(B-)
2| L1+(A+)
CN3~10
Function | Pin | Description |
---|---|---|
Relay output 1~8 | 1 | N.O. |
2 | COM | |
3 | N.C. |
- 701ClientSQL Graphic Animation I/O mapping starts from 00(Physical IO Address DI1 –>Symbol IO Nr.:00, Physical IO Address DI16 –>Symbol IO Nr.:15
CN11
Function | Pin | Description |
---|---|---|
DI input | 1 | DI.1 |
2 | DI.2 | |
3 | DI.3 | |
4 | DI.4 | |
5 | COM |
CN12
Function | Pin | Description |
---|---|---|
DI input | 1 | DI.5 |
2 | DI.6 | |
3 | DI.7 | |
4 | DI.8 | |
5 | COM |
CN13
Function | Pin | Description |
---|---|---|
DI input | 1 | DI.9 |
2 | DI.10 | |
3 | DI.11 | |
4 | DI.12 | |
5 | COM |
CN14
Function | Pin | Description |
---|---|---|
DI input | 1 | DI.13 |
2 | DI.14 | |
3 | DI.15 | |
4 | DI.16 | |
5 | COM |
Module I/O (16 Optical Isolation Input / 8 Relay Output)
DIP Switch Setting
Standard Firmware
Interlock Door Solution
Wiring Diagram
Wiring Method for High-Security Mode
Feature Introduction
- The high-security mode architecture offers several advantages:
- Power Failure Continuation: A backup mechanism for uninterrupted operation during power outages.
- Centralized Control: Electric locks, open door buttons, and door position detection are all centralized in the equipment room, reducing the risk of I/O control leakage.
- Advanced Anti-Tailgating: Support for interlock control of up to 8 doors to prevent unauthorized entry.
Wiring Diagram
Door Name
| Channel 1| Channel 2| Common Contact
---|---|---|---
Lock| Push Button| Door Sensor| Controller
Door A| DO1| DI1| DI2| Node ID 009| ****
Fire Alarm
Door B| DO2| DI3| DI4| Node ID 010
Door C| DO3| DI5| DI6| Node ID 011
Door D| DO4| DI7| DI8| Node ID 012
Door E| DO5| DI9| DI10| Node ID 013
Door F| DO6| DI11| DI12| Node ID 014
Door G| DO7| DI13| DI14| Node ID 015
Door H| DO8| DI15| DI16| Node ID 016
Software Setting
Setting Method
- STEP 1: Select in 701ServerSQL.
- STEP 2: Click ” 721E16/Ev5 “
- STEP 3: Check the required functions for RS-485 card readers with station numbers 09 to 16 on CH2.
- When CH1 is connected to the I/O expansion board, it is necessary to deselect station numbers 01 to 08.
| 701ServerSQL Screen Names| Function Description
---|---|---
1| Anitipa| Anti-pass-back
2| Indoor| Entry/Exit Reader
3| Egress| Exit by Push Button
4| TimeAt| Entry and Exit Access is recorded on the Duty Report
5| ForceA| Enable force Open trigger alarm
6| Relok| Activate close door automatically lock (Auto-Relock)
7| OpenZo| Auto Open
Read User Manual Online (PDF format)